Plan Review Details - Permit 02010043
Plan Review Stops For Permit 02010043
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2002-02-22 Cont ID  
Sent By hpiskura Date 2002-02-22 Time 10:06 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-01-16 Cont ID  
Sent By hpiskura Date 2002-01-16 Time 08:43 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
2002-01-16 00:00:00SEE COMMENTS ON 02010047

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-02-22 Cont ID  
Sent By dpalmer Date 2002-02-22 Time 12:41 Rev Time 0.00
Received By dpalmer Date 2002-02-22 Time 12:41 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2002-01-08 Cont ID  
Sent By dpalmer Date 2002-01-08 Time 06:18 Rev Time 0.00
Received By dpalmer Date 2002-01-08 Time 06:18 Sent To  
Notes
2002-01-08 00:00:00****************** UNSAT ***************
  
  
 1)NOTE: PLEASE SEE NOTES FOR ELECTRICAL
 RISER.
 PLEASE NOTE #1 SHOWS AN EQUIPMENT GRND
 BEING INSTALLED TO PANEL "A", PLEASE
 CLARIFY IF THIS FEED IS COIMING FROM
 FPL OR OTHER SERVICE MEANS?
 IF FROM FPL, NO EQUIPMENT GROUNDING
 UNTIL AFTER FIRST MEANS OF DISCONNETC.
 THIS IS PARALELLING THE NEUTRAL.
  
 2)NOTE: PLEASE NOTE THAT THE GROUNDING
 ELECTRODE CONDUCTOR IS BEING SHOWN AS
 #4, PLEASE SEE 250-66 FOR SERVICE
 ENTRANCE CONDUCTOR SIZE.
  
 3)NOTE: PLEASE CHECK WITH FIRE REVIEW,
 LIGHTING IN BATHS SHOWING NOTE THAT TIME
 "ON" IS ONLY FROM 9AM-6AM. PLEASE NOTE
 LIFE SAFETY ISSUES AND IF THERE MIGHT BE
 ANY CLEANING PERSONNEL IN AFTER THE
 NORMAL OPERATING HOURS? PLEASE CALL
 MIKE CARSILLO AT EXT 8497
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop ENG ENGINEERING CSD
Rev No 1 Status N Date 2002-01-08 Cont ID  
Sent By rbrown Date 2002-01-08 Time 08:23 Rev Time 1.00
Received By rbrown Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2002-02-01 Cont ID  
Sent By lmartine Date 2002-02-01 Time 09:51 Rev Time 0.00
Received By mcarsill Date 2002-02-01 Time 12:17 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status N Date 2002-01-08 Cont ID  
Sent By rbrown Date 2002-01-08 Time 08:26 Rev Time 1.00
Received By rbrown Date   Time   Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2002-01-30 Cont ID  
Sent By pkrauss Date 2002-01-30 Time 13:08 Rev Time 0.25
Received By pkrauss Date   Time   Sent To  
Notes
2002-01-30 00:00:00 
 NO MECHANICAL PLANS SUBMITTED FOR
 REVIEW.PLEASE PROVIDE PLANS WITH
 MECHANICAL PERMIT APPLICATION.
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388

Review Stop P PLUMBING
Rev No 2 Status P Date 2002-01-24 Cont ID  
Sent By dpalmer Date 2002-02-22 Time 12:41 Rev Time 1.00
Received By kstevens Date 2002-01-24 Time 17:41 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-01-18 Cont ID  
Sent By kstevens Date 2002-01-18 Time 18:00 Rev Time 1.00
Received By kstevens Date 2002-01-18 Time 18:00 Sent To  
Notes
2002-01-18 00:00:00DENIED
 REFERENCE: SPC-94-FACBC-97
  
 1) SHT P1.2 WATER HEATER DETAIL. RELIEF
 LINE AND PAN DRAIN TO BE PIPED SEPARATE
 TO FLOOR SINK. SPC SEC 507.8.4 - 1" FOR
 PAN DRAIN (SEC 507.8.2), FULL SIZE FOR
 RELIEF LINE.
  
 2) SHT P1.2 WATER HEATER DETAIL/SANITARY
 RISER DIAGRAM. FUNNEL FLOOR DRAIN NOT
 APPROVED, ALL INDIRECT WASTE TO FLOOR
 SINK. SPC SEC 804.5.
  
 3) SHT P1. WATER RISER DIAGRAM. AIR
 CHAMBERS SHOWN. PLEASE SHOW WATER HAMMER
 ARRESTORS, (NOTE #10), NEAR FIXTURES NOT
 ON TOP OF DROP. LOCATE ACCORDING TO PDI-
 WH 201 AND MANUFACTURES INSTALLATION IN-
 STRUCTIONS, IN AN "EFFECTIVE RANGE".
 SHOW DETAILS.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop Z ZONING
Rev No 1 Status P Date 2002-01-03 Cont ID  
Sent By sgraham Date 2002-01-03 Time 09:19 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***