Plan Review Details - Permit 02020826
Plan Review Stops For Permit 02020826
Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status P Date 2002-07-18 Cont ID  
Sent By rbrown Date 2002-07-18 Time 17:46 Rev Time 0.00
Received By rbrown Date 2002-07-18 Time 17:46 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2002-07-02 Cont ID  
Sent By rbrown Date 2002-07-02 Time 20:54 Rev Time 0.00
Received By rbrown Date 2002-07-02 Time 20:54 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2002-05-22 Cont ID  
Sent By rbrown Date 2002-05-22 Time 09:09 Rev Time 0.00
Received By rbrown Date 2002-05-22 Time 09:09 Sent To  
Notes
2002-05-22 00:00:00BUILDING PLAN REVIEW
 ******PROVISO*******
 ROBERT BROWN(561) 659 8096 EXT 8499
  
 SBC = STANDARD BUILDING CODE 1997
 SBC*= STANDARD BUILD'G CODE (CITY AMEND)
  
 --PROVISO--
 SBC* 104.1.1SHUTTERS FOR WINDOWS AND
 FRENCH DOORS.A SEPARATE PERMIT
 APPLICATION WILL BE REQUIRED FOR THE
 HURRICANE MISSILE IMPACT PROTECTION
 SHUTTERS.PRODUCT APPROVALS WILL BE
 REQUIRED.
  
 --PROVISO--
 SBC* 1606.4.2THE PRODUCT APPROVAL
 SUBMITTAL FORM FOR THE 'CUSTOM WINDOWS'
 DOES NOT MAKE REFERENCE TO WINDOWS W207
 AND W208.ACCORDING TO THE WINDOW
 SCHEDULE THESE TWO WINDOWS ARE "NEW
 WINDOW BY OWNER CERTIFIED BY ENGINEER".
 EITHER ADD REFERENCE TO W207 AND W208 ON
 THE SUBMITTAL FORM (IF APPROPRIATE) OR
 SUBMIT SEPARATE PRODUCT APPROVALS FOR
 THESE WINDOWS.
 NOTE: IS W208 REQUIRED, IT DOES NOT
 APPEAR ON THE PLANS/ELEVATIONS?

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2002-05-03 Cont ID  
Sent By rbrown Date 2002-05-03 Time 14:39 Rev Time 0.00
Received By rbrown Date 2002-05-03 Time 14:39 Sent To  
Notes
2002-05-03 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 659 8096 EXT 8499
  
 SBC = STANDARD BUILDING CODE 1997
 SBC*= STANDARD BUILD'G CODE (CITY AMEND)
 FBC = FLORIDA BUILDING CODE 2001
 FBC*= FLORIDA BUILD'G CODE (CITY AMEND)
  
 FOR CONSISTENCY, THE FOLLOWING COMMENTS
 ARE NUMBERED AS PER THE BUILDING PLAN
 REVIEWS OF 3/7/02 AND 4/15/02:
  
 3) FBC 424.2.17 BARRIER TO SWIMMING POOL
 THIS COMMENT HAS NOT BEEN PROPERLY
 ADDRESSED.THE PLANS DO NOT HAVE
 SUFFICIENT NOTES/DETAILS TO DEMONSTRATE
 COMPLIANCE WITH FBC 424.2.17.1 THRO' 14.
 NOTE THAT THE USE OF 'WHITE-OUT' ON
 PLANS FOR PERMITTING IS INAPPROPRIATE.
 SUBMIT PLANS THAT DEMONSTRATE COMPLIANCE
  
 7) SBC* 1606.4.2PRODUCT APPROVALS.
 THIS COMMENT HAS NOT BEEN ADDRESSED.
 SUBMIT PRODUCT APPROVAL NOTICE(S) OF
 ACCEPTANCE FOR THE NEW WINDOWS W101,
 W107, W108 AND W201, AND NEW DOORS D101,
 D103, D105, D108 AND D204.ALSO, NOTE
 THAT THE EAST ELEVATION IS STILL
 REFERING TO D205 WHICH SHOULD BE D204.
  
 8) SBC* 1606.4.2PRODUCT APPROVALS FOR
 'CUSTOM DOORS AND WINDOWS'. THIS COMMENT
 HAS NOT BEEN PROPERLY ADDRESSED.THE
 COPIES OF THE PRODUCT APPROVAL SUBMITTAL
 FORMS, THAT HAVE BEEN SIGNED BY THE
 ENGINEER OF RECORD, ARE NOW MISSING
 ANSWERS TO QUESTIONS 1.0(F) AND 9.1
  
 11) SBC* 2308EXTERIOR STUD WALL.THIS
 COMMENT HAS NOT BEEN PROPERLY ADDRESSED.
 DETAIL 8/A4.00 SHALL BE AMENDED (OR A
 DETAIL ADDED) TO SHOW THE ATTACHMENT OF
 THE NEW STUD WALL TO THE EXISTING WALL,
 THE WORST CASE BEING IF THE POINT OF
 ABUTTMENT DOES NOT COINCIDE WITH AN
 EXISTING STUD LOCATION.
  
  
 NOTE:
 CHAPTER 553.80(2)(B) FLORIDA STATUTES
 STATES THAT A LOCAL GOVERNMENT SHALL
 IMPOSE A FEE OF FOUR TIMES THE FEE FOR
 PLAN REVIEW, IF PLANS ARE REJECTED THREE
 OR MORE TIMES FOR REPEATED FAILURE TO
 CORRECT A CODE VIOLATION.
  
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS
 THE CODE REFERENCES GIVE ADDITIONAL INFO
 IF YOU HAVE ANY QUESTIONS PLEASE CALL:
 ROBERT BROWN(561) 659 8096 EXT 8499

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2002-04-15 Cont ID  
Sent By dpalmer Date 2002-04-03 Time 07:31 Rev Time 0.00
Received By rbrown Date 2002-04-15 Time 18:02 Sent To  
Notes
2002-04-15 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 659 8096 EXT 8499
  
 SBC = STANDARD BUILDING CODE 1997
 SBC*= STANDARD BUILD'G CODE (CITY AMEND)
 FBC = FLORIDA BUILDING CODE 2001
 FBC*= FLORIDA BUILD'G CODE (CITY AMEND)
  
 FOR CONSISTENCY, THE FOLLOWING COMMENTS
 ARE NUMBERED AS PER THE BUILDING PLAN
 REVIEW OF 3/7/02:
  
 3) FBC 424.2.17.1BARRIER TO SWIMMING
 POOL.THIS COMMENT HAS NOT BEEN
 PROPERLY ADDRESSED.THE 'REVISIONS'
 COLUMN ON SHEET A1.00 REFERS TO THE
 PROVISION OF A 36" HIGH BARRIER.THE
 TOP OF THE BARRIERS TO SWIMMING POOLS
 SHALL BE AT LEAST 48" ABOVE GRADE
 (FBC 424.2.17.1.1).THE NEW ACCESS
 GATES SHALL BE IN ACCORDANCE WITH
 FBC 424.2.17.1.8.THE WALLS, AND
 ASSOCIATED DOORS/WINDOWS, THAT FORM PART
 OF THE BARRIER SHALL BE IN ACCORDANCE
 WITH FBC 424.2.17.1.9.AMEND/ANNOTATE
 THE PLANS TO DEMONSTRATE COMPLIANCE.
  
 7) SBC* 1606.4.2PRODUCT APPROVALS.
 THIS COMMENT HAS NOT BEEN ADDRESSED.
 SUBMIT A PRODUCT APPROVAL NOTICE OF
 ACCEPTANCE FOR EACH OF THE NEW WINDOWS
 AND EXTERNAL DOORS (INCLUDING DOOR D108)
  
 8) SBC* 1606.4.2PRODUCT APPROVALS FOR
 'CUSTOM DOORS AND WINDOWS'.THIS
 COMMENT HAS NOT BEEN PROPERLY ADDRESSED.
 THE PRODUCT APPROVAL SUBMITTAL FORMS
 COMPLETED BY FRANK L BENNARDO, P.E. MUST
 BE SIGNED BY THE ENGINEER OF RECORD FOR
 THE PROJECT.
  
 11) SBC* 2308EXTERIOR STUD WALL.THIS
 COMMENT HAS NOT BEEN PROPERLY ADDRESSED.
 THE PARTITION LEGEND ON SHEET A2.10
 STILL REFERS TO 1/2" PLYWOOD SHEATHING
 FOR THE EXTERIOR STUD WALL.THE PLYWOOD
 SHEATHING SHALL BE MINIMUM 5/8" AS PER
 THE NOTE 8 ADDED TO SHEET A4.00.ALSO,
 DETAIL 8/A4.00 SHALL BE AMENDED (OR A
 DETAIL ADDED TO THE STRUCTURAL
 ENGINEER'S SHEETS) TO SHOW THE
 ATTACHMENT OF THE NEW STUD WALL TO THE
 EXISTING WALL, THE WORST CASE BEING IF
 THE POINT OF ABUTMENT DOES NOT COINCIDE
 WITH AN EXISTING STUD LOCATION.
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS
 THE CODE REFERENCES GIVE ADDITIONAL INFO
 IF YOU HAVE ANY QUESTIONS PLEASE CALL:
 ROBERT BROWN(561) 659 8096 EXT 8499

