Plan Review Details - Permit 02011248
Plan Review Stops For Permit 02011248
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2002-03-11 Cont ID  
Sent By btrobaug Date 2002-03-11 Time 13:03 Rev Time 2.00
Received By lsmith Date   Time   Sent To  
Notes
2002-03-11 00:00:00************BUILDING PROVISO************
  
 1. PROVIDESITE SPECIFIC ENGINEERING
 WITH ALL REQUIRED DRAWINGS FOR WINDOWS,
 SLIDERS & FIXED GLASS.
  
 2. MUST PAY IMPACT FEES
  
 3.PROPERTY LOCATED IN "AO" FLOOD ZONE
 NEED ELEVATION CERTIFICATE BEFORE C/O
  
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH, BUILDING PLANS EXAMINER
 659-8096 EXT. 8394

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2002-08-29 Cont ID  
Sent By btrobaug Date 2002-08-29 Time 07:56 Rev Time 0.50
Received By btrobaug Date 2002-08-29 Time 06:53 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-07-08 Cont ID  
Sent By btrobaug Date 2002-07-08 Time 12:13 Rev Time 0.00
Received By btrobaug Date 2002-07-08 Time 11:36 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-03-11 Cont ID  
Sent By btrobaug Date 2002-03-11 Time 13:03 Rev Time 0.00
Received By btrobaug Date 2002-02-08 Time 13:58 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2002-02-07 Cont ID  
Sent By hmoser Date 2002-02-07 Time 17:12 Rev Time 0.33
Received By hmoser Date 2002-02-07 Time 17:12 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2002-09-17 Cont ID  
Sent By kstevens Date 2002-09-17 Time 13:13 Rev Time 0.00
Received By kstevens Date 2002-09-17 Time 13:13 Sent To  
Notes
2002-09-17 00:00:00REVISION OK - SANT. RISER DIAGRAM

Review Stop P PLUMBING
Rev No 2 Status F Date 2002-09-07 Cont ID  
Sent By kstevens Date 2002-09-07 Time 08:15 Rev Time 0.00
Received By kstevens Date 2002-09-07 Time 08:15 Sent To  
Notes
2002-09-07 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
  
 1) ONLY THE FIXTURES WITHIN THE BATHROOM
 GROUP SHALL CONNECT TO THE WET-VENTED
 HORIZONTAL BRANCH DRAIN. ANY ADDITIONAL
 FIXTURES SHALL DISCHARGE DOWNSTREAM OF
 THE WET VENT. 909.1 - THE LAUNDRY TRAY
 SHALL NOT DRAIN THROUGH THE BATHROOM
 GROUP.
 2) SANITARY RISER SHALL REFLECT THE
 FLOOR PLAN. PLEASE SEE RED LINE CORRECT-
 IONS ON REVISION SHEET AND MAKE NECESS-
 ARY CHANGES.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-02-02 Cont ID  
Sent By jleech Date 2002-02-02 Time 12:33 Rev Time 0.33
Received By jleech Date 2002-02-02 Time 12:32 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2002-01-30 Cont ID  
Sent By sgraham Date 2002-01-30 Time 16:00 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***