Plan Review Details - Permit 02020068
Plan Review Stops For Permit 02020068
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2002-02-15 Cont ID  
Sent By hpiskura Date 2002-02-15 Time 10:52 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-02-12 Cont ID  
Sent By dpalmer Date 2002-02-12 Time 17:35 Rev Time 0.00
Received By dpalmer Date 2002-02-12 Time 17:35 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status N Date 2002-02-15 Cont ID  
Sent By hpiskura Date 2002-02-15 Time 10:52 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2002-02-06 Cont ID  
Sent By mcarsill Date 2002-02-06 Time 14:25 Rev Time 0.00
Received By mcarsill Date 2002-02-06 Time 14:25 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-03-04 Cont ID  
Sent By pkrauss Date 2002-03-04 Time 16:50 Rev Time 0.30
Received By pkrauss Date 2002-03-04 Time 16:50 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2002-02-14 Cont ID  
Sent By pkrauss Date 2002-02-14 Time 16:29 Rev Time 0.40
Received By pkrauss Date 2002-02-14 Time 16:23 Sent To  
Notes
2002-02-14 00:00:00*******************DENIED***************
  
  
 1.PROVIDE OUTSIDE AIR CALCULATIONS AS
 PER ASHRAE 62-89.
  
 2.CONDENSATE TO COMPLY WITH COUNTYWIDE
 AMENDMENTS 1994 SPC 804.3.(SHALL
 NOT TERMINATE INTO SANITARY).
  
 3.OVERFLOW PROTECTION - AUXILIARY
 DRAIN LINE SHALL TERNIMATE AT A
 CONSPICUOUS POINT TO SERVE AS AN
 ALARM THAT REGULAR DRAIN IS
 RESTRICTED.
  
 SEPARATE PERMIT REQUIRED FOR ANY HOOD,
 FIRE SUPRESSION, AND WALK-IN
 COOLER/FREEZERS.PLEASE PROVIDE PLANS
 AND MANUFACTURER SUBMITTAL DATA WITH
 PERMIT APPLICATION.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop P PLUMBING
Rev No 3 Status P Date 2002-03-26 Cont ID  
Sent By kstevens Date 2002-03-26 Time 10:02 Rev Time 0.00
Received By kstevens Date 2002-03-26 Time 10:02 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2002-03-08 Cont ID  
Sent By kstevens Date 2002-03-08 Time 18:52 Rev Time 0.50
Received By kstevens Date 2002-03-08 Time 18:52 Sent To  
Notes
2002-03-08 00:00:00DENIED
 REFERENCE: SPC-94 - FACBC-97
  
 1) FROM PREVIOUS REVIEW - WATER HEATER
 SHALL REQUIRE A PERMINATE SHIPS LADDER
 FOR ALL WATER HEATERS ON SHELVES OR
 ABOVE CEILINGS. PLEASE SHOW DETAILS.
  
 2) FROM PREVIOUS REVIEW - SHTS P1/P2
 FLOOR PLAN WASTE AND VENT AND SANT RISER
 DIAGRAM, SEPARATE SANITARY AND GREASY
 WASTE LINES REQUIRED. SAMPLE POINT SHALL
 BE OUTSIDE BLDG AND THEN TIE GREASE INTO
 SANITARY AFTER SAMPLE POING.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-02-12 Cont ID  
Sent By kstevens Date 2002-02-12 Time 18:48 Rev Time 1.25
Received By kstevens Date 2002-02-12 Time 18:48 Sent To  
Notes
2002-02-12 00:00:00DENIED
 REFERENCE: SPC-94-FACBC-97
  
 1) SHT A-2 EQUIPMENT SCHED. 21A LISTED
 BUT NOT FOUND ON FLOOR PLAN, PLEASE
 CLAIRFY.
 2) SHT A-2 EQUIP. SCHED. 34 WATER FILTER
 SHALL MEET NSF REQUIREMENTS. PLEASE FUR-
 NISH MANUFACTURE'S INFORMATION.
 3) SHT A-2 EQUIP. SCHED. 7 W/HEATER REQ-
 UIRES A PERMINATE SHIPS LADDER TO ASSURE
 READILY ACCESSIBLE. SHOW DETAILS.
 4) SHT A-3 WATER HEATER SUPPORT DETAIL,
 1/2" PAN DRAIN SHOWN. 1" MINIMUM DRAIN
 REQUIRED. SPC SEC 507.8.2
 5) SHT P-1 FLOOR PLAN WASTE & VENT, SEP-
 ARATE SANITARY AND GREASE LINES REQUIRED
 6) SHT P-1 GREASE TRAP CALCULATIONS.
 MINIMUM SIZE GREASE TRAP IS 750 GALS.
 GREASE TRAP TO BE SIZED BY ROD COMPO,
 ENVIRONMENTAL COMPLIANCE, (561) 837-4074
 WASTE ORD. #2938-96
 7) BACKFLOW REQUIRED ON WATER SERVICE
 SHALL BE MAX. 4' AFF FOR SERVICE. (SHT
 P-1 KEY NOTE #2).
 8) SHTS P-1/P-2 GREASE TRAP INSIDE BLDG.
 NOT APPROVED.
 9) SHT P-2 WASTE & VENT RISER DIAGRAM,
 3-COMPARTMENT SINK SHALL HAVE TRAPS ON
 EACH COMPARTMENT.
 10 SHT P-2 WATER RISER DIAGRAM, WATER
 FILTER NOT SHOWN.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop Z ZONING
Rev No 1 Status N Date 2002-02-15 Cont ID  
Sent By hpiskura Date 2002-02-15 Time 10:52 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
***NONE***