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-03-07 Cont ID  
Sent By pkrauss Date 2002-03-05 Time 11:00 Rev Time 0.00
Received By rbrown Date 2002-03-07 Time 19:40 Sent To  
Notes
2002-03-07 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 659 8096 EXT 8499
  
 SBC = STANDARD BUILDING CODE 1997
 SBC*= STANDARD BUILD'G CODE (CITY AMEND)
 FBC = FLORIDA BUILDING CODE 2001
 FBC*= FLORIDA BUILD'G CODE (CITY AMEND)
  
 1) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 2) THE SUBMITTED NOTICE OF COMMENCEMENT
 IS NOT VALID UNTIL RECORDED BY THE
 CLERK OF THE CIRCUIT COURT.
  
 3) FBC 424.2.17.1SHEET A1.00, SITE
 DEMOLITION PLAN.THE POOL FENCING IS
 SHOWN AS BEING REMOVED.THE SWIMMING
 POOL SHALL BE PROVIDED WITH A BARRIER.
 THIS IS A REQUIREMENT OF FLORIDA
 BUILDING CODE 2001, SECTION 424
 (SWMMING POOLS AND BATHING PLACES). THIS
 SECTION WAS SPECIFICALLY ADOPTED,
 STATEWIDE, ON JANUARY 2001.
  
 4) SBC 1005.4SHEET A3.10, WINDOW
 SCHEDULE, NOTE 9.THE NOTE STATES THAT
 THE REQUIRED NET CLEAR EGRESS WINDOW
 OPENING IS 20"WIDE X 22" HIGH.THIS
 SHOULD READ 20"WIDE X 24"HIGH.THE SILL
 HEIGHT SHALL BE NO MORE THAN 44" ABOVE
 THE FLOOR.
  
 5) SBC* 104.2SHOW WINDOW W101 ON THE
 EAST ELEVATION.AMEND THE SECOND FLOOR
 PLAN TO SHOW THE SECOND FLOOR WINDOW
 INDICATED ON THE NORTH ELEVATION.
  
 6) SBC* 104.2 DOOR SCHEDULE, SHEET A3.10
 THE MASTER BEDROOM DOOR REFERENCES D204
 AND D205 DO NOT CORRELATE WITH THE
 DETAILS GIVEN IN THE DOOR SCHEDULE.THE
 REFERENCES SHALL BE CORRECTED.
  
 7) SBC* 1606.4.2PRODUCT APPROVALS.
 SUBMIT A PRODUCT APPROVAL NOTICE OF
 ACCEPTANCE FOR EACH OF THE NEW WINDOWS
 AND EXTERNAL DOORS (INCLUDING DOOR D108)
  
 8) SBC* 1606.4.2PRODUCT APPROVAL. WITH
 REFERENCE TO THE FRANK L BENNARDO, P.E.
 LETTERS DATED FEBRUARY 4 AND 15, 2002,
 PRODUCT APPROVAL SUBMITTAL FORMS (BLANK
 COPIES ATTACHED TO THE COMMENTS) SHALL
 BE COMPLETED BY THE CERTIFYING ENGINEER
 AND THEN SIGNED BY THE ENGINEER OF
 RECORD FOR THE PROJECT.ALSO, THE
 EXISTING AND PROPOSED LOCATIONS OF THE
 'EXISTING SOLID CORE WOOD OUTSWING
 SINGLE ENTRY DOORS' ARE NOT STATED ON
 THE PLANS.AMEND THE PLANS TO CLARIFY.
  
 9) SBC104.1.1THE FRANK L BENNARDO, P.E
 LETTER DATED FEBRUARY 4, 2002 REQUIRES
 THE INSTALLATION OF "AN APPROVED IMPACT
 PROTECTION SYSTEM".A SEPARATE SHUTTER
 PERMIT APPLICATION WILL BE REQUIRED.
  
 10) SBC* 1606.4.2SBCCI EVALUATION OF
 THE GARAGE DOORS.THE SUBMITTED
 INSTALLATION DRAWING IS NOT LEGIBLE AS
 IT HAS BEEN REPEATEDLY COPIED AND/OR
 FAXED.SUBMIT A LEGIBLE COPY.
  
 11) SBC 2308THE PLYWOOD SHEATHING IN
 THE SECOND FLOOR EXTERIOR WALL SHALL BE
 MIN. 5/8" THICK (SBC TABLE 2308.2.2B).
 ALSO, PROVIDE DETAILS OF THE MEANS OF
 ATTACHMENT FOR THIS WALL WHERE IT ABUTTS
 THE WALL OF THE EXISTING BUILDING.
  
 12) SBC* 104.1.1 ROOF COVERING DETAILS
 HAVE NOT BEEN SUBMITTED.A SEPARATE
 ROOFING PERMIT APPLICATION WILL BE
 REQUIRED.
  
 13) SBC 2309.2SUBMIT A ROOF TRUSS
 LAYOUT AND DESIGN DATA.
  
 14) SBC* 2304.1.2THE TERMITE TREATMENT
 OF SOIL UNDER AND AROUND THE FOOTINGS
 AND SLABS ON-GRADE SHALL BE PERFORMED IN
 ACCORDANCE WITH THE REQUIREMENTS OF
 CHAPTERS 482 AND 487 FLORIDA STATUTES,
 AND SECTION 5E-14.106 FLORIDA
 ADMINISTRATIVE CODE.
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS
 THE CODE REFERENCES GIVE ADDITIONAL INFO
 IF YOU HAVE ANY QUERIES PLEASE CALL:
 ROBERT BROWN(561) 659 8096 EXT 8499

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-04-03 Cont ID  
Sent By dpalmer Date 2002-04-03 Time 07:31 Rev Time 0.00
Received By dpalmer Date 2002-04-03 Time 07:31 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2002-02-28 Cont ID  
Sent By dpalmer Date 2002-02-28 Time 06:49 Rev Time 0.00
Received By dpalmer Date 2002-02-28 Time 06:49 Sent To P
Notes
2002-02-28 00:00:00**************** UNSAT **************
  
 1) NOTE: SMOKE DETECTORS ARE REQUIRED
 INSIDE AND OUTSIDE ALL SLEEPING ROOMS.
 ALSO ON EACH LEVEL OF A MULTI-LEVEL
 DWELLING UNIT. ROOMS WITH BATHS AND OR
 CLOSETS ARE CONSIDERED SLEEPING ROOMS.
 PER NFPA-72 2-2.1.1.1.
 PLEASE NOTE THAT SD`S WILL BE REQ`D TO
 BE ADDED TO EXISTING BEDROOMS UPSTAIRS.
  
 2)NOTE: PLEASE NOTE MISSING GARAGE GFI
 PER 210-52G/210-8
  
 3)NOTE: PLEASE NOTE PANEL SCHEDULE SHOWS
 EXIST A/C AND NEW AHU& CU-2. PLEASE
 NOTE PLAN SHOWS NEW CU-1. PLEASE CLARIFY
  
 4)NOTE: PLEASE CLARIFY METER LOCATION,
 E1.00 SHOWS METER AT MAIN HOUSE AND
 RISER DIAGRAM SHOWS AT DETACHED "GUEST"
 HOUSE?
  
 5)NOTE: PLEASE NOTE MISSING GFI OUTLET
 FOR A/C CU`S. PER 309.2 MECH CODE.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW.
 561-659-8096 EXT 8372

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2002-03-05 Cont ID  
Sent By pkrauss Date 2002-03-05 Time 10:59 Rev Time 0.40
Received By pkrauss Date 2002-03-05 Time 10:23 Sent To B
Notes
2002-03-05 00:00:00 
 MECHANICAL PERMIT 02022172

Review Stop P PLUMBING
Rev No 2 Status P Date 2002-03-30 Cont ID  
Sent By jleech Date 2002-03-30 Time 10:35 Rev Time 0.50
Received By jleech Date 2002-03-30 Time 10:35 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-03-02 Cont ID  
Sent By dpalmer Date 2002-02-28 Time 06:49 Rev Time 0.33
Received By jleech Date 2002-03-02 Time 13:06 Sent To  
Notes
2002-03-02 00:00:00DENIED;
 1.PAGE P2.00 MASTER BATH. NO DRAIN TO
 BATH TUB.
 2.PAGE P3.00 TUB AND SHOWER MISSING FROM
 RISER DIAGRAM.
 3.PAGE P3.00 HORIZONTAL PIPE TO INCREASE
 TO 4" AFTER 3RD W/C ENTERS THE DRAIN-
 AGE SYSTEM. 94 SPC TABLE 714.1 NOTE 3.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 659-8096 EXT 8369

Review Stop Z ZONING
Rev No 1 Status P Date 2002-02-25 Cont ID  
Sent By sgraham Date 2002-02-25 Time 16:18 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***