Plan Review Stops For Permit 02010043 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2002-02-22 |
|
|
Cont ID |
|
Sent By |
hpiskura |
Date |
2002-02-22 |
Time |
10:06 |
Rev Time |
0.00 |
Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2002-01-16 |
|
|
Cont ID |
|
Sent By |
hpiskura |
Date |
2002-01-16 |
Time |
08:43 |
Rev Time |
0.00 |
Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2002-01-16 00:00:00 | SEE COMMENTS ON 02010047 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2002-02-22 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-02-22 |
Time |
12:41 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2002-02-22 |
Time |
12:41 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2002-01-08 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-01-08 |
Time |
06:18 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2002-01-08 |
Time |
06:18 |
Sent To |
|
|
Notes |
2002-01-08 00:00:00 | ****************** UNSAT *************** | | | | | | 1)NOTE: PLEASE SEE NOTES FOR ELECTRICAL | | RISER. | | PLEASE NOTE #1 SHOWS AN EQUIPMENT GRND | | BEING INSTALLED TO PANEL "A", PLEASE | | CLARIFY IF THIS FEED IS COIMING FROM | | FPL OR OTHER SERVICE MEANS? | | IF FROM FPL, NO EQUIPMENT GROUNDING | | UNTIL AFTER FIRST MEANS OF DISCONNETC. | | THIS IS PARALELLING THE NEUTRAL. | | | | 2)NOTE: PLEASE NOTE THAT THE GROUNDING | | ELECTRODE CONDUCTOR IS BEING SHOWN AS | | #4, PLEASE SEE 250-66 FOR SERVICE | | ENTRANCE CONDUCTOR SIZE. | | | | 3)NOTE: PLEASE CHECK WITH FIRE REVIEW, | | LIGHTING IN BATHS SHOWING NOTE THAT TIME | | "ON" IS ONLY FROM 9AM-6AM. PLEASE NOTE | | LIFE SAFETY ISSUES AND IF THERE MIGHT BE | | ANY CLEANING PERSONNEL IN AFTER THE | | NORMAL OPERATING HOURS? PLEASE CALL | | MIKE CARSILLO AT EXT 8497 | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
N |
Date |
2002-01-08 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2002-01-08 |
Time |
08:23 |
Rev Time |
1.00 |
Received By |
rbrown |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2002-02-01 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2002-02-01 |
Time |
09:51 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2002-02-01 |
Time |
12:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
N |
Date |
2002-01-08 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2002-01-08 |
Time |
08:26 |
Rev Time |
1.00 |
Received By |
rbrown |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2002-01-30 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2002-01-30 |
Time |
13:08 |
Rev Time |
0.25 |
Received By |
pkrauss |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2002-01-30 00:00:00 | | | NO MECHANICAL PLANS SUBMITTED FOR | | REVIEW.PLEASE PROVIDE PLANS WITH | | MECHANICAL PERMIT APPLICATION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT 659-8096 | | EXT. 8388 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2002-01-24 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-02-22 |
Time |
12:41 |
Rev Time |
1.00 |
Received By |
kstevens |
Date |
2002-01-24 |
Time |
17:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2002-01-18 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2002-01-18 |
Time |
18:00 |
Rev Time |
1.00 |
Received By |
kstevens |
Date |
2002-01-18 |
Time |
18:00 |
Sent To |
|
|
Notes |
2002-01-18 00:00:00 | DENIED | | REFERENCE: SPC-94-FACBC-97 | | | | 1) SHT P1.2 WATER HEATER DETAIL. RELIEF | | LINE AND PAN DRAIN TO BE PIPED SEPARATE | | TO FLOOR SINK. SPC SEC 507.8.4 - 1" FOR | | PAN DRAIN (SEC 507.8.2), FULL SIZE FOR | | RELIEF LINE. | | | | 2) SHT P1.2 WATER HEATER DETAIL/SANITARY | | RISER DIAGRAM. FUNNEL FLOOR DRAIN NOT | | APPROVED, ALL INDIRECT WASTE TO FLOOR | | SINK. SPC SEC 804.5. | | | | 3) SHT P1. WATER RISER DIAGRAM. AIR | | CHAMBERS SHOWN. PLEASE SHOW WATER HAMMER | | ARRESTORS, (NOTE #10), NEAR FIXTURES NOT | | ON TOP OF DROP. LOCATE ACCORDING TO PDI- | | WH 201 AND MANUFACTURES INSTALLATION IN- | | STRUCTIONS, IN AN "EFFECTIVE RANGE". | | SHOW DETAILS. | | | | REVIEW BY KEN STEVENS | | (561) 659-8096 EXT 8377 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2002-01-03 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2002-01-03 |
Time |
09:19 |
Rev Time |
0.25 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|