Plan Review Details - Permit 02021137
Plan Review Stops For Permit 02021137
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2002-03-06 Cont ID  
Sent By btrobaug Date 2002-03-04 Time 17:52 Rev Time 0.75
Received By lsmith Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-03-04 Cont ID  
Sent By btrobaug Date 2002-03-04 Time 17:52 Rev Time 0.00
Received By btrobaug Date 2002-03-04 Time 17:35 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2002-05-17 Cont ID  
Sent By kstevens Date 2002-05-17 Time 13:49 Rev Time 0.00
Received By kstevens Date 2002-05-17 Time 13:49 Sent To  
Notes
2002-05-17 00:00:00PASSED/PROVISO
  
 HARTFORD LOOP SHALL BE EXTERNAL FOR
 HEATER
 `

Review Stop P PLUMBING
Rev No 2 Status F Date 2002-05-04 Cont ID  
Sent By kstevens Date 2002-05-04 Time 13:02 Rev Time 0.00
Received By kstevens Date 2002-05-04 Time 12:59 Sent To  
Notes
2002-05-04 00:00:00DENIED
 REFERENCE: FBC-2001 424.2 SWIMMING POOLS
  
 1) PLEASE ADJUST YOUR NOTES, DETAILS, OR
 SUBMITTALS TO REFLECT THE FOLLOWING IN-
 FORMATION REQUIRED FOR PLAN REVIEW
 2)
 FBC-2001 SEC 424.2.6.6.2 SHOW COMPLIANCE
 WITH ANSI/ASME A112.19.8M. PROVIDE MODEL
 NUMBER AND MANUF INFO FOR VAC LOCK.
 (GIVE DETAIL OR ADD NOTE)(SUBMITTAL)
 3)
 FBC-2001 SEC 424.2.14.2 WATER RETENTION,
 PROVIDE A POSITIVE MEANS OF RETAINING
 WATER IN THE HEATER WHEN PUMP IS SHUT
 OFF. (MANUFACTURE CUT SHEETS SUBMITTAL)
 PLEASE PROVIDE DETAIL NOT SHOWN ON CUT
 SHEET SUBMITTED.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-03-03 Cont ID  
Sent By pschmitz Date 2002-03-03 Time 11:24 Rev Time 1.50
Received By pschmitz Date   Time   Sent To  
Notes
2002-03-03 00:00:00PLUMBING PLAN REVIEW, FBC 2001,DENIED.
 (1)GENERAL NOTES #1,THE CURRENT CODE
 IS,FBC 2001 SEC 424.2.6. ENGINEERING
 DESIGN. NOT SBCCI 94 PBC SWIMMING POOL.
 (2) SWIMMING POOL DRAWING IS NOT ACCEPT-
 ABLE, COMPLY WITH FBC 2001 BUILDING,DRAW
 INGS AND SPECIFICATIONS,SEC 104.2
 SUFFICENT CLARITY AND DETAIL TO INDICATE
 THE NATURE AND CHARACTER OF WORK.
 (3) SEC 424.2.6.6. ENTRAPMENT PROTECTION
 FOR SUCTION INLETS, PROVIDE DETAIL, FOR
 MAIN DRAIN AND VACUM CLEANING FITTING.
 (4) SEC 424.2.7.2 PROVIDE DETAILS OF
 MOUNTING AND ANCHORING POOL EQUIPMENT.
 (5) SEC 424.2.9 WATER SUPPLY AND LOCAL
 ORDINANCE,32853-95 BACK FLOW PREVENTER
 REQUIRED ON WATER SERVICE.
 (6) ESC 424.2.13.2 JOINTS, CONNECTIONS.
 PURPLE PRIMER REQUIRED ON PVC PIPING,
 FBC 2001 PLUMBING, SEC 605.21
 (7) SEC 424.2.14.2 WATER RETENTION.
 PROVIDE A DETAIL OF A POSITIVE MEANS OF
 RETAINING WATER IN THE POOL HEATER WITH
 A BY-PASS.
 (8) SEC 424.2.145 GAS PIPING, SEPERATE
 PLANS AND PERMIT REQUIRED.
 END OF COMMENTSPAUL SCHMITZ
 QUESTIONS561-659-8096X8233

Review Stop Z ZONING
Rev No 1 Status P Date 2002-02-20 Cont ID  
Sent By sgraham Date 2002-02-20 Time 16:09 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***