Plan Review Details - Permit 02011150
Plan Review Stops For Permit 02011150
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2002-05-09 Cont ID  
Sent By lsmith Date 2002-05-09 Time 16:33 Rev Time 0.25
Received By lsmith Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2002-03-18 Cont ID  
Sent By lsmith Date 2002-03-18 Time 09:13 Rev Time 0.75
Received By lsmith Date   Time   Sent To  
Notes
2002-03-18 00:00:00*************PROVISO************
  
 THE FOLLOWING ITEMS MUST BE CORRECTED:
  
 1. ALL DRAWING MUST REFERENCE THE FBC 2
 2001.
  
 2. A DETAIL OF THE CONCRETE SLAB FOR POO
 L EQUIPMENT AND ANCHORING DETAIL SHOWN.
  
  
 ALL FUTURE PERMIT APPLICATIONS FOR POOL
 MUST BE CORRECTED AND SHOW THE CORRECT I
 NFORMATION.WE WILL NO LONGER MAKE CORR
 ECTIONS ON PLANS & ISSUE WITH PROVISO DU
 E TO REFERENCES OF IMPROPER CODES.
  
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH, BUILDING PLANS EXAMINER
 659-8096 EXT. 8394

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-05-06 Cont ID  
Sent By btrobaug Date 2002-05-06 Time 07:55 Rev Time 0.00
Received By btrobaug Date 2002-05-06 Time 07:55 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-03-18 Cont ID  
Sent By lsmith Date 2002-03-18 Time 09:18 Rev Time 0.00
Received By lsmith Date 2002-03-04 Time 14:55 Sent To  
Notes
2002-03-18 00:00:00PER WRT 3/4/02 SEE APPLICATION

Review Stop P PLUMBING
Rev No 3 Status P Date 2002-05-04 Cont ID  
Sent By btrobaug Date 2002-05-06 Time 07:55 Rev Time 0.00
Received By kstevens Date 2002-05-04 Time 09:12 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2002-04-12 Cont ID  
Sent By kstevens Date 2002-04-12 Time 19:25 Rev Time 0.00
Received By kstevens Date 2002-04-12 Time 19:25 Sent To  
Notes
2002-04-12 00:00:00DENIED
 REFERENCE: FBC-2001 424.2 SWIMMING POOLS
  
 1) CHANGES TO A SIGNED AND SEALED SET OF
 PLANS SHALL NOT BE PENNED IN. NEW PLANS
 WITH CHANGES ON THEM REQUIRED.
 2) GENERAL NOTES #14,PLEASE ADD TO NOTES
 FBC-2001 SEC 424.2.6.1 ENGINEERING
 DESIGN, CONSTRUCTION AND WORKMANSHIP.
 ANSI/NSPI-5.
 3)
 FBC-2001 SEC 424.2.6.6.2 SHOW COMPLIANCE
 WITH ANSI/ASME A112.19.8M. PROVIDE MODEL
 NUMBER AND MANUF INFO FOR VAC LOCK.
 (GIVE DETAIL OR ADD NOTE)(SUBMITTAL)
 4)
 FBC-2001 SEC 424.2.9 WATER SUPPLY, LOCAL
 ORD. #2853-95, BACKFLOW REQUIRED ON
 WATER SERVICE. (ADD TO NOTES)
 5)
 FBC-2001 SEC 424.2.13.2JOINTS AND CON-
 NECTIONS, FBC PLMG SEC 605.21, PURPLE
 PRIMER REQUIRED ON PVC PIPING. (ADD TO
 NOTES)
  
 ADD ABOVE TO NOTES, GIVE DETAILS, OR
 SUBMITTALS FOR PLAN REVIEW.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-03-03 Cont ID  
Sent By pschmitz Date 2002-03-03 Time 05:56 Rev Time 1.50
Received By pschmitz Date   Time   Sent To  
Notes
2002-03-03 00:00:00PLUMBING PLAN REVIEW,FBC 2001, DENIED
 (1) GENERAL NOTES (14) DESIGN IS NOT BY
 WPB SWIMMING POOL CODE, SEE FBC 2001".
 SEC 424.2.6
 (2) SEC 424.2.6.6.2 SUCTION FITTINGS,
 CLEANING LINE.
 (3) SEC 424..2.7.2 SHOW A DETAIL OF MOUN
 TING AND ANCHORING POOL,SPA EQUIPMENT.
 (4) 424.2.9 WATER SUPPLY,LOCAL ORDINANCE
 #2853-95 BACK FLOW PREVENTER REQUIRED ON
 WATER SERVICE.
 (5) SEC 424.2.13.2 JOINTS, CONNECTIONS,
 PURPLE PRIMER REQUIRED ON PVC PIPING.
 FBC-2001 PLUMBING SEC605.21
 END OF COMMENTSPAUL SCHMITZ
 QUESTIONS561-659-8096X8233

Review Stop Z ZONING
Rev No 2 Status P Date 2002-02-15 Cont ID  
Sent By sgraham Date 2002-02-15 Time 08:29 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2002-01-30 Cont ID  
Sent By sgraham Date 2002-01-30 Time 10:45 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***