Plan Review Details - Permit 02021861
Plan Review Stops For Permit 02021861
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2002-05-06 Cont ID  
Sent By btrobaug Date 2002-10-03 Time 16:52 Rev Time 2.00
Received By rmcdouga Date   Time   Sent To  
Notes
2002-05-06 00:00:00************BUILDING PROVISO************
  
 1) PROVIDE (2) CURRENT AND COMPLETE
 COPIES OF SBCCI OR METRO-DADE PRODUCT
 APPROVALS FOR OVERHEAD GARAGE DOOR AND
 FRENCH DOORS AS INDICATED ON PLANS,
 PRIOR TO INSTALLING THEM.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-04-04 Cont ID  
Sent By kstevens Date 2002-03-13 Time 10:10 Rev Time 4.00
Received By rmcdouga Date   Time   Sent To  
Notes
2002-04-04 00:00:00*************BUILDING UNSAT*************
  
 1) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 3)THE OWNER/AGENTS SIGNATURE IS REQUIRED
 ON THE FL ENERGY EFFICIENCY CODE FORM.
 PROVIDE TWO (2) COPIES.
  
 4) PROVIDE (2) COPIES OF SURVEY.
  
 5) INDICATE ON PLANS THAT EXISTING
 BEDROOM ADJACENT TO ADDITION HAS AN
 EXISTING WINDOW THAT COMPLIES WITH 97SBC
 SECTION 1005.4 FOR EMERGENCY EGRESS OR A
 NEW ONE THAT COMPLIES WILL BE INSTALLED.
 INDICATE WINDOW SIZE AND TYPE FOR THIS
 WINDOW ON PLAN.
  
 6) THE GLASS BLOCK IN THE BATHROOM MUST
 COMPLY WITH 97SBC SECTIONS 2405.2.1 AND
 2405.2.2(5) FOR GLAZING IN HAZARDOUS
 LOCATIONS. GLASS BLOCKS MUST HAVE A
 UNIFORM FACE THICKNESS OF 0.25".
  
 7) ADD CARPORT TO GARAGE CONVERSION TO
 THE DESCRIPTION OF WORK ON THE PERMIT
 APPLICATION.
  
 8) INDICATE ON PLANS THE SIZE OF THE
 ATTIC ACCESS. MINIMUM OPENING IS 22"X36"
 PER SEC. 2309.6.
  
 9) SECTION FFC ON SHEET 2 OF PLANS DOES
 NOT INDICATE THE SIZE OF THE DOWELS. THE
 SECTION INDICATED ON THE FLOOR PLAN IS
 LABELED FCC AND THE ACTUAL SECTION IS
 LABELED FFC. PLEASE CORRECT.
  
 10) THE ROOF FRAMING PLAN ON SHEET 2
 DOES NOT SPECIFY WHICH DETAIL TO REFER
 TO WHERE NEW TRUSSES BEAR ON EXISTING
 BEAM. PLEASE SPECIFY THE ANCHORS AND
 FASTENERS.
  
 11) INCORRECT INFORMATION IS GIVEN FOR
 EMERGENCY EGRESS WINDOWS ON SHEET 1.
 PLEASE CORRECT. SEE NOTES ON PLAN.
  
 12) ADEQUATE FOUNDATION IS REQUIRED AT
 CARPORT TO SUPPORT NEW BLOCK WALLS.
 INDICATE ON PLANS THE THICKNESS OF THE
 EXISTING SLAB AND/OR HOW IT WILL BE
 MADE ADEQUATE.
  
 13)INDICATE THE ROOF PITCH ON THE PLANS.
  
 14) INDICATE THE ELEVATION DIMENSIONS,
 INCLUDING BEAM HEIGHTS, CEILING HEIGHT,
 ETC. ON THE PLANS.
  
 15)PROVIDE (2) PRODUCT APPROVALS, KEY
 PLANS AND INSTALLATION SCHEDULES
 INDICATING THE SPECIFIC TYPES OF ANCHORS
 TO BE USED FOR STORM PANELS. OR APPLY
 UNDER A SEPARATE PERMIT AT A LATER DATE.
  
