Plan Review Details - Permit 02030614
Plan Review Stops For Permit 02030614
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-05-02 Cont ID  
Sent By btrobaug Date 2002-05-02 Time 14:10 Rev Time 0.00
Received By btrobaug Date 2002-05-02 Time 13:49 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2002-04-02 Cont ID  
Sent By btrobaug Date 2002-04-02 Time 14:00 Rev Time 0.00
Received By btrobaug Date 2002-04-02 Time 12:59 Sent To R
Notes
2002-04-02 00:00:00***************** FAILED ***************
  
 1} PLEASE SUBMIT AIC RATINGS FOR
 ALL NEW EQUIPMENT BEING INSTALLED.
 MAINS/PANELS/BREAKERS MUST BE RATED FOR
 THE AVAILABLE FAULT CURRENT PER 110-9.
  
 2} PLEASE LIST THE REQ`D BATH(S)
 CIRCUIT(S) PER 210-11-C-3.
 MUST BE 20A AND #12AWG.
  
 3} ALL BEDROOMS TO BE PROTECTED BY
 A.F.C.I. PER 210-12.
  
 4} KITCHEN ISLAND RECEPTACLES PER
 210-8(A)(6).
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/659-8096EXT.8392

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-05-09 Cont ID  
Sent By hmoser Date 2002-05-09 Time 16:47 Rev Time 0.50
Received By hmoser Date 2002-05-09 Time 16:47 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2002-03-30 Cont ID  
Sent By btrobaug Date 2002-05-02 Time 14:10 Rev Time 0.33
Received By hmoser Date 2002-03-30 Time 13:05 Sent To  
Notes
2002-03-30 00:00:00PLAN DENIED
 NO DUCT SIZE ON PLAN.
 PLAN REVIEW BY HAROLD MOSER
 [561]659-8096 EXT 8390

Review Stop P PLUMBING
Rev No 2 Status P Date 2002-09-26 Cont ID  
Sent By kstevens Date 2002-09-26 Time 18:00 Rev Time 0.00
Received By kstevens Date 2002-09-26 Time 18:00 Sent To  
Notes
2002-09-26 00:00:00REVISION OK - SANT. RISER DIAGRAM

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-03-30 Cont ID  
Sent By jleech Date 2002-03-30 Time 07:28 Rev Time 0.33
Received By jleech Date 2002-03-30 Time 07:28 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2002-05-09 Cont ID  
Sent By lhatten Date 2002-05-09 Time 17:47 Rev Time 0.50
Received By lhatten Date   Time   Sent To  
Notes
2002-05-09 00:00:00CALC. FEES & PRINT CARDS 05/09/2002

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2002-05-08 Cont ID  
Sent By btrobaug Date 2002-04-02 Time 14:13 Rev Time 3.00
Received By lhatten Date 2002-05-05 Time 17:58 Sent To  
Notes
2002-05-08 00:00:00REVIEW & STAMPED PLANS & TRUSS ENG.
 05/05/2002

Review Stop Z ZONING
Rev No 1 Status P Date 2002-03-18 Cont ID  
Sent By sgraham Date 2002-03-18 Time 08:02 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy