Plan Review Details - Permit 01121621
Plan Review Stops For Permit 01121621 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2002-01-18 |
|
|
Cont ID |
|
Sent By |
lsmith |
Date |
2002-01-18 |
Time |
09:08 |
Rev Time |
0.50 |
Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2002-01-22 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-01-22 |
Time |
08:57 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2002-01-22 |
Time |
08:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2002-01-10 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-01-10 |
Time |
07:05 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2002-01-10 |
Time |
07:05 |
Sent To |
P |
|
Notes |
2002-01-10 00:00:00 | **************** UNSAT ************** | | | | 1)NOTE: PLEASE SEE NOTE #1 FROM FIRST | | REVIEW WAS NOT ADDRESSED. PLEASE NOTE | | 8 1/2X11`S SUBMITTED FOR LOAD CALCS AND | | SERIVCE SIZE CONTAIN TITLE BLOCKS FOR | | AN ARCH/ENG OF RECORD. PLEASE NOTE, | | FLORIDA STATUES/ FLORIDA ADMINISTRATIVE | | CODE: MUST BE SIGNED, DATED AND SEALED | | PER 481.221/7471.025 | | | | PLEASE NOTE THAT NOTE #2 WAS ADDRESSED | | AND OS OK. PLEASE SUBMIT THE OTHE | | DOCUMENTS WITH CORRECTIONS MADE. | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2002-01-02 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-01-02 |
Time |
16:11 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2002-01-02 |
Time |
16:11 |
Sent To |
|
|
Notes |
2002-01-02 00:00:00 | ************** UNSAT ************** | | | | 1)NOTE: PLEASE NOTE THAT ANY DOCUMENTS/ | | PLANS SUBMITTED THAT CONTAIN A TITLE | | BLOCK FROM AN ARCH/ ENGINEER, MUST | | BE SIGNED, DATED AND SEALED BY THE | | ARCH/OR ENGINEER OF RECORD. 471.025 AND | | 481.221 | | | | 2)NOTE: PLEASE ALSO NOTE THAT THERE IS | | NOTHING ON THE ELECTRICAL WIRING DIAGRAM | | SHOWING ANY HEAT PUMP,CONDUIT/OR WIRE | | SIZES? | | PLEASE SHOW. | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2002-01-12 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-01-10 |
Time |
07:23 |
Rev Time |
0.25 |
Received By |
jleech |
Date |
2002-01-12 |
Time |
13:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2001-12-29 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2001-12-29 |
Time |
07:15 |
Rev Time |
0.33 |
Received By |
jleech |
Date |
2001-12-29 |
Time |
07:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2002-01-22 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-01-22 |
Time |
09:09 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2002-01-22 |
Time |
09:09 |
Sent To |
|
|
Notes |
2002-01-22 00:00:00 | PER SG. |
|
|
|
Account Summary | Usage Policy | Privacy Policy