Plan Review Details - Permit 02040091
Plan Review Stops For Permit 02040091 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2002-05-09 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-05-01 |
Time |
15:34 |
Rev Time |
3.00 |
Received By |
lhatten |
Date |
2002-05-05 |
Time |
19:42 |
Sent To |
|
|
Notes |
2002-05-09 00:00:00 | REVIEW & STAMPED PLANS 05/05/2002 | | CALC. FEES & PRINT CARDS 05/09/2002 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2002-05-01 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-05-01 |
Time |
15:34 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2002-05-01 |
Time |
15:34 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2002-04-25 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-04-25 |
Time |
12:11 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2002-04-25 |
Time |
12:11 |
Sent To |
P |
|
Notes |
2002-04-25 00:00:00 | ****************** UNSAT *************** | | | | 1)NOTE: PLEASE NOTE THAT THE WRONG CODES | | ARE REFERENCED. 96 NEC SHOWN AND WE ARE | | UNDER THE 99 NEC. PLEASE CORRECT. | | | | 2)NOTE: PLEASE THAT THE AIC RATING IS | | SHOWN AS 22.00 INSTEAD OF 22,000 AIC. | | A MISPRINT. | | | | 3 )NOTE: PLEASE CLARIFY EQUIPMENT | | GROUNDING METHOD BETWEEN FIRST MEANS | | OF DISCONNECT AND PANELS. PLEASE SIZE | | CONDUCTORS PER 250-122. | | | | 4))NOTE: PLEASE LIST THE REQ`D ARC | | FAULT PROTECTED CIRCUITS. | | SCHEDULE. PER 210-12 | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE AREANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2002-11-30 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2002-11-30 |
Time |
07:19 |
Rev Time |
0.50 |
Received By |
hmoser |
Date |
2002-11-30 |
Time |
07:19 |
Sent To |
|
|
Notes |
2002-11-30 00:00:00 | PASS/PROVISO | | 1) NEED NEW ENERGE CALCULATIONS & | | MANUAL (J) FOR FINAL | | PLAN REVIEW BY HAROLD MOSER | | (561)659-8096 EXT.8390 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2002-05-09 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2002-05-09 |
Time |
17:30 |
Rev Time |
0.50 |
Received By |
hmoser |
Date |
2002-05-09 |
Time |
17:30 |
Sent To |
|
|
Notes |
2002-05-09 00:00:00 | PRIVISO | | NEED DUCT SIZE FOR RISER 10 IN OR 14 IN | | BEFOR ROUGH INSPECTION | | H.M. 5/9/02 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2002-04-24 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2002-04-24 |
Time |
17:14 |
Rev Time |
0.33 |
Received By |
hmoser |
Date |
2002-04-24 |
Time |
17:14 |
Sent To |
|
|
Notes |
2002-04-24 00:00:00 | PLAN DENIED | | #1 MANUAL J AND PLANS DO NOT MATCH | | #2 REFER TO SECTION 402 OR403 2001 | | FLORIDA BUILDING CODE | | #3 REFER TO SECTION 601.4 FBC.2001 | | PLAN REVIEW BY HAROLD MOSER | | [561]659-8096 EXT 8390 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2002-04-27 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-04-25 |
Time |
13:34 |
Rev Time |
0.33 |
Received By |
jleech |
Date |
2002-04-27 |
Time |
10:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2002-04-08 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2002-04-08 |
Time |
07:55 |
Rev Time |
0.25 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
|