Plan Review Details - Permit 01121731
Plan Review Stops For Permit 01121731
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2002-06-06 Cont ID  
Sent By jwitmer Date 2002-06-06 Time 17:12 Rev Time 0.50
Received By jwitmer Date   Time   Sent To  
Notes
2002-06-06 00:00:00 
 BUILDING PLAN REVIEW
 PERMIT: 01121731
 ADD: 6211 EATON STREET
 CONT: CONTINENTAL HOMES
 TEL: (305)525-4364
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 *******REVISION*******
 DATED 4/18/02
 PROVISO;
 FIRE, NO OCCUPANCY WILL BE ON 2ND FLOOR.
 PORTABLE FIRE EXTINGUSHER SHALL BE
 PROVIDED FOR THE SALES OFFICE.
  
 MECH, NOTE ON PLAN FOR REMOVING A/C IN
 GARAGE AT END OF TEMP OFFICE,02010983

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2002-04-02 Cont ID  
Sent By jwitmer Date 2002-04-02 Time 06:59 Rev Time 1.00
Received By jwitmer Date   Time   Sent To  
Notes
2002-04-02 00:00:00BUILDING PLAN REVIEW
 PERMIT # 01121731-REVISION
 6211 EATON STREET
 CONTINENTAL HOMES
 (954)428-4854 ROBIN
  
 SBC=1997 STANDARD BUILDING CODE
  
 1- THE CONVERSION FROM GARAGE TO SALES
 OFFICE SHALL REQUIRE ADDITIONAL
 PRODUCT APPROVAL FOR THE DOUBLE FRENCH
 DOORS. SINCE THEY ARE GLAZED OPENINGS
 INDICATE ALSO THE HURRICANE PROTECTION
 REQUIRED FORTHESE OPENINGS.
 2)- THE GARAGE ENETRY SHOWS A 6" DROP,
 IF THIS WAS TO BE A GARAGE WOULDN'T IT
 BE A 11/2" DEPRESSION FOR THE GARAGE
 DOOR? THERE MAY BE A CHANGE OF GRADE NOT
 GREATER THAN 1/2" FL HANDICAPPED CODE
 4.3.8. THIS CONDITION ALSOSHALL EXIST
 AT THE FRONT DOOR. REMEMBER RAMPS ARE TO
 LANDINGS AT TOP AND BOTTOM OF RAMP.
 RAMPS GREATER THAN 6" REQUIRES HANDRAILS
 4.8.5.
 3)- 4.5.1 GROUND AND FLOOR SURFACES
 ALONG ACCESSIBLE ROUTES AND IN ACCESS-
 IBLE ROOMS INCLUDING FLOORS, WALKS, AND
 RAMPS, SHALL BE STABLE, FIRM, SLIP
 RESISANT, ADDAAG A-5 A STATIC COEFFIC-
 IENT OF FRICTION OF 0.6 FOR ACCESSIBLE
 ROUTES AND 0.8 FORRAMPS.
 4)- THE POWDER ROOM, INSWING DOOR ACCESS
 CODE 4.22.2 ALL DOORS TO ACCESSIBLE
 TOILET ROOMS SHALL NOT SWING INTO THE
 CLEAR FLOOR SPACE REQUIRED FOR ANY
 FIXTURE.
 5)- STRUCTURAL STRENGTH 4.26.3.(1)
 BENDING STRESS IN A GRAB BAR INDUCED BY
 THE BENDING MOMENT FROM THE APPLICATION
 OF 250 LBF.
 BUILDING PLAN REVIEW
 JIM WITMER
 (651)659-8096 X8412

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2001-12-10 Cont ID  
Sent By lsmith Date 2002-01-31 Time 10:09 Rev Time 0.00
Received By lsmith Date   Time   Sent To  
Notes
2002-01-31 00:00:00PER JW 12/10/01

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2002-05-24 Cont ID  
Sent By kstevens Date 2002-05-25 Time 12:25 Rev Time 0.00
Received By dpalmer Date 2002-05-24 Time 06:17 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2002-04-02 Cont ID  
Sent By btrobaug Date 2002-04-02 Time 08:39 Rev Time 0.00
Received By btrobaug Date 2002-04-02 Time 08:39 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2002-03-12 Cont ID  
Sent By dpalmer Date 2002-03-12 Time 08:49 Rev Time 0.00
Received By dpalmer Date 2002-03-12 Time 08:49 Sent To  
Notes
2002-03-12 00:00:00************ UNSAT *****************
  
 1)NOTE: PLEASE SEE FIRE REVIEW COMMENTS,
 FOR ANY EXIT/EM LIGHTING REQ`MENTS.
  
 2)NOTE: PLEASE CLARIFY WHAT HAPPENED TO
 UPSTAIRS ELECTRICAL?
  
 3)NOTE: PLEASE NOTE MISSING EQUIPMENT
 GROUNDING CONDCUTOR BETWEEN FIRST MEANS
 OF DISCONNECT AND PANEL. SIZE PER
 250-122
  
 4)NOTE: PLEASE CLARIFY IF USE WILL BE
 GOING BACKTO RESIDENTIAL? PLEASE NOTE
 LOAD CALCUALTIONS ARE SHOWN FOR RES AND
 NOT COMMERCIAL USE?
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT8372

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-01-30 Cont ID  
Sent By dpalmer Date 2002-01-30 Time 13:44 Rev Time 0.00
Received By dpalmer Date 2002-01-30 Time 13:44 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2002-06-05 Cont ID  
Sent By mcarsill Date 2002-06-05 Time 10:29 Rev Time 0.00
Received By mcarsill Date 2002-06-05 Time 10:29 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2002-03-21 Cont ID  
Sent By mcarsill Date 2002-03-21 Time 13:32 Rev Time 0.00
Received By mcarsill Date 2002-03-21 Time 13:32 Sent To  
Notes
2002-03-21 00:00:00A) EXIT SIGNS AND EMERGENCY LIGHTS
 ARE REQUIRED SINCE THE SPACE WILL
 FUNCTION AS A BUSINESS OCCUPANY.
 B) WILL OCCUPANCY BE PRESENT ON THE
 SECOND FLOOR.
 C) PORTABLE FIRE EXTINGUISHERS WILL BE
 REQUIRED.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 659-8096,EXT.8497
 835-2910

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2001-10-16 Cont ID  
Sent By lsmith Date 2002-01-31 Time 10:10 Rev Time 0.00
Received By lsmith Date   Time   Sent To  
Notes
2002-01-31 00:00:00PER MEC LS

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2002-05-28 Cont ID  
Sent By pkrauss Date 2002-05-28 Time 16:32 Rev Time 0.35
Received By pkrauss Date 2002-05-28 Time 16:27 Sent To  
Notes
2002-05-28 00:00:00MECHANICAL PERMIT 02010983
  
 REVISION - NOTE STATING A/C TO BE RE-
 MOVED FROM THE GARAGE PRIOR TO FINAL.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-03-12 Cont ID  
Sent By pkrauss Date 2002-03-12 Time 11:55 Rev Time 0.45
Received By pkrauss Date 2002-03-12 Time 11:55 Sent To  
Notes
2002-03-12 00:00:00 
 PROVISO:
  
 PRIOR TO FINAL C.O., SUBMIT REVISION
 INDICATING THE DUCTWORK HAS BEEN
 REMOVED FROM THE GARAGE AREA.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2002-01-31 Cont ID  
Sent By pkrauss Date 2002-01-31 Time 10:38 Rev Time 0.05
Received By pkrauss Date   Time   Sent To  
Notes
2002-01-31 00:00:00APPROVED ON MASTER 01091364

Review Stop P PLUMBING
Rev No 3 Status P Date 2002-05-25 Cont ID  
Sent By kstevens Date 2002-05-25 Time 12:25 Rev Time 0.00
Received By kstevens Date 2002-05-25 Time 12:25 Sent To E
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2002-04-02 Cont ID  
Sent By kstevens Date 2002-04-02 Time 13:49 Rev Time 0.00
Received By kstevens Date 2002-04-02 Time 13:49 Sent To  
Notes
2002-04-02 00:00:00DENIED
 REFERENCE: SPC-94 - FACBC-97
  
 1) SHT 1 BATHROOM DOOR SHALL NOT SWING
 INTO CLEAR FLOOR SPACE OR UNOBSTRUCTED
 TURNING RADIUS. SEC 4.22.2
 2) SHT 1 W/C SHALL BE 1'6" TO CENTER OFF
 WALL NOT 2'2" AS SHOWN.
 3) SHT 1 SHOW DETAIL FOR HDCP FIXTURES
 W/C AND LAV PER SECS 4.16, 4.16.2,
 4.16.3, 4.16.5 AND 4.19, 4.19.2, 4.19.3,
 4.19.4, 4.19.5
 4) SHT 1 TABLE 407 REQUIRES A DRINKING
 FOUNTAIN.
 5) SHT 1 SANT RISER SHOWS A DRY HORIZON-
 TAL VENT. PER SEC 906.2.1 THIS IS NOT
 APPROVED.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-01-31 Cont ID  
Sent By lsmith Date 2002-01-31 Time 10:10 Rev Time 0.00
Received By lsmith Date   Time   Sent To  
Notes
2002-01-31 00:00:00PER KS 10/11/01

Review Stop Z ZONING
Rev No 1 Status P Date 2002-01-29 Cont ID  
Sent By aneil Date 2002-01-29 Time 15:32 Rev Time 1.00
Received By aneil Date   Time   Sent To  
Notes
2002-01-29 00:00:00PASSED PER SHIRLEY 1-29-2002 AN