Plan Review Details - Permit 02031469
Plan Review Stops For Permit 02031469 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2002-06-18 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2002-06-18 |
Time |
10:18 |
Rev Time |
0.25 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2002-06-18 00:00:00 | REVISION; WIRE MESH SLAB SUPPORT |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2002-05-17 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2002-05-17 |
Time |
13:25 |
Rev Time |
2.00 |
Received By |
jwitmer |
Date |
2002-05-17 |
Time |
13:24 |
Sent To |
|
|
Notes |
2002-05-17 00:00:00 | PROVISO: | | PERMIT 02031469 | | 2881 N BIGHT | | | | 1)FL BLDG 1909.3 (EXEPTION# 2) | | CONCRETE SLABS ON GRADE CONTAINING 6X6/ | | W1.4XW1.4 WELDED WIRE REINFORCEMENT | | FABRIC LOCATED IN THE MIDDLE TO THE | | UPPER 1/3RD OF THE SLAB SHALL BE SUP- | | PORTED BY APPROVED MATERIALS OR SUPPORTS | | AT SPACING NOT TO EXCEED 3 FT OR IN | | ACCORDANCE WITH MANUFACTURER'S SPEC. | | ANY QUESTIONS PLEASE CALL, | | JIM WITMER | | BUILDING PLAN REVIEW | | DEPARTMENT OF CONSTRUCTION SERVICES | | CITY OF WEST PALM BEACH | | (561) 659-8096 EXT. 8412 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2002-04-16 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2002-04-16 |
Time |
11:37 |
Rev Time |
2.00 |
Received By |
jwitmer |
Date |
2002-04-16 |
Time |
11:37 |
Sent To |
|
|
Notes |
2002-04-16 00:00:00 | BUILDING PLAN REVIEW | | PERMIT # 02031469 | | 2881 N BIGHT | | CONT: ENGLE HOMES | | TEL: 968-5671 | | | | FL BLDG CODE= 2001 FLORIDA BUILDING CODE | | | | 1)- PLANS SUBMITTED AFTER FEB 28, 2002 | | SHALL BE REVIEWED UNDER THE 2001 FLORIDA | | CODE. | | 2)- SHEET #1 TO INDICATE DESIGNED TO FL | | BLDG CODE. FL BLDG CODE 1606.1.7 INFOR- | | MATION REQUIRED FOR WIND SHALL BE ON THE | | CONSTRUCTION DRAWINGS | | 3)- FL BLDG CODE 1909.3 (EXCEPTION# 2) | | CONCRETE SLABS ON GRADE ON GRADE CONTAIN | | ING 6X6/ W1.4XW1.4 WELDED WIRE REINFORCE | | MENT FABRIC TO BE LOCATED IN THE MIDDLE | | TO UPPER 1/3RD OF THE SLAB SHALL BE SUP- | | PORTED BY APPROVED MATERIALS OR SUPPORTS | | AT SPACING NOT TO EXCEED 3'-0" OR IN | | ACCORDANCE WITH MANUFACTURES SPEC. | | 4)- ANCHOR SCHEDULE: | | B TYPE ANCHOR 1383 LBS UPLIFT. THE SIMPS | | ON HETAL CONNECTION WITH (15) #10D NAILS | | WITH 112LBS SHEAR= 1680 "OK". WHEN THE | | SAME 112LBS SHEAR IS APPLIED TO (5)#10'S | | =560LBS NOT THE 1383REQUIRED? IT IS NOT | | CLEAR IF THE TA & TAR COMBINED WITH | | (10) 10D@112=1120 LBS, STILL SHORT THE | | 1383. | | 5)- TRUSS ENGINEERING IS DESIGNED TO | | 110MPH NOT THE 140 MPH. | | | | BUILDING PLAN REVIEW | | JIM WITMER | | (561)659-7096X8412 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2002-04-09 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2002-04-09 |
Time |
07:49 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2002-04-09 |
Time |
07:10 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2002-08-02 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2002-08-02 |
Time |
10:59 |
Rev Time |
0.35 |
Received By |
pkrauss |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2002-08-02 00:00:00 | MECHANICAL PERMIT 02031527 | | REVISION |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2002-04-13 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2002-04-13 |
Time |
08:17 |
Rev Time |
0.33 |
Received By |
hmoser |
Date |
2002-04-13 |
Time |
08:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2002-04-11 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2002-04-09 |
Time |
07:49 |
Rev Time |
0.33 |
Received By |
jleech |
Date |
2002-04-11 |
Time |
14:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2002-04-03 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2002-04-03 |
Time |
13:54 |
Rev Time |
0.25 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy