Plan Review Details - Permit 02021928
Plan Review Stops For Permit 02021928
Review Stop B BUILDING (STRUCTURAL)
Rev No 9 Status F Date 2003-04-23 Cont ID  
Sent By shernand Date 2003-04-30 Time 14:21 Rev Time 1.00
Received By sthyng Date 2003-04-23 Time 16:06 Sent To  
Notes
2003-04-23 00:00:00**********CORRECTIONS************
  
 PLANS SUBMITTED FOR RESTAMP DO NOT MATCH
 PERMIT SET.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 SAMANTHA THYNG, BUILDING PLANS EXAMINER
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 8 Status P Date 2003-03-25 Cont ID  
Sent By shernand Date 2003-04-18 Time 13:52 Rev Time 0.80
Received By jwitmer Date 2003-03-25 Time 11:43 Sent To  
Notes
2003-03-25 00:00:00REVISION: 3/7/03 WAREHOUSE/ OFFICE
 INTERIOR WALL DELETION UNIT # 4.

Review Stop B BUILDING (STRUCTURAL)
Rev No 7 Status P Date 2003-02-12 Cont ID  
Sent By btrobaug Date 2003-03-18 Time 10:20 Rev Time 0.25
Received By jwitmer Date 2003-02-12 Time 13:33 Sent To  
Notes
2003-02-12 00:00:00SHOWER: ENTRY TO ROOM MEETS T-SHAPED
 ENTRY FOR 180 DEGREE TURNS.JW

Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status F Date 2003-02-12 Cont ID  
Sent By jwitmer Date 2003-02-12 Time 13:15 Rev Time 0.25
Received By jwitmer Date 2003-02-12 Time 13:15 Sent To  
Notes
2003-02-12 00:00:00BUILDING PLAN REVIEW
 PERMIT:02021928
 ADD: 5915 GEORGIA AVE
 CONT: LCI
 TEL: (561)307-4943 (JASON)
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 REVISION: DENIED
  
 1)11-4.2.3 SHALL PROVIDE AN ACCESSIBLE
 BATHROOM/ RESTROOM PER 11-4.23.3
 J WITMER
 BUILDING PLAN REVIEW

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status F Date 2003-01-23 Cont ID  
Sent By jwitmer Date 2003-01-23 Time 14:35 Rev Time 0.75
Received By jwitmer Date 2003-01-23 Time 14:35 Sent To  
Notes
2003-01-23 00:00:00REVISION DATED 12-10-02
  
 PERMIT:02021928
 ADDRESS: 5915 GEORGIA AVE
 CONT: LCI
 CELL: (561)307-4934DAVID
  
 REVISION: DENIED
 BUILDING REVIEW
  
 1)11-4.13.6 MANEUVERING CLEARENCES
 AT DOORS. MINIMUM MANEUVERING CLEARENCES
 AT DOORS THAT ARE NOT AUTOMATIC OR
 POWER-ASSISTED SHALL BE AS SHOWN IN
 FIG. 25. THE FLOOR OR GROUND AREA WITH
 IN THE REQUIRED CLEARENCES SHALL BE
 CLEAR & LEVEL.
  
 2)11-4.22.2 DOORS. ALL DOORS TO
 ACCESSIBLE TOLIET ROOMS SHALL COMPLY
 WITH 11-4.13. DOORS SHALL NOT SWING INTO
 CLEAR FLOOR SPACE REQUIRED FOR ANY
 FIXTURE.
  
 3) 11-4.21 SHOWER STALLS
 SIZE, CLEARENCES, SEAT, GRAB BAR
  
 4) 11-4.26.3 STRUCTURAL STRENGH BACKING
 REQUIREMENTS
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A
 DESCRIPTION OF THE REVISION MADE, IDEN-
 TIFYING THE SHEET OR SPECIFICATION PAGE
 WHERE THE CHANGES CAN BE FOUND, WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU
 FOR YOUR ANTICIPATED COOPERATION.
 JIM WITMER
 PLAN REVIEW
 TEL: (561)659-8096 EX.8412
 FAX: (561)659-8026

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2002-09-18 Cont ID  
Sent By hpiskura Date 2002-09-18 Time 15:33 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
2002-09-18 00:00:00ARCHITECT'S REVISION DATED 9/9/02

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2002-08-07 Cont ID  
Sent By jwitmer Date 2002-08-07 Time 15:52 Rev Time 1.25
Received By jwitmer Date 2002-08-07 Time 15:52 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2002-03-30 Cont ID  
Sent By jwitmer Date 2002-03-30 Time 11:23 Rev Time 0.00
Received By jwitmer Date 2002-03-30 Time 15:28 Sent To  
Notes
2002-03-30 00:00:00BUILDING PLAN REVIEW
 PERMIT # 02021928
 5715 GEORGIA AV
 CONT : LCI CONT
 TEL: 659-5111
  
 SBC= 1997 STANDARD BUILDING CODE
  
 1) A CURRENT SURVEY NOT PART OF THE
 PERMIT PACKET
 2) CONTRACTOR HAS NOT PROVIDED THE
 PRODUCT TESTING REPORTS FOR ALL GLAZED
 OPENINGS, EXT DOORS ROLL UP DOORS,
 ROOFING MATERIALS AS WELL AS HURRICANE
 PROTECTION FOR ALL GLAZED OPENINGS.
 3) IMPACT FEES: CONTRACTOR TO HAVE
 PLANS SUBMITTED TO COUNTY FOR IMPACT FEE
 ASSESSMENT.
 BUILDING PLAN REVIEW
 JIM WITMER
 (561)659-8096 X 8412

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-03-04 Cont ID  
Sent By hpiskura Date 2002-03-04 Time 16:27 Rev Time 0.00
Received By jwitmer Date 2002-03-04 Time 15:27 Sent To  
Notes
2002-03-04 00:00:00SHOW THE FIRE DESIGN NUMBER FOR THE FIRE
 RATED TENANT SEPARATION WALLS.SEE
 SBC 701.5
  
 PLEASE PROVIDE A RECENT PROPERTY SURVEY.
  
 SHOW THE FINISH FLOOR ELEVATIONS AND
 THAT OF THE SURROUNDING SITE SO THAT HC
 ACCESSIBILITY MAY BE DETERMINED.
  
 PROVIDE A SKETCH OF THE BUILDING
 DEPICTING THE PRESSURE ZONES FOR THE
 COMPONENTS AND CLADDING, INCLUDING THE
 ROOF COVERING.SEE SBC 1606.
  
 PROVIDE THE TEST REPORTS AND/OR THE
 NOTICE OF ACCEPTANCE FOR THE THE DOORS,
 WINDOWS AND ROOF COVERING.
  
 SHOW HOW THE GLAZED AREAS OF THE
 BUILDING EXTERIOR WILL COMPLY WITH THE
 CITY'S HURRICANE MISSILE IMPACT
 RESISTANT REQUIRMENTS. INCLUDE THE
 REQUISITE TEST REPORTS.
  
 BEFORE A PERMIT TO CONSTRUCT MAY BE
 ISSUED, IMPACT FEES MUST BE PAID TO THE
 COUNTY FOR THE CITY, THE PERMIT PLANS
 STAMPED BY THAT OFFICE, AND A COPY OF
 THE RECEIPT ATTACHED TO THE PERMIT
 APPLICATION.

Review Stop E ELECTRICAL
Rev No 7 Status F Date 2003-03-18 Cont ID  
Sent By btrobaug Date 2003-03-18 Time 10:20 Rev Time 1.00
Received By btrobaug Date 2003-03-18 Time 10:01 Sent To B
Notes
2003-03-18 00:00:00UNSAT
 ~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 PLEASE NOTE THAT THERE HAVE BEEN NEW
 LOADS ADDED TO THE UNITS ON PREVIOUS
 REVISIONS WITHOUT UPDATED
 CALCULATIONS.WATER HEATERS,EQUIPMENT
 CIRCUITS AND A 30 AMP "COOLER" CIRCUIT
 WERE ADDED.
  
 PLEASE REVISE CALCULATIONS SHOWING
 ACTUAL LOADS AFTER AND PRIOR TO DEMAND
 FACTORS.REVISE THE SERVICE TO SHOW SAME.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/659-8096 EXT.8392

Review Stop E ELECTRICAL
Rev No 6 Status P Date 2003-01-02 Cont ID  
Sent By sthyng Date 2003-03-14 Time 10:09 Rev Time 0.25
Received By dpalmer Date 2003-01-02 Time 12:46 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2002-12-27 Cont ID  
Sent By dpalmer Date 2002-12-27 Time 11:41 Rev Time 0.25
Received By dpalmer Date 2002-12-27 Time 11:41 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2002-09-20 Cont ID  
Sent By dpalmer Date 2002-09-20 Time 10:44 Rev Time 0.25
Received By dpalmer Date 2002-09-20 Time 10:44 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2002-09-16 Cont ID  
Sent By dpalmer Date 2002-09-16 Time 07:14 Rev Time 0.50
Received By dpalmer Date 2002-09-16 Time 07:14 Sent To  
Notes
2002-09-16 00:00:00****************** UNSAT ***************
  
 1)NOTE: PLEASE NOTE, ORIGINAL NOTES
 REQUESTED ALL DEVICES TO HAVE CIRCUITING
 SHOWN ON PLANS AND CORRELATE W/ PANEL
 SCHEDULE SUBMITTED . (CAN BE TYPICAL).
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW.
 561-659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-04-01 Cont ID  
Sent By dpalmer Date 2002-04-01 Time 09:44 Rev Time 0.00
Received By dpalmer Date 2002-04-01 Time 09:44 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2002-03-05 Cont ID  
Sent By dpalmer Date 2002-03-05 Time 15:52 Rev Time 0.00
Received By dpalmer Date 2002-03-05 Time 15:52 Sent To  
Notes
2002-03-05 00:00:00***************** UNSAT *************
  
 1)NOTE: PLEASE SUBMIT AIC RATINGS FOR
 ALL NEW EQUIPMENT BEING INSTALLED.
 MAINS/PANELS/BREAKERS MUST BE RATED FOR
 THE AVAILABLE FAULT CURRENT PER 110-9.
  
 2)NOTE: PLEASE PROVIDE CIRCUITING ON
 PLANS AND CORRELATE WITH SUBMITTED
 PANEL SCHEDULES.
  
 3)NOTE: PLEASE CLARIFY CIRCUIT PER
 600-5.
  
 PLEASE SUBMIT THE ABOVE INFORMAITON FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop ENG ENGINEERING CSD
Rev No 3 Status   Date   Cont ID  
Sent By lsmith Date 2003-01-17 Time 11:59 Rev Time 0.00
Received By lsmith Date   Time   Sent To  
Notes
2003-01-17 00:00:00PER NAM 1/16/03 LS

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2002-07-24 Cont ID  
Sent By mamini Date 2002-07-24 Time 11:15 Rev Time 3.00
Received By mamini Date 2002-07-24 Time 11:15 Sent To  
Notes
2002-07-24 00:00:00PASSED :
 1. RESPONSES TO THE REVIEW COMMENTS
 DATED 3-6-02 SATISFACTORY.
 IF ANY QUESTIONS PLEASE CONTACT 659-8096
 EXT. 8492 MOHAMMAD R. AMINI

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2002-03-06 Cont ID  
Sent By mamini Date 2002-03-06 Time 11:07 Rev Time 2.00
Received By mamini Date 2002-03-06 Time 11:07 Sent To  
Notes
2002-03-06 00:00:00FAILED :
 1. PLEASE SHOW LOCATIONS FOR METER AND
 BACKFLOW PREVENTERS.
 2. PLEASE SHOW THE INVERT ELEVATION FOR
 EXISTING SERVICE LATERAL AND/OR CLEAN-
 OUT FROM MAIN.
 3. IT SHALL BE THE RESPONSIBILITY OF THE
 DEVELOPER/ENGINEER/CONTRACTOR TO DESIGN
 AND INSTALL THE NEW INVERT ELEVATION FOR
 THE BUILDING LATERAL TO MATCH OR BE
 HIGHER THAN THE EXISTING WHILE MAINTAIN-
 ING THE PLUMBING CODE REQUIREMENT FOR
 EFFLUENT PIPE FALL WITH MINIMUM OF THREE
 FEET COVER. IF THESE REQUIREMENTS CAN
 NOT BE MET, THE CITY MUST BE NOTIFIED
 PRIOR TO INSTALLATION.659-8040, 659-8079
 4. CIVIL PLANS MUST BE REVIEWED AND
 APPROVED BY PUBLIC UTILITIES ENGINEERING
 SERVICES 659-8040 EXT. 2306 M. GONZALEZ.
 4. CITY'S STANDARD MAY BE OBTAINED FROM
 PUBLIC UTILITIES ENGINEERING SERVICES,
 659-8040, EXT.2306 M. GONZALEZ
 5. DUMPSTER ENCLOSURE MUST BE PER CITY'S
 REQUIREMENT IF GARBAGE TO BE PICKED UP
 BY THE CITY, SEE ATTACHED.
 6. WATER QUALITY INLET IN DUMPSTER
 ENCLOSURE AREA IS NOT RECOMMENDED.
 7. DRIVEWAY APPROACHES MUST AT MIN. BE
 PER CITY'S STANDARD, SEE ATTACHED.
 8. CRUSHED CONCRETE FOR THE BASE
 CONSTRUCTION WOULD NOT BE ACCEPTABLE.
 9. POLLUTION PREVENTION PLANS MUST BE
 INSTALLED IN FIELD PRIOR TO ANY EARTH
 WORKS. NOTE TO THE G.C MUST BE ADDED.
 IF ANY QUESTIONS PLEASE CONTACT 659-8096
 EXT. 8492 MOHAMMAD R. AMINI

Review Stop FIRE FIRE DEPARTMENT
Rev No 6 Status P Date 2003-01-17 Cont ID  
Sent By lsmith Date 2003-01-17 Time 12:00 Rev Time 0.25
Received By lsmith Date   Time   Sent To  
Notes
2003-01-17 00:00:00PER NOM 1/16/03 LS

Review Stop FIRE FIRE DEPARTMENT
Rev No 5 Status P Date 2003-01-16 Cont ID  
Sent By nmccray Date 2003-01-16 Time 13:54 Rev Time 0.00
Received By nmccray Date 2003-01-16 Time 13:54 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status P Date 2002-09-13 Cont ID  
Sent By mcarsill Date 2002-09-13 Time 16:48 Rev Time 0.00
Received By mcarsill Date 2002-09-13 Time 16:48 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2002-04-02 Cont ID  
Sent By mcarsill Date 2002-04-02 Time 17:23 Rev Time 0.00
Received By mcarsill Date 2002-04-02 Time 17:23 Sent To  
Notes
2002-04-02 00:00:00RECEIVED LETTER FROM ROBERT BELL,
 ARCHITECT, DELETING THE SEPARATION
 WALLS BETWEEN THE OFFICE AND STORAGE
 AREAS OF EACH TENANT SPACE. LETTER
 INDICATES THAT THESE ITEMS WILL
 BE ADDRESSED LATER IN THE TENANT
 BUILD-OUTS.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 659-8096,EXT. 8497
 835-2910

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2002-03-21 Cont ID  
Sent By mcarsill Date 2002-03-21 Time 14:54 Rev Time 0.00
Received By mcarsill Date 2002-03-21 Time 14:54 Sent To  
Notes
2002-03-21 00:00:00A) THE INTERIOR WALLS THAT SEPARATE
 THE OFFICE AREAS FROM THE WAREHOUSE
 AREAS ARE TO BE AT LEAST ONE FIRE
 PROTECTED WITH AT LEAST 45 MINUTE
 FIRE DOORS. THE PLANS DO NOT REFLECT
 THIS.
 B) BUILDING ADDRESS REQUIRED ON
 BUILDING.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 659-8096,EXT.8497
 835-2910

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2002-03-01 Cont ID  
Sent By mcarsill Date 2002-03-01 Time 11:03 Rev Time 0.00
Received By mcarsill Date 2002-03-01 Time 11:03 Sent To  
Notes
2002-03-01 00:00:00A) PLEASE BE ADVISED THAT THE PROPOSED
 BUILDING IS LOCATED WITHIN THE CITY
 FIRE LIMITS. CERTAIN RESTRICTIONS WILL
 APPLY TO THE CONSTRUCTION OF THIS
 BUILDING. PLEASE SEE APPENDIX F OF THE
 STANDARD BUILDING CODE.
 B) BUILDING ADDRESS REQUIRED ON
 BUILDING.
 C) TENANT SEPARATION WALLS SHOULD BE
 IDENTIFIED AS 5/8 TYPE X DRYWALL.
 D) THE WAREHOUSE AREAS ARE TO BE
 SEPARATED FROM THE OFFICE AREAS BY AT
 LEAST ONE HOUR FIRE RATINGS WITH
 OPENING PROTECTIVES RATED FOR THAT
 APPLICATION. IT APPEARS NO FIRE
 SPRINKLERS ARE PLANNED.
 E) PLEASE PROVIDE INTERIOR FINISH
 CLASSIFICATION INFORMATION FOR WALLS
 AND CEILINGS.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 659-8096,EXT.8497
 835-2910

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2003-05-01 Cont ID  
Sent By shernand Date 2003-04-30 Time 14:21 Rev Time 0.00
Received By shernand Date 2003-04-30 Time 14:21 Sent To P
Notes
2003-05-01 00:00:00PAUL SHANTZ DESK

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2003-04-18 Cont ID  
Sent By shernand Date 2003-04-18 Time 13:52 Rev Time 0.00
Received By shernand Date 2003-04-18 Time 13:52 Sent To B
Notes
2003-04-18 00:00:00JW DESK TO RESTAMP.

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-03-14 Cont ID  
Sent By sthyng Date 2003-03-14 Time 10:07 Rev Time 0.00
Received By sthyng Date 2003-03-14 Time 10:07 Sent To E
Notes
2003-03-14 00:00:00TO BT DESK - HE WILL SEND TO JW

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-02-06 Cont ID  
Sent By btrobaug Date 2003-02-06 Time 12:03 Rev Time 0.00
Received By btrobaug Date 2003-02-06 Time 12:03 Sent To P
Notes
2003-02-06 00:00:00"P" IN BOX./WRT.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-01-02 Cont ID  
Sent By dpalmer Date 2003-01-02 Time 12:46 Rev Time 0.00
Received By dpalmer Date 2003-01-02 Time 12:46 Sent To  
Notes
2003-01-02 00:00:00TO COMM BOARD #52

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2002-12-27 Cont ID  
Sent By dpalmer Date 2002-12-27 Time 11:42 Rev Time 0.00
Received By dpalmer Date 2002-12-27 Time 11:42 Sent To  
Notes
2002-12-27 00:00:00TO COMM BOARD #6

Review Stop M MECHANICAL (A/C)
Rev No 4 Status N Date 2003-04-30 Cont ID  
Sent By pkrauss Date 2003-04-30 Time 12:41 Rev Time 0.40
Received By pkrauss Date 2003-04-30 Time 12:39 Sent To  
Notes
2003-04-30 00:00:00NO MECHANICAL PLANS SUBMITTED FOR REVIEW
  
 PLAN SHEET 1 (PLAN/RISER/SCHED),
 INDICATES A AHU WITH CU ON THE ROOF.
 PLEASE PROVIDE THE FOLLOWING INFORMATION
 FOR REVIEW WITH MECHANICAL PERMIT
 APPLICATION.
  
 1.OUTSIDE AIR CALCS AS PER 2001 FBC(M)
 TABLE 403.3.
  
 2.EXHAUST FANS FOR RESTROOMS, (MAKE,
 MODEL, CFMS).INDICATE LOCATION OF
 EXHAUST FANS.
  
 3.PROVIDE DUCT LAYOUT.
  
 4.SHOW COMPLIANCE WITH 2001 FBC
 1511.7 ON THE HEIGHT FOR THE CONDENSER
 UNIT STANDS ON THE ROOF.PLEASE
 PROVIDE DETAIL.
  
 5.EQUIPMENT LOCATED ON THE ROOF AT A
 HEIGHT EXCEEDING 16 FT SHALL HAVE A
 PERMANENT MEANS OF ACCESS. 2001 FBC(M)
 306.5.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status N Date 2003-01-21 Cont ID  
Sent By kstevens Date 2003-04-26 Time 07:43 Rev Time 0.25
Received By pkrauss Date 2003-01-21 Time 13:54 Sent To  
Notes
2003-01-21 00:00:00MECHANICAL PERMIT REQUIRED - NO PLANS
 SUBMITTED.REVISION SUBMITTED 12-23-02
 INDICATES AC & COOLER ON ELECTRICAL
 PANEL SCHEDULE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561)659-8096
 EXT. 8388.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2002-04-04 Cont ID  
Sent By pkrauss Date 2002-04-04 Time 10:48 Rev Time 0.35
Received By pkrauss Date 2002-04-04 Time 10:47 Sent To  
Notes
2002-04-04 00:00:00AS PER LETTER DATED MARCH 8, 2002 -
 LETTER FROM ROBERT L. BELL ARCHITECT PA.
 RESPONSE TO COMMENTS OF NO MECH PLANS
 SUBMITTED....MECH PLANS &
 SPECIFICATIONS TO BE SUBMITTED BY EACH
 TENANT SPACE.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2002-03-04 Cont ID  
Sent By pkrauss Date 2002-03-04 Time 12:37 Rev Time 0.35
Received By pkrauss Date 2002-03-04 Time 12:33 Sent To  
Notes
2002-03-04 00:00:00 
 PLANS DO NOT INDICATE WHAT CODE BUILDING
 WAS DESIGNED UNDER.PLEASE SPECIFY
 EITHER THE 1997 STANDARD BUILDING CODE
 OR 2001 FLORIDA BUILDING CODE.
  
 NO MECHANICAL PLANS SUBMITTED FOR
 REVIEW.PLEASE PROVIDE PLANS WITH
 MECHANICAL PERMIT APPLICATION.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop P PLUMBING
Rev No 9 Status F Date 2003-04-26 Cont ID  
Sent By shernand Date 2003-05-01 Time 09:56 Rev Time 0.25
Received By kstevens Date 2003-04-26 Time 07:37 Sent To M
Notes
2003-04-26 00:00:00RESTAMP DENIED
  
 1) SET FOR RESTAMP DOES NOT REFLECT THE
 FILE COPY SET.
 2) THERE ARE REVISIONS TO THE ORIGINAL
 SET ON THE SET SUBMITTED.
 3) IF A RESTAMP SET IS NEEDED, PLEASE
 SUBMIT A SET THAT REFLECTS WHAT WAS
 ISSUED.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377
 (561) 805-6721
 FAX (561) 653-2692

Review Stop P PLUMBING
Rev No 8 Status P Date 2003-02-12 Cont ID  
Sent By pkrauss Date 2003-02-12 Time 09:53 Rev Time 0.35
Received By pkrauss Date 2003-02-12 Time 09:53 Sent To  
Notes
2003-02-12 00:00:00APPROVED PER PAUL SCHMITZ

Review Stop P PLUMBING
Rev No 7 Status F Date 2003-02-07 Cont ID  
Sent By kstevens Date 2003-02-07 Time 11:03 Rev Time 0.33
Received By kstevens Date 2003-02-07 Time 11:03 Sent To  
Notes
2003-02-07 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 11
  
 1) IF SHOWER WILL BE ADDED IN THE FUTURE
 THE ROOM SHALL COMPLY AND BE LARGE
 ENOUGH FOR A 5' TURNING SPACE.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop P PLUMBING
Rev No 6 Status F Date 2003-02-04 Cont ID  
Sent By btrobaug Date 2003-02-06 Time 12:04 Rev Time 0.60
Received By kstevens Date 2003-02-04 Time 09:00 Sent To  
Notes
2003-02-04 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 11
  
 1) PER SECTION 11-4.1.3(11) ADAPTABLE
 SHOWERS SHALL COMPLY WITH 11-4.23.
 CONTROLS SHALL BE LOCATED PER 11-4.21.5,
 & AN UNOBSTRUCTED TURNING SPACE COMPLY-
 ING WITH 11-4.2.3 SHALL BE PROVIDED WITH
 IN AN ACCESSIBLE BATHROOM/SHOWER ROOM,
 PER 11-4.23.3. PLEASE PROVIDE DETAILS
 FOR ALL SECTIONS TO SHOW ADAPTABILITY.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop P PLUMBING
Rev No 5 Status P Date 2003-01-21 Cont ID  
Sent By kstevens Date 2003-01-21 Time 14:25 Rev Time 1.50
Received By kstevens Date 2003-01-21 Time 14:25 Sent To  
Notes
2003-01-21 00:00:00REVISION OK - ADD WATER HEATER

Review Stop P PLUMBING
Rev No 4 Status F Date 2003-01-21 Cont ID  
Sent By kstevens Date 2003-01-21 Time 13:12 Rev Time 1.25
Received By kstevens Date 2003-01-18 Time 16:10 Sent To  
Notes
2003-01-21 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 11
  
 1) SHT 1 SHOWER STALL, SHOWER SHALL
 COMPLY WITH 11-4.21 AND ALL SUBSECTIONS.
 ALSO THE CLEAR FLOOR SPACE, TURNING
 RADIUS, ACCESSIBLE DOOR ECT.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop P PLUMBING
Rev No 3 Status P Date 2002-08-06 Cont ID  
Sent By kstevens Date 2002-08-02 Time 18:18 Rev Time 0.00
Received By kstevens Date 2002-08-02 Time 18:18 Sent To  
Notes
2002-08-02 00:00:00DENIED
 REFERENCE: SPC-94-FACBC-97
  
 1) PER SPC-94 TABLE 407 DRINKING FOUNT-
 AINS ARE REQUIRED FOR EACH SPACE. RES-
 PONSE NOTED. THIS IS NOT CONSIDERED A
 FIXTURE. EACH DRINKING FOUNTAIN SHALL BE
 PIPED INTO THE SANITARY AND SHALL BE
 SUPPLIED WITH POTABLE WATER FROM THE
 WATER RISER TO BE CONSIDERED A FIXTURE.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop P PLUMBING
Rev No 2 Status F Date 2002-04-20 Cont ID  
Sent By kstevens Date 2002-04-19 Time 20:58 Rev Time 0.00
Received By kstevens Date 2002-04-19 Time 20:58 Sent To  
Notes
2002-04-20 00:00:00DENIED
 REFERENCE: SPC-94-FACBC-97
  
 1) PER SPC TABLE 407 DRINKING FOUNTAINS
 ARE REQUIRED. THERE IS NO EXCEPTION FOR
 SIZE OF SPACE.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-03-04 Cont ID  
Sent By kstevens Date 2002-03-04 Time 18:34 Rev Time 0.75
Received By kstevens Date 2002-03-04 Time 18:34 Sent To  
Notes
2002-03-04 00:00:00DENIED
 REFERENCE: FACBC-97 - BUILDING CODE ??
  
 1) PLANS DO NOT SPECIFY WHICH CODE THIS
 BLDG IS DESIGNED UNDER. PLEASE INDICATE
 EITHER SPC OR FLA. BLDG CODE FOR REVIEW.
 2) SHT #1 PLEASE PROVIDE MINIMUM FACIL-
 ITIES. DRINKING FOUNTAIN - SERVICE SINK
 ECT MIGHT BE REQUIRED PER CODE.
 3) SHTS #'S 2 & 3PLEASE CALCULATE PRI-
 MARY AND SECONDARY ROOF DRAINS PER CODE.
 CONSIDER 1/2 AREA OF VERTICAL WALLS FOR
 EACH CALCULATIONS AND SHOW LOCATIONS OF
 PRIMARY AND SECONDARY DRAIN ON PLANS.
 SUBMIT STORM RISER DIAGRAMS AND INDICATE
 DOWNSPOUT/LEADER SIZE.
 4) SHT 1 WATER RISER DIAGRAM REQUIRED.
 SHOW PIPE SIZES, AND IF WATER HAMMER
 ARRESTORS ARE SHOWN LOCATION SHALL BE
 NEAR FIXTURE IN AN "EFFECTIVE RANGE" NOT
 AT TOP OF DROP.
 5) BACKFLOW REQUIRED ON WATER SERVICE.
 LOCATION TO BE APPROVED BEFORE INSTALL-
 ATION. CALL 659-8005
 6) PLUMBING CONTRACTOR TO SUPPLY VALVE,
 BACKFLOW (WATTS N36), AND ADAPTOR FOR
 IRRIGATION CONTRACTOR.
 7) SEPARATE PERMIT REQUIRED FOR IRRIGAT-
 ION. SUBMIT PLANS WITH PERMIT APPLICAT-
 ION.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop Z ZONING
Rev No 1 Status P Date 2002-02-28 Cont ID  
Sent By sgraham Date 2002-02-28 Time 11:56 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***