 16) PROVIDE (2) CURRENT AND COMPLETE
 COPIES OF SBCCI OR METRO-DADE PRODUCT
 APPROVALS FOR:
 - GLASS BLOCK
 - ALL EXTERIOR DOORS (EACH TYPE)
 - ALL WINDOWS (EACH TYPE)
 - GARAGE DOOR
 - ROOF COVERING
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2002-11-04 Cont ID  
Sent By btrobaug Date 2002-11-04 Time 12:41 Rev Time 0.25
Received By btrobaug Date 2002-11-04 Time 12:35 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-10-03 Cont ID  
Sent By btrobaug Date 2002-10-03 Time 16:51 Rev Time 0.00
Received By btrobaug Date 2002-10-03 Time 16:51 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-03-06 Cont ID  
Sent By btrobaug Date 2002-03-06 Time 10:08 Rev Time 0.00
Received By btrobaug Date 2002-03-06 Time 09:26 Sent To M
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2002-03-06 Cont ID  
Sent By btrobaug Date 2002-03-06 Time 10:08 Rev Time 0.25
Received By pkrauss Date 2002-03-06 Time 10:17 Sent To P
Notes
2002-03-06 00:00:00 
 NO MECHANICAL PLANS SUBMITTED FOR
 REVIEW.PLEASE PROVIDE PLANS WITH
 MECHANICAL PERMIT APPLICATION.
  
 PLEASE NOTE, BATHROOM SHALL HAVE A
 WINDOW WITH A MINIMUM OF 3 SQ FT OF
 OPEN SPACE OR AIR SHALL BE MECHANICALLY
 EXHAUSTED.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.
  
 MECHANICAL PERMIT 00120524
  
 PLEASE PROVIDE MANUFACTURER SUBMITTAL
 DATA FOR DRYERS BEING INSTALLED IN
 UNITS THAT THE IN-LINE FAN HAS BEEN
 DELETED. EXHAUST DUCT EXCEEDS 25FT
 MAXIMUM AS PER 1997 SMC 509.3.
  
 REVISIONS APPROVED WITH THE EXCEPTION
 OF"PROPOSED KITCHEN HOOD".TERMINATION
 FOR GREASE DUCT SHALL COMPLY WITH NFPA
 96 AND 1997 SMC CHAPTER 5.PLEASE NOTE
 AS PER 1997 SMC 506.1, TERMINATION OF
 EXHAUST SHALL BE LOCATED 10 FT FROM ANY
 ADJACENT BUILDING, PARKING AREA,
 ADJACENT PROPERTY LINE, WINDOW, DOOR OR
 AIR INTAKE.ADDITIONAL PLANS & PERMITS
 REQUIRED FOR HOOD (GREASE DUCT & MAKEUP
 AIR), FIRE SUPRESSION, AND WALK-IN
 COOLERS/FREEZERS.PROVIDE MANUFACTURER
 SUBMITTAL DATA WITH PLANS & PERMIT
 APPLICATION.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-03-13 Cont ID  
Sent By pkrauss Date 2002-03-06 Time 10:24 Rev Time 0.50
Received By kstevens Date 2002-03-13 Time 10:10 Sent To B
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2002-11-04 Cont ID  
Sent By rmcdouga Date 2002-11-04 Time 09:46 Rev Time 1.00
Received By rmcdouga Date   Time   Sent To  
Notes
2002-11-04 00:00:00REVISION TO ADD COVERED PORCH IS O.K.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2002-10-03 Cont ID  
Sent By rmcdouga Date 2002-10-03 Time 13:42 Rev Time 1.00
Received By rmcdouga Date   Time   Sent To  
Notes
2002-10-03 00:00:00REVISION DENIED
  
 1) PROVIDE (2) COPIES OF SURVEY WITH THE
 DIMENSIONS OF THE FRONT ENTRY ADDITION
 INDICATED. (ZONING REVIEW IS REQUIRED)
  
 2) THE TRUSS ANCHOR SCHEDULE DOES NOT
 INDICATE THE SIZE OR NUMBER OF NAILS
 REQUIRED FOR THE ATTACHMENT TO THE BEAM,
 FOR ANCHOR A2 (TAPL 16).
  
 3) INDICATE THE MATERIAL THAT WILL BE
 INSTALL ON THE ENTRY CEILING.
  
 4) INDICATE ATTIC VENTS AS REQUIRED BY
 FBC 2309.7.
  
 5)PROVIDE (2) CURRENT AND COMPLETE
 COPIES OF SBCCI OR METRO-DADE PRODUCT
 APPROVALS FOR ROOFING MATERIAL.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202

Review Stop Z ZONING
Rev No 1 Status P Date 2002-02-28 Cont ID  
Sent By sgraham Date 2002-02-28 Time 09:51 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***