Plan Review Details - Permit 01121251
Plan Review Stops For Permit 01121251
Review Stop E ELECTRICAL
Rev No 4 Status P Date 2002-09-20 Cont ID  
Sent By btrobaug Date 2002-09-20 Time 13:51 Rev Time 0.50
Received By btrobaug Date 2002-09-20 Time 13:43 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2002-05-01 Cont ID  
Sent By btrobaug Date 2002-05-01 Time 11:58 Rev Time 0.00
Received By btrobaug Date 2002-05-01 Time 11:52 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-04-08 Cont ID  
Sent By btrobaug Date 2002-03-22 Time 11:51 Rev Time 0.00
Received By btrobaug Date 2002-03-22 Time 09:22 Sent To M
Notes
2002-03-22 00:00:00 
 PLEASE PROVIDE A CALCULATION INDICATING
 THE ADDITIONAL LOADS PER 220-31.ALSO
 NOTE ARTICLE 220-12(B) FOR TRACK
 LIGHTING.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL;
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 561/659-8096 EXT.8392

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-01-16 Cont ID  
Sent By btrobaug Date 2002-01-16 Time 16:31 Rev Time 0.33
Received By btrobaug Date 2002-01-16 Time 16:06 Sent To R
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2002-06-03 Cont ID  
Sent By pkrauss Date 2002-06-03 Time 07:45 Rev Time 0.30
Received By pkrauss Date 2002-06-03 Time 07:24 Sent To  
Notes
2002-06-03 00:00:00MECH PERMIT 02051089

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-03-25 Cont ID  
Sent By btrobaug Date 2002-05-01 Time 14:16 Rev Time 0.33
Received By hmoser Date 2002-03-25 Time 19:33 Sent To  
Notes
2002-03-25 00:00:00REVISON OK A/C FOR SALES OFFICE
 3/25/02 H.M.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2002-01-09 Cont ID  
Sent By btrobaug Date 2002-03-22 Time 12:07 Rev Time 0.33
Received By hmoser Date 2002-01-09 Time 19:18 Sent To  
Notes
2002-01-09 00:00:00NO MECHANICAL PERMIT NUMBER ON THIS
 APPLICATION 1/9/02 H.M.

Review Stop P PLUMBING
Rev No 3 Status P Date 2002-09-04 Cont ID  
Sent By kstevens Date 2002-09-04 Time 13:45 Rev Time 0.00
Received By kstevens Date 2002-09-04 Time 13:45 Sent To  
Notes
2002-09-04 00:00:00REVISION OK - SANT. RISER DIAGRAM

Review Stop P PLUMBING
Rev No 2 Status F Date 2002-08-29 Cont ID  
Sent By kstevens Date 2002-08-29 Time 07:51 Rev Time 0.00
Received By kstevens Date 2002-08-29 Time 07:51 Sent To  
Notes
2002-08-29 00:00:00DENIED
 REFERENCE: SPC-94
  
 1) ALL REVISIONS TO A SIGNED AND SEALED
 SET OF PLANS SHALL BE SIGNED AND SEALED
 BY THE ARCHITECT OF RECORD.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-01-05 Cont ID  
Sent By jleech Date 2002-01-05 Time 11:19 Rev Time 0.33
Received By jleech Date 2002-01-05 Time 11:19 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 6 Status P Date 2002-05-24 Cont ID  
Sent By jgomez Date 2002-05-24 Time 11:30 Rev Time 1.50
Received By jgomez Date 2002-05-24 Time 11:30 Sent To  
Notes
2002-05-24 00:00:00TRUSS DRAWINGS, REVISION AND PRODUCT
 APPROVALS REVIEW.

Review Stop R ROOF PLAN REVIEW
Rev No 5 Status P Date 2002-04-30 Cont ID  
Sent By jgomez Date 2002-04-30 Time 16:50 Rev Time 1.50
Received By jgomez Date 2002-04-30 Time 16:50 Sent To  
Notes
2002-04-30 00:00:00APPROVED WITH PROVISO:
 1-NEED LETTER FROM ONE OF THE PRINCIPALS
 OF THE COMPANY (NOTARIZED OR WITH THE
 CORPORATE SEAL) ADDRESSED TO THE
 BUILDING OFFICIAL, NEIL MELICK, WITH
 YOUR REQUEST INDICATING THE LENGTH OF
 TIME THE TEMPORARY SALES OFFICE WILL
 BE OPERATING.
 NOTE: A CONDITIONAL CERTIFICATE OF
 OCCUPANCY WILL BE REQUIRED BEFORE THE
 TEMPORARY SALES OFFICE CAN BE OPENED
 TO THE PUBLIC. THE FINAL C.O. FOR THE
 RESIDENCE WILL BE ISSUED WHEN THE
 SALES OFFICE GETS CONVERTED BACK TO
 GARAGE.
 2-AWNING TO BE DONE UNDER A SEPARATE
 PERMIT.
 3-STORM SHUTTERS UNDER A SEPARATE PERMIT

