Plan Review Stops For Permit 01121731 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2002-06-06 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2002-06-06 |
Time |
17:12 |
Rev Time |
0.50 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2002-06-06 00:00:00 | | | BUILDING PLAN REVIEW | | PERMIT: 01121731 | | ADD: 6211 EATON STREET | | CONT: CONTINENTAL HOMES | | TEL: (305)525-4364 | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | *******REVISION******* | | DATED 4/18/02 | | PROVISO; | | FIRE, NO OCCUPANCY WILL BE ON 2ND FLOOR. | | PORTABLE FIRE EXTINGUSHER SHALL BE | | PROVIDED FOR THE SALES OFFICE. | | | | MECH, NOTE ON PLAN FOR REMOVING A/C IN | | GARAGE AT END OF TEMP OFFICE,02010983 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2002-04-02 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2002-04-02 |
Time |
06:59 |
Rev Time |
1.00 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2002-04-02 00:00:00 | BUILDING PLAN REVIEW | | PERMIT # 01121731-REVISION | | 6211 EATON STREET | | CONTINENTAL HOMES | | (954)428-4854 ROBIN | | | | SBC=1997 STANDARD BUILDING CODE | | | | 1- THE CONVERSION FROM GARAGE TO SALES | | OFFICE SHALL REQUIRE ADDITIONAL | | PRODUCT APPROVAL FOR THE DOUBLE FRENCH | | DOORS. SINCE THEY ARE GLAZED OPENINGS | | INDICATE ALSO THE HURRICANE PROTECTION | | REQUIRED FORTHESE OPENINGS. | | 2)- THE GARAGE ENETRY SHOWS A 6" DROP, | | IF THIS WAS TO BE A GARAGE WOULDN'T IT | | BE A 11/2" DEPRESSION FOR THE GARAGE | | DOOR? THERE MAY BE A CHANGE OF GRADE NOT | | GREATER THAN 1/2" FL HANDICAPPED CODE | | 4.3.8. THIS CONDITION ALSOSHALL EXIST | | AT THE FRONT DOOR. REMEMBER RAMPS ARE TO | | LANDINGS AT TOP AND BOTTOM OF RAMP. | | RAMPS GREATER THAN 6" REQUIRES HANDRAILS | | 4.8.5. | | 3)- 4.5.1 GROUND AND FLOOR SURFACES | | ALONG ACCESSIBLE ROUTES AND IN ACCESS- | | IBLE ROOMS INCLUDING FLOORS, WALKS, AND | | RAMPS, SHALL BE STABLE, FIRM, SLIP | | RESISANT, ADDAAG A-5 A STATIC COEFFIC- | | IENT OF FRICTION OF 0.6 FOR ACCESSIBLE | | ROUTES AND 0.8 FORRAMPS. | | 4)- THE POWDER ROOM, INSWING DOOR ACCESS | | CODE 4.22.2 ALL DOORS TO ACCESSIBLE | | TOILET ROOMS SHALL NOT SWING INTO THE | | CLEAR FLOOR SPACE REQUIRED FOR ANY | | FIXTURE. | | 5)- STRUCTURAL STRENGTH 4.26.3.(1) | | BENDING STRESS IN A GRAB BAR INDUCED BY | | THE BENDING MOMENT FROM THE APPLICATION | | OF 250 LBF. | | BUILDING PLAN REVIEW | | JIM WITMER | | (651)659-8096 X8412 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2001-12-10 |
|
|
Cont ID |
|
Sent By |
lsmith |
Date |
2002-01-31 |
Time |
10:09 |
Rev Time |
0.00 |
Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2002-01-31 00:00:00 | PER JW 12/10/01 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2002-05-24 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2002-05-25 |
Time |
12:25 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2002-05-24 |
Time |
06:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2002-04-02 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2002-04-02 |
Time |
08:39 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2002-04-02 |
Time |
08:39 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2002-03-12 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-03-12 |
Time |
08:49 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2002-03-12 |
Time |
08:49 |
Sent To |
|
|
Notes |
2002-03-12 00:00:00 | ************ UNSAT ***************** | | | | 1)NOTE: PLEASE SEE FIRE REVIEW COMMENTS, | | FOR ANY EXIT/EM LIGHTING REQ`MENTS. | | | | 2)NOTE: PLEASE CLARIFY WHAT HAPPENED TO | | UPSTAIRS ELECTRICAL? | | | | 3)NOTE: PLEASE NOTE MISSING EQUIPMENT | | GROUNDING CONDCUTOR BETWEEN FIRST MEANS | | OF DISCONNECT AND PANEL. SIZE PER | | 250-122 | | | | 4)NOTE: PLEASE CLARIFY IF USE WILL BE | | GOING BACKTO RESIDENTIAL? PLEASE NOTE | | LOAD CALCUALTIONS ARE SHOWN FOR RES AND | | NOT COMMERCIAL USE? | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-659-8096 EXT8372 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2002-01-30 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-01-30 |
Time |
13:44 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2002-01-30 |
Time |
13:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2002-06-05 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2002-06-05 |
Time |
10:29 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2002-06-05 |
Time |
10:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
F |
Date |
2002-03-21 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2002-03-21 |
Time |
13:32 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2002-03-21 |
Time |
13:32 |
Sent To |
|
|
Notes |
2002-03-21 00:00:00 | A) EXIT SIGNS AND EMERGENCY LIGHTS | | ARE REQUIRED SINCE THE SPACE WILL | | FUNCTION AS A BUSINESS OCCUPANY. | | B) WILL OCCUPANCY BE PRESENT ON THE | | SECOND FLOOR. | | C) PORTABLE FIRE EXTINGUISHERS WILL BE | | REQUIRED. | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | 659-8096,EXT.8497 | | 835-2910 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2001-10-16 |
|
|
Cont ID |
|
Sent By |
lsmith |
Date |
2002-01-31 |
Time |
10:10 |
Rev Time |
0.00 |
Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2002-01-31 00:00:00 | PER MEC LS |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2002-05-28 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2002-05-28 |
Time |
16:32 |
Rev Time |
0.35 |
Received By |
pkrauss |
Date |
2002-05-28 |
Time |
16:27 |
Sent To |
|
|
Notes |
2002-05-28 00:00:00 | MECHANICAL PERMIT 02010983 | | | | REVISION - NOTE STATING A/C TO BE RE- | | MOVED FROM THE GARAGE PRIOR TO FINAL. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2002-03-12 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2002-03-12 |
Time |
11:55 |
Rev Time |
0.45 |
Received By |
pkrauss |
Date |
2002-03-12 |
Time |
11:55 |
Sent To |
|
|
Notes |
2002-03-12 00:00:00 | | | PROVISO: | | | | PRIOR TO FINAL C.O., SUBMIT REVISION | | INDICATING THE DUCTWORK HAS BEEN | | REMOVED FROM THE GARAGE AREA. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT 659-8096 | | EXT. 8388. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2002-01-31 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2002-01-31 |
Time |
10:38 |
Rev Time |
0.05 |
Received By |
pkrauss |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2002-01-31 00:00:00 | APPROVED ON MASTER 01091364 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2002-05-25 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2002-05-25 |
Time |
12:25 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2002-05-25 |
Time |
12:25 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2002-04-02 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2002-04-02 |
Time |
13:49 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2002-04-02 |
Time |
13:49 |
Sent To |
|
|
Notes |
2002-04-02 00:00:00 | DENIED | | REFERENCE: SPC-94 - FACBC-97 | | | | 1) SHT 1 BATHROOM DOOR SHALL NOT SWING | | INTO CLEAR FLOOR SPACE OR UNOBSTRUCTED | | TURNING RADIUS. SEC 4.22.2 | | 2) SHT 1 W/C SHALL BE 1'6" TO CENTER OFF | | WALL NOT 2'2" AS SHOWN. | | 3) SHT 1 SHOW DETAIL FOR HDCP FIXTURES | | W/C AND LAV PER SECS 4.16, 4.16.2, | | 4.16.3, 4.16.5 AND 4.19, 4.19.2, 4.19.3, | | 4.19.4, 4.19.5 | | 4) SHT 1 TABLE 407 REQUIRES A DRINKING | | FOUNTAIN. | | 5) SHT 1 SANT RISER SHOWS A DRY HORIZON- | | TAL VENT. PER SEC 906.2.1 THIS IS NOT | | APPROVED. | | | | REVIEW BY KEN STEVENS | | (561) 659-8096 EXT 8377 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2002-01-31 |
|
|
Cont ID |
|
Sent By |
lsmith |
Date |
2002-01-31 |
Time |
10:10 |
Rev Time |
0.00 |
Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2002-01-31 00:00:00 | PER KS 10/11/01 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2002-01-29 |
|
|
Cont ID |
|
Sent By |
aneil |
Date |
2002-01-29 |
Time |
15:32 |
Rev Time |
1.00 |
Received By |
aneil |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2002-01-29 00:00:00 | PASSED PER SHIRLEY 1-29-2002 AN |
|
|