Plan Review Details - Permit 02030439
Plan Review Stops For Permit 02030439
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2002-07-25 Cont ID  
Sent By lsmith Date 2002-07-25 Time 14:18 Rev Time 0.25
Received By lsmith Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2002-05-01 Cont ID  
Sent By lsmith Date 2002-05-01 Time 10:42 Rev Time 0.50
Received By lsmith Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-04-03 Cont ID  
Sent By btrobaug Date 2002-03-29 Time 11:22 Rev Time 0.50
Received By lsmith Date   Time   Sent To  
Notes
2002-04-03 00:00:00*****************FAILED****************
  
 1. POOL SAFETY REQUIREMENTS ACCORDING
 TOTHE FBC2001 CHAPTER 4 SECTION 424:
 REQIDENTIAL PRIVATE SWIMMING POOLS
  
 2. PLANS MUST SHOW THE DETAIL FOR THE
 CONCRETE EQUIPMENT PAD & TYPE /METHOD OF
 ANCHORING EQUIPMENT.
  
 3. GENERAL NOTES: CODE REFERENCE IS:
 FBC:2001.THIS MUST BE SHOWN ON THE
 PLANS. ANY REFERENCE TO OTHER CODES
 WILL NOT BE ACCEPTED.
  
  
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH, BUILDING PLANS EXAMINER
 659-8096 EXT. 8394

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-03-29 Cont ID  
Sent By kstevens Date 2002-03-29 Time 09:24 Rev Time 0.00
Received By btrobaug Date 2002-03-29 Time 10:24 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2002-04-24 Cont ID  
Sent By kstevens Date 2002-04-24 Time 18:42 Rev Time 0.00
Received By kstevens Date 2002-04-24 Time 18:42 Sent To Z
Notes
2002-04-24 00:00:00 
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-03-29 Cont ID  
Sent By kstevens Date 2002-03-29 Time 09:10 Rev Time 0.00
Received By kstevens Date 2002-03-29 Time 09:10 Sent To E
Notes
2002-03-29 00:00:00 
  
  
  
 DENIED
 REFERENCE: FBC-2001 POOL CODE
  
 1) GENERAL NOTES #14 PER FBC-2001 SEC
 4.24.2.6 DESIGN PER THIS SEC NOT WPB
 SWIMMING CODE.
 2) POOL DATA & EQUIPMENT - DESIGN FBC
 4.24.2.6 NOT SEC 104.1 2001 EDT.
 3) SEC 4.24.2.6.6.2 PROVIDE MANUF. SHEET
 FOR APPROVAL ON VAC LOC FOR VACUUM LINE.
 (IF HAYWARD W400AWHP STATE ON PLANS)
 4) SEC 4.24.2.7.2 PROVIDE MOUNTING DE-
 TAIL FOR EQUIPMENT. SLAB TO BE NOMINAL
 4" SLAB, (TO BE SHOWN ON DETAIL).
 5) SEC 4.24.2.9 WATER SUPPLY - UTILITY
 ORD. 2853-95 BACKFLOW REQUIRED ON WATER
 SERVICE. (STATE ON PLANS)
 6) SEC 4.24.2.12 PRESSURE TEST - NO AIR
 TEST ALLOWED FOR PVC. (STATE ON PLANS)
 7) SEC 4.24.13.2 JOINTS AND CONNECTIONS,
 PURPLE CLEANER REQUIRED FOR PVC PER
 FBC-2001 PLUMBING SEC 605.21 (STATE ON
 PLANS)
 8) FOR FUTURE INFORMATION - WHEN HEATER
 WILL BE USED SEE SECTIONS 4.24.2.6.4,
 SUBMIT MANUF. RECOMMENDATIONS, AND SEC
 4.24.2.14.2 WATER RETENTION, SHOW HOW
 WATER WILL BE RETAINED, AND SECION
 4.24.2.14.4 CONNEDTIONS FOR HEATER SHALL
 BE BY UNIONS OR FLANGES.(STATE ON PLANS)
  
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop Z ZONING
Rev No 1 Status P Date 2002-03-18 Cont ID  
Sent By kstevens Date 2002-04-24 Time 19:11 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***