Review Stop R ROOF PLAN REVIEW
Rev No 4 Status F Date 2002-04-10 Cont ID  
Sent By jgomez Date 2002-04-10 Time 15:06 Rev Time 2.00
Received By jgomez Date 2002-04-10 Time 15:06 Sent To  
Notes
2002-04-10 00:00:00TRUSS DRAWINGS CHECKLIST:
 1-ARCHITECT TO REVIEW ALL TRUSS DRAWINGS
 AFTER CORRECTIONS ARE DONE.
 2-TRUSS LAYOUT: A)ENGINEER TO PROVIDE
 HIS INFORMATION AND SIGN, SEAL AND DATE
 AS REQUIRED BY CHAPTER 471 FL. STATUTES
 WHEN SUBMITTING DWGS FOR PUBLIC RECORDS
 B)REVISE LOADING CRITERIA. SEE THE
 STRUCTURAL DRAWINGS.
 C)FIN. ROOFIS CEMENT TILE NOT SHINGLES
 D)SPECIFY CODE USED.
 3-ENGINEERED TRUSSES:
 A)REVISE LOADING SEE STRUCTURAL DRAWINGS
 B)CLEARLY SPECIFY CODE USED. SBC 1997
 FOR 110MPH OR ASCE 7-95 FOR 140MPH.
 NOT SBCCI 1999.
 C)TRUSS ENGINEER TO PROVIDE DRAWINGS W/
 ORIGINAL SIGNATURE. CHAPTER 471 FL. ST.
 4-ARCHITECT'S ANCHOR SCHEDULE:
 A)THERE IS NOT RT24 ANCHOR ON USP
 CATALOGUE. IS THIS A CUSTOM MADE
 CONNECTOR?. PROVIDE SPECIFICATIONS AND
 ENGINEERED CALCULATIONS.
 B)PROVIDE CONNECTORS TO RESIST UPLIFT
 LOADS CALCULATED ON THE ENGINEERED
 TRUSSES H1A, H1B, H2A, FG4 AND ALL
 OTHERS WHERE UPLIFT LOADS EXCEEDS THE
 CONNECTOR CAPACITY. SEE ENGINEER' DWGS
 D)SPECIFY CONNECTORS FOR TRUSSES HG3A
 AND FG4. SEE ENGINEERED TRUSSES.

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status F Date 2002-03-26 Cont ID  
Sent By jgomez Date 2002-03-26 Time 17:44 Rev Time 1.00
Received By jgomez Date 2002-03-26 Time 17:44 Sent To  
Notes
2002-03-26 00:00:00REVISION CHECKLIST:
 1-CHANGE OF USE FROM GARAGE TO SALES
 OFFICE NEEDS TO COMPLY WITH FLORIDA
 ACCESSIBILITY CODE FOR BUILDING CONST.
 1997 ED. PROVIDE ACCESSIBLE ROUTE,
 ACCESSIBLE RESTROOM AND ACCESSIBLE
 PARKING.
 2-PROVIDE COMPLETE SPECIFICATIONS AND
 INSTALLATION DETAILS FOR AWNNG OR
 APPLY FOR A SEPARATE PERMIT.
 3-CLEARLY SPECIFY ON PLANS SAFETY GLASS
 REQUIRED BY SECTION 2405.2 SBC 1997.
 4-PRODUCT APPROVAL SUBMITTED FOR ENTRY
 DOORS IS FOR OUTSWING DOOR. DRAWINGS
 SHOW INSWING DOOR. REVISE AS REQUIRED.
 5-VALUE FOR BUILDING SALES OFFICE NEEDS
 TO BE DECLARED TO APPLY PROPER FEES.
 6-PROVIDE COMPLETE INFORMATION FOR STORM
 SHUTTERS OR APPLY FOR SEPARATE PERMIT.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2002-03-06 Cont ID  
Sent By jgomez Date 2002-03-06 Time 12:08 Rev Time 3.50
Received By jgomez Date 2002-03-06 Time 12:08 Sent To  
Notes
2002-03-06 00:00:00APPROVED WITH PROVISO:
 1-STORM SHUTTERS: SINCE INFORMATION IS
 NOT CORRECT AND INCOMPLETE, THEN APPLY
 FOR STORM SHUTTERS UNDER A SEPARATE
 PERMIT TO EXPEDITE BUILDING PERMIT.
 2-SPECIFY FASTENERS FOR GUARDRAILS THAT
 SATISFY THE DESIGN REQUIREMENTS OF
 SEC. 1608.2.2 SBC 1997. DETAIL GIVEN
 AT BOTTOM OF PAGE 4 OF 7 IS ONLY FOR
 THE RAILING PART, NOT THE GUARDRAIL.
 3-PROVIDE PRODUCT APPROVAL FOR:
 A)SINGLE HUNG WINDOWS (NEED ACTUAL
 PRODUCT APPROVAL, NOT TESTING RESULTS)
 B)DOUBLE ENTRY DOORS (THE ONE SUBMITTED
 IS FOR SINGLE DOORS ONLY).
 C)SLIDING GLASS DOORS. SEE SIZES AND
 DESIGN PRESSURES SHOWN ON THE PLANS.
 MAKE SURE ALL DRAWINGS ARE LEGIBLE.
 D)ARCHED WINDOWS (FIXED WINDOW PRODUCT
 APPROVAL IS FOR RECTANGULAR WINDOWS
 ONLY. SEE PRODUCT APPROVAL DRAWINGS
 FOR APPROVED SIZE AND SHAPES.
 E)WINDOW MULLIONS.
 F)AWNING WINDOW. (DWGS ARE NOT LEGIBLE).
  
 4-SEE COMMENTS ON PLANS

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2002-01-29 Cont ID  
Sent By btrobaug Date 2002-01-16 Time 16:31 Rev Time 4.50
Received By jgomez Date 2002-01-29 Time 17:53 Sent To  
Notes
2002-01-29 00:00:00CHECKLIST:
 1-NEED RECORDED NOTICE OF COMMENCEMENT.
 2-PAY IMPACT FEES AND BRING PAID RECEIPT
 3-CLARIFY LOCATION OF SHEARWALL SEGMENTS
 AND DIMENSIONS. SEE ELEVATIONS AND
 2ND. FLOOR FRAMING PLAN.
 -CLARIFY FASTENING AT ENDS OF SHEARWALL
 -CLARIFY WHY THERE ARE NOT SHEARWALLS
 AT FRONT ELEVATION?
 -HOW ARE CORNERS AT 2ND FL. REINFORCED?
 4-FIRST FLOOR BATH TO HAVE DOOR THAT
 PROVIDES 29" MIN. CLEAR OPENING. SEC.
 11 OF FLORIDA ACCESSIBILITY CODE, 1997
 5-PROVIDE ATTIC ACCESS AT LANAI ROOF.
 SEC. 2309.6 SBC 1997.
 6-SHOW RAILINGS AT STAIRS. SEC. 1007.5
 -SPECIFY FASTENERS FOR GUARDRAILS AND
 HANDRAILS THAT SATISFY THE DESIGN
 REQUIREMENTS OF SEC. 1608.2 SBC 1997.
 7-SPECIFY BEAM ABOVE BREAKFAST AREA AND
 END CONNECTORS. SEC. 104.2.2 CITY
 AMENDMENTS AND SEC. 1606 SBC 1997.
 8-COMPLETE STEEL COLUMN DETAIL. SPECIFY
 TOP AND BOTTOM ATTACHMENTS. SECTION
 104.2.2 CITY AMENDMENTS TO SBC 1997 &
 SEC. 1606 SBC 1997.
 9-PROVIDE STRUCTURAL BUCK DETAIL FOR
 EXTERIOR SWING DOORS. SEC. 104.2.2
 CITY AMENDMENTS TO SBC 1997.
 10-SOIL TEST REPORT TO HAVE ENGINEER'S
 ORIGINAL SIGNATURE (NOT RUBBER STAMP)
 AS REQUIRED BY CHAPTER 471 FL STATUTES
 11-LEFT SIDE EXTERIOR ELEVATION DOESN'T
 MATCH FLOOR PLANS. SEE WINDOWS AND
 DOORS NOT SHOWN.
 -CLARIFY PITCH OF ROOF. SEE ELEVATIONS.
 12-PROVIDE PRODUCT APPROVAL FOR:
 A)ENTRY DOORS.
 B)HORIZONTAL ROLLING WINDOWS (DRAWINGS
 ARE NOT LEGIBLE).
 C)SINGLE HUNG WINDOWS.
 D)SLIDING GLASS DOORS(DWGS NOT LEGIBLE).
 E)ARCHED WINDOWS. SEE SIZES ON PLANS.
 F)WINDOW MULLIONS.
 G)AWNING WINDOWS.
 H)ROOF TILE.
  
 13-SPECIFY THE DESIGN PRESSURES THAT
 WERE CALCULATED AT EACH EXT. OPENING.
 SEC. 1606 SBC 1997.
 14-REVISE THE OWNER INFORMATION IN THE
 ENERGY CALCULATIONS AND COMPLETE ALL
 INFORMATION ON TOP OF FORM.
 15-SPECIFY FASTENINGS FOR RAILINGS AND
 GUARDRAILS TO COMPLY WITH SECTION
 1608.2 SBC 1997.
 -SHOW RAILINGS ON PLANS. SECTION
 1007.5 SBC 1997.
 16-SPECIFY CEILING INSTALLATION AT ENTRY
 AND REAR PORCHES. SEE ASTM C926 AND
 ASTM C1063 FOR PROPER SPECIFICATIONS.
 SEