Plan Review Details - Permit 02020235
Plan Review Stops For Permit 02020235
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2002-04-12 Cont ID  
Sent By jwitmer Date 2002-04-12 Time 15:55 Rev Time 4.00
Received By jwitmer Date   Time   Sent To  
Notes
2002-04-12 00:00:00"FOUNDATION / STEMWALL PROVISO!
 PERMIT # 02020235
 345 SUMMA STREET
  
 CONT: WHITING-TURNER
 TEL: (561) 832-4995
 FAX: (561) 832-0993
  
 ENGINEER: PAUL MARTINEZ
 TEL: (305) 461-2053 X 204
 FAX: (305) 461-3383
  
 THIS IS A THRESHOLD BUILDING AS PER
 STATE STATUTE 553.71.(7).
  
 THIS FOUNDATION PERMIT SHALL INCLUDE THE
 FOUNDATION AND STEMWALL TO (1) BLOCK
 ABOVE THE FLOOR SLAB, SLAB NOT INCLUDED.
  
 ELECTRICAL FOR FOUNDATION SHALL BE FOR
 PLACEMENT FOR UNDERGROUND, AND STEMWALL
 ONLY.
  
 THERE IS TO BE NO PIPING COVERED UNDER
 THIS PERMIT. THERE IS CONTRAVERSY OVER
 THE PLUMBING FIXTURE COUNT.
  
 SBC 104.4.3 AMEND. SPECIAL FOUNDATION
 PERMIT. WHEN APPLICATION FOR PERMIT TO
 ERECT A BUILDING HAS BEEN FILED AND PEND
 ING ISSUANCE OF SUCH PERMIT, THE BUILD-
 ING OFFICIAL MAY, AT HIS DISCRETION,
 ISSUE A SPECIAL PERMIT FOR THE FOUNDA-
 TION ONLY. THE HOLDER OF SUCH A SPECIAL
 PERMIT IS PROCEEDING AT THEIR OWN RISK
 AND WITHOUT ASSURANCE THAT A PERMIT FOR
 THE REMAINDER OF THE WORK WILL BE GRANT-
 ED NOR THAT CORRECTIONS WILL NOT BE RE-
 QUIRED IN ORDER TO MEET THE PROVISIONS
 OF THE TECHNICAL CODES.
  
 BUILDING PLAN REVIEW
 JIM WITMER
 (561)659-8096X8412

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2002-04-05 Cont ID  
Sent By jwitmer Date 2002-04-05 Time 07:01 Rev Time 2.00
Received By jwitmer Date 2002-04-05 Time 07:01 Sent To  
Notes
2002-04-05 00:00:00BUILDING PLAN REVIEW
 PERMIT # 02020235
 345 SUMMA ST
 CONT: WHITING TURNER
 TEL: 832-4995
  
 SBC= 1997 STANDARD BUILDING CODE
 SBC*= AMENDMENTS STANDARD BUILDING CODE
  
 1) SBC 104.2.2* A RECENT SURVEY (LESS
 THAN 1 YR. OLD)
 2) SBC 1804.2.7.1-2 SOILS TEST REQUIRED
 TO DETERMINE THE MINIMUM SAFE BEARING
 VALUE.
 3) THIS BUILDING WAS BROUGHT IN FOR PER-
 MIT IN A TIME PERIOD (JAN- FEB 2002),
 THE PLANS SHALL INDICATE UNDER WHAT
 PARAMETERS & ASSUMPTIONS THIS PROJECT
 WAS DESIGNED UNDER.1997 SBC OR 2001 FL
 CODE.SHEET S-1.0 DESIGN CRITERIA,
 WIND LOAD ASCE 7-98 WOULD INDICATE POSS-
 IBLY THE 2001 FL CODE, UNDER THIS CODE
 1606.1.7 INDICATES THE REQUIREMENTS THAT
 SHALL BE INDICATED ON THE DRAWINGS.
 WIND SPEED: INDICATED ON PLANS AS 130,
 UNDER THE SBC, THE WIND SPEED WAS 110MPH
 WHILE THE 2001 FL CODE IT IS 140MPH. THE
 PLAN INDICATES 130MPH?
 4)FLORIDA STATE STATUTE 553.71.(7)
 THIS BUILDING QUALIFIES AAS A "THRESHOLD
 BUILDING", ANY ASSEMBLY OCCUPAANCY WHICH
 EXCEEDS 5,000 SQ FT AND AN OCCUPANT CON-
 TENT OF GREATER THAN 500 PERSONS.
 5)DEPENDING IF THIS PLAN IS DESIGNED
 UNDER THE 97 CODE OR 2001 FL CODE THE
 ST STATUTE CHANGES BUT THE REQUIREMENT
 FOR A THRESHOLD INSPECTION PLAN BE FILED
 WITH THE BUILDING DEPARTMENT BY THE
 ENGIEENER OF RECORD. THE THRESHOLD
 COMPANY AND INSPECTOR SHALL MEET WITH
 ASSISTANT BUILDING OFFICIAL DON NEELY
 AS TO THE THRESHOLD INSPECTOR PROGRAM
 WITHIN THE CITY CORP. LIMITS.
 6) PLANS AARE TO BE SUBMITTED TO COUNTY
 FOR ASSESSMENT FOR IMPACT FEES, THEY
 SHOULD BE EXEMPT ZERO DOLLARS DUE.
 7) CONTRACTOR TO PAY STATE RADON FEES
 OF $177.50 TO CITY.
 8) SBC. 104.4.3* WHEN APPLICATION FOR
 PEREMIT TO ERECT OR ENLARGE A BUILDING
 HAS BEEN FILED AND PENDING ISSUANCE OF
 SUCH PERMIT, THE BUILDING OFFICIAL MAY,
 AT HIS/ HER DISCRETION ISSUE A SPECIAL
 PERMIT FOR FOUNDATION ONLY. THE HOLDER
 OF SUCH PERMIT IS PROCEEDING AT THEIR
 OWN RISK AND WITHOUT ASSURANCE THAT A
 PERMIT FOR THE REMAINDER OF THE WORK
 WILL BE GRANTED NOR THAT CORRECTIONS
 WILL NOT BE REQUIRED IN ORDER TO MEET
 PROVISIONS OF THE TECHNICAL CODES.
  
 BUILDING PLAN REVIEW
 JIM WITMER
 (561)659-8096 X 8412
 THREE (3) SETS OF PLANS REQUIRED,
 THRESHOLD BUILD!!!!

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-03-05 Cont ID  
Sent By rbrown Date 2002-03-05 Time 14:52 Rev Time 0.00
Received By rbrown Date 2002-03-05 Time 14:51 Sent To  
Notes
2002-03-05 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 659 8096 EXT 8499
  
 ---FOUNDATION PERMIT APPLICATION ONLY---
  
 1) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) SHEET S-1.0, STRUCTURAL NOTES.THE
 'ALLOWABLE SOIL BEARING CAPACITY' IS
 STATED AS 2500PSI.IF THIS WAS INTENDED
 TO READ 2500PSF, AMEND THE PLANS
 ACCORDINGLY.
  
 3) SHEET S-2.0, FOUNDATION PLAN.THE
 COLUMN ADJACENT TO THE MULTI-PURPOSE
 ROOM DOOR LEADING TO THE ASSOCIATED
 INNER ROOM (ASSUMED TO BE A STOREROOM)
 IS LABELLED AS A TYPE 6 COLUMN.THIS
 REFERENCE IS INCORRECT AS IT DOES NOT
 CORRELATE TO TYPE 6 AS SHOWN ON THE
 COLUMN SCHEDULE (SHEET S-1.0).
  
 4) SHEET S-2.0, FOUNDATION PLAN.THE
 COLUMN IN COMMENT (2) ABOVE, ALONG WITH
 ONE OTHER, IS SHOWN AS BEING FOUNDED ON
 ON A TYPE CF-405 FOOTING.THIS FOOTING
 REFERENCE IS NOT INCLUDED IN THE FOOTING
 SCHEDULE.AMEND THE PLAN OR SCHEDULE AS
 APPROPRIATE.
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS
 THE CODE REFERENCES GIVE ADDITIONAL INFO
 IF YOU HAVE ANY QUERIES PLEASE CALL:
 ROBERT BROWN(561) 659 8096 EXT 8499

Review Stop E ELECTRICAL
Rev No 2 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By btrobaug Date 2002-06-24 Time 16:36 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-02-26 Cont ID  
Sent By dpalmer Date 2002-02-26 Time 12:47 Rev Time 0.00
Received By dpalmer Date 2002-02-26 Time 12:47 Sent To  
Notes
2002-02-26 00:00:00FOUNDATION/SLAB ONLY.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status N Date 2002-02-21 Cont ID  
Sent By mcarsill Date 2002-02-21 Time 09:19 Rev Time 0.00
Received By mcarsill Date 2002-02-21 Time 09:18 Sent To  
Notes
2002-02-21 00:00:00FOUNDATION PERMIT ACCORDING TO
 APPLICATION FILED WITH CONSTRUCTION
 SERVICES DEPARTMENT.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 659-8096,EXT.8497
 835-2910

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2002-02-25 Cont ID  
Sent By ndenmark Date 2002-02-25 Time 15:22 Rev Time 0.25
Received By ndenmark Date 2002-02-25 Time 15:22 Sent To  
Notes
2002-02-25 00:00:00FOUNDATION PERMIT ONLY NO MECH INCLUDED

Review Stop P PLUMBING
Rev No 3 Status N Date 2002-04-12 Cont ID  
Sent By jwitmer Date 2002-04-12 Time 15:54 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
2002-04-12 00:00:00PLUMBING PULLED PLAN REQUIRED!!!!!!

Review Stop P PLUMBING
Rev No 2 Status F Date 2002-04-11 Cont ID  
Sent By kstevens Date 2002-04-11 Time 14:51 Rev Time 0.00
Received By kstevens Date 2002-04-11 Time 14:51 Sent To  
Notes
2002-04-11 00:00:00DENIED
 REFERENCE: SPC-94 - FACBC-97
  
 FOR FOUNDATION PERMIT
 1) PER PREVIOUS REVIEW: SUBMIT CALCULAT-
 IONS FOR MINIMUM FACILITIES PER SPC TAB.
 407 AND SEC. 407.1.3. CALCULATIONS SUB-
 MITTED NOT CLEAR. MULTIPLE OCCUPANCY -
 SHOW MIN. FAC FOR EACH OCCUPANCY.
 2) PER PREVIOUS REVIEW: SUBMIT STORM
 RISER DIAGRAM. INDICATE HOW STORM PIPING
 WILL BE RUN. WILL IT BE IN SLAB?
  
 --FOR BLDG PERMIT--
 3) PLANS SHALL BE ROUTED TO THE PALM
 BEACH COUNTY HEALTH UNIT, DIVISION OF
 ENVIRONMENTAL HEALTH. 901 EVERNIA STREET
 WPB FLA 33401. THIS SHALL BE DONE BEFORE
 RESUBMITTING FOR PLAN REVIEW.
 4) GREASE LINE SHOWS NEW LINE TO MEZZ.
 THIS NEW LINE SHALL RUN TO SANITARY.
 5) HAND SINKS IN KITCHEN DO NOT NEED TO
 BE INDIRECTLY DRAINED. PREVIOUS COMMENT
 #6, I DID NOT KNOW THEY WERE HAND SINKS.
 6) SHTS P-1/P-2 SANITARY RISER DIAGRAM
 DOES NOT REFLECT FLOOR PLAN.
 A) DRINKING FOUNTAINS BY MENS AND WOMEN
 REST ROOMS NOT ON RISER DIAGRAM.
 B) ARTS & CRAFTS TAKEN OFF BEFORE MENS
 ROOM ON FLOOR PLAN BUT NOT ON RISER DIA.
 C) OFFICE BATH ROOM TAKEN OFF AFTER
 DRAIN LINE TURNS TO MENS ROOM NOT REFLEC
 TED ON RISER DIAGRAM.
 7) GREASE TRAP SHALL BE SIZED BY RODNEY
 COMPO, ENVIRONMENTAL COMPLIANCE (561)
 837-4074. (SEE ATTACHED SHEET FOR APPRO-
 VED GREASE TRAP DETAIL)
 8) SHOWER BATH BY DANCE CLASS SHALL BE
 ACCESSIBLE PER FACBC-SEC 4.1.3(11)
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-02-25 Cont ID  
Sent By kstevens Date 2002-02-25 Time 19:38 Rev Time 1.50
Received By kstevens Date 2002-02-25 Time 19:38 Sent To  
Notes
2002-02-26 00:00:00DENIED
 REFERENCE: SPC-94-FACBC-97
  
 1) PLANS SHALL BE ROUTED TO THE PALM
 BEACH COUNTY HEALTH UNIT, DIVISION OF
 ENVIRONMENTAL HEALTH. 901 EVERNIA STREET
 WPB FLA 33401. THIS SHALL BE DONE BEFORE
 RESUBMITTING FOR PLAN REVIEW.
 2) PLEASE SUBMIT CALCULATIONS FOR MINI-
 MUM FACILITIES. USE SPC TABLE 407 AND
 SEC 407.1.3
 3) SHTS P-1/P-2 GREASE REISE DIA. DOES
 NOT REFLECT FLOOR PLAN. FLOOR PLAN SHOWS
 THREE FLOOR DRAINS TAKEN OFF FROM BLDG
 DRAIN. RISER DIAGRAM SHOWS ONE TAKEN OFF
 FROM BLDG DRAIN, AND ONE TAKEN OFF FROM
 BRANCH LINE AFTER 3 COMPARTMENT SINK.
 4) SHTS P-1/P-2 FLOOR SINK REQUIRED FOR
 INDIRECT WASTE FROM ICE MAKER. FLOOR
 DRAIN NOT APPROVED. SPC SEC 804.5
 5) SHTS P-1/P-2 JANITOR MOP SINK TO BE
 ON GREASE WASTE SYSTEM NOT SANITARY.
 6) SHTS P-1/P-2 ANY SINKS IN FOOD PREP
 AREA SHALL BE INDIRECT WASTE TO FLOOR
 SINK. SPC SEC 804.1
 7) SHTS P-1/P-2 SANITARY RISER DIAGRAM
 DOES NOT REFLECT FLOOR PLAN.
 A) SINK BEHIND HDCP LAV IN WOMENS REST
 ROOM ON RISER DIAGRAM NOT SHOWN ON FLOOR
 PLAN.
 B) DRINKING FOUNTAINS BY MENS AND WOMEN
 REST ROOMS ON FLOOR PLAN NOT SHOWN ON
 RISER DIAG.
 C) ARTS & CRAFTS TAKEN OFF BEFORE MENS
 ROOM ON FLOOR PLAN BUT NOT ON RISER DIA.
 D) CLEAN OUT AT CHANGE OF DIRECTION TO
 MENS ROOM MISSING ON RISER DIA.
 E) OFFICE BATH ROOM TAKEN OFF AFTER
 DRAIN LINE TURNS TO MENS ROOM NOT RE-
 FLECTED ON RISER DIA.
 F) FLOOR DRAIN BETWEEN URNAL AND W/C IN
 MENS ROOM SHOWN ON FLOOR PLAN NOT SHOWN
 ON RISER DIAGRAM.
 8) SHT ME-1 PLEASE SUBMIT STORM RISER
 DIAGRAM.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop Z ZONING
Rev No 1 Status P Date 2002-02-19 Cont ID  
Sent By sgraham Date 2002-02-19 Time 15:08 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***