Plan Review Details - Permit 02020511
Plan Review Stops For Permit 02020511
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2002-03-08 Cont ID  
Sent By rbrown Date 2002-03-08 Time 11:28 Rev Time 0.00
Received By rbrown Date 2002-03-08 Time 11:28 Sent To  
Notes
2002-03-08 00:00:00BUILDING PLAN REVIEW
 ******PROVISO*******
 ROBERT BROWN(561) 659 8096 EXT 8499
  
 --PROVISO--
 A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-02-20 Cont ID  
Sent By rbrown Date 2002-02-20 Time 19:50 Rev Time 0.00
Received By rbrown Date 2002-02-20 Time 19:49 Sent To  
Notes
2002-02-20 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 659 8096 EXT 8499
  
 UNTIL MARCH 1, 2001 EITHER STANDARD
 BUILDING CODE 1997 OR FLORIDA BUILDING
 CODE 2001 MAY BE USED.AS NEITHER CODE
 IS REFERENCED ON THE PLANS, THEY HAVE
 BEEN REVIEWED FOR COMPLIANCE WITH
 FLORIDA BUILDING CODE 2001.
  
 FBC = FLORIDA BUILDING CODE 2001
 FBC*= FLORIDA BUILD'G CODE (CITY AMEND)
  
 1) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) FBC 704.1.1THE LENGTH OF PARTITION
 BETWEEN THE STAIR WALL AND THE EXISTING
 DOOR TO THE EAST OF THE EAST STAIR IS
 NOT SHOWN AS ONE-HOUR FIRE-RATED.THIS
 IS NOW AN OCCUPANCY SEPARATION WALL.
 AMEND THE PLANS TO SHOW THE REQUIREMENT
 FOR A ONE-HOUR FIRE-RATED PARTITION.
  
 3) FBC 1004FILLING IN THE DOOR IN THE
 IN THE WALL TO THE EAST OF THE EAST
 STAIR RESULTS IN THE TENANCY EAST OF THE
 EAST STAIR BECOMING INDEPENDENT OF
 SUITE 400.AMEND THE PLANS TO SHOW THAT
 THE MEANS OF EGRESS FROM THE TENANCY IS
 FULLY COMPLIANT NOW THAT EGRESS THROUGH
 SUITE 400 IS NO LONGER AVAILABLE.
  
 4) FBC 1004.1.4THE EXIT DOORS FROM
 SUITE 400 ARE NOT REMOTE.THE DISTANCE
 BETWEEN THE DOORS SHALL BE NOT LESS THAN
 THE HALF THE MAXIMUM OVERALL DIMENSION
 OF THE AREA SERVED.AMEND THE PLANS TO
 DEMONSTRATE COMPLIANCE.
  
 5) FBC 2405.2THE GLAZING IN THE
 SIDELITE ADJACENT THE NEW SUITE 400
 ENTRANCE DOOR IS IN A 'HAZARDOUS
 LOCATION' AND IS REQUIRED TO BE SAFETY
 GLASS SATISFYING THE REQUIREMENTS OF THE
 CONSUMER PRODUCT SAFETY COMMISSION 16,
 CODE OF FEDERAL REGULATIONS, PART 1201
 (CPSC 16-CFR, PART 1201).SUBMIT
 DETAILS TO DEMONSTRATE COMPLIANCE.
  
 6) FBC 11-4.1.3(12)(A)SHEET 1, 'A.D.A
 CLEARNCES'.THE MAXIMUM HEIGHT OF
 ACCESSIBLE SHELVING AND RAILS IS SHOWN
 AS 54".THIS SHOULD READ 48" MAX AS
 SHOWN IN FIGURE 38.
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS
 THE CODE REFERENCES GIVE ADDITIONAL INFO
 IF YOU HAVE ANY QUERIES PLEASE CALL:
 ROBERT BROWN(561) 659 8096 EXT 8499

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-03-08 Cont ID  
Sent By dpalmer Date 2002-03-08 Time 11:32 Rev Time 0.00
Received By dpalmer Date 2002-03-08 Time 11:32 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2002-02-13 Cont ID  
Sent By dpalmer Date 2002-02-13 Time 20:40 Rev Time 0.00
Received By dpalmer Date 2002-02-13 Time 20:40 Sent To  
Notes
2002-02-13 00:00:00************* UNSAT *************
  
 1)NOTE: PLEASE CLARIFY RECEPTS SHOWN
 ON DEMO PLAN AND SHOWN AS EXISITNG ON
 NEW PLAN? ARE THESE SATYING "AS-IS"?
  
 2)NOTE: PLEASE SHOW CIRCUITING FOR ALL
 NEW REC/AND ANY LTS.
 PLEASE CORRELATE WITH A SUBMITTED PANEL
 SCHEDULE.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2002-02-15 Cont ID  
Sent By mcarsill Date 2002-02-15 Time 09:54 Rev Time 0.00
Received By mcarsill Date 2002-02-15 Time 09:53 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2002-02-19 Cont ID  
Sent By pkrauss Date 2002-02-19 Time 15:43 Rev Time 0.45
Received By pkrauss Date 2002-02-19 Time 15:37 Sent To  
Notes
2002-02-19 00:00:00 
 PROVISO:MECHANICAL PERMIT 02030882
  
 FAN SHUTDOWN BY DUCT SMOKE DETECTORS FOR
 UNITS SERVING AN AREA USED FOR EGRESS.
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop P PLUMBING
Rev No 1 Status N Date 2002-02-20 Cont ID  
Sent By rbrown Date 2002-02-20 Time 19:49 Rev Time 0.00
Received By rbrown Date   Time   Sent To  
Notes
***NONE***