Plan Review Details - Permit 01121466
Plan Review Stops For Permit 01121466
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2002-01-24 Cont ID  
Sent By pkrauss Date 2002-01-15 Time 08:59 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
2002-01-24 00:00:00PROVISO:
 CONTRACTOR TO SUBMIT PLANS TO PALM
 BEACH COUNTY FOR ASSESSMENT OF COUNTY
 IMPACT FEES.JW

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2002-02-13 Cont ID  
Sent By dpalmer Date 2002-02-13 Time 16:09 Rev Time 0.00
Received By dpalmer Date 2002-02-13 Time 16:09 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-02-13 Cont ID  
Sent By dpalmer Date 2002-02-13 Time 16:09 Rev Time 0.00
Received By dpalmer Date 2002-02-13 Time 10:42 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2002-01-15 Cont ID  
Sent By dpalmer Date 2002-01-15 Time 06:44 Rev Time 0.00
Received By dpalmer Date 2002-01-15 Time 06:44 Sent To M
Notes
2002-01-15 00:00:00******************* UNSAT **************
  
 1)NOTE: PLEASE SUBMIT LOAD CALCULATIONS
 PER 220-3-C-1 FOR MORETHAN 500SQ FT.
 PLEASE NOTE THAT A NEW ELECTRICAL PANEL
 IS SHOWN IN NEW ADDITION, BUT NO RISER
 DIAGRAM WAS SUBMITTED FOR REVIEW.
 PLEASE SUBMIT A RISER DIAGRAM SHOWING
 WHERE/HOW THIS PANEL IS BEING FED.
 WIRE SIZES/CONDUIT ECT.
  
 2) NOTE: PLEASE LIST THE REQ`D BATH(S)
 CIRCUIT(S) PER 210-11-C-3.
 MUST BE 20A AND #12AWG.
 PLEASE SUBMIT A PANEL SCHEDULE SHOWING
 EXSITING? NEW? CIRCUITS, REQ`D.
  
 3)NOTE: PLEASE NOTE THAT MORETHAN 50% OF
 THE ELECTRICAL IS BEING DONE, NOTE SD`S
 WILL BE REQ`D INSIDE AND OUTSIDE ANY
 EXISTING BEDROOMS. PLEASE SHOW
 PLEASE NOTE SD REQ`D IN CABANA, THIS
 ROOM HAS CLOSET/STORAGE AND IS
 CONSIDERED AN ADAPTABLE BEDROOM. NFPA-72
 2-1.1.1
  
 4)NOTE: PLEASE NOTE THAT IF ANY NEW
 ELECTRICAL SERVICE IS GOING TO BE
 SUBMITTED FOR REVIEW, PLEASE SUBMIT THE
 AIC RATINGS FOR ANY NEW SERVICE. 110-9
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW, IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2002-01-15 Cont ID  
Sent By dpalmer Date 2002-01-15 Time 06:55 Rev Time 0.40
Received By pkrauss Date 2002-01-15 Time 07:12 Sent To B
Notes
2002-01-15 00:00:00 
 MECHANICAL PERMIT 02010736
 PROVISO ON PLAN

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-01-12 Cont ID  
Sent By jleech Date 2002-01-12 Time 13:41 Rev Time 0.33
Received By jleech Date 2002-01-12 Time 13:41 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2002-01-09 Cont ID  
Sent By sgraham Date 2002-01-09 Time 16:39 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2002-01-02 Cont ID  
Sent By sgraham Date 2002-01-02 Time 16:50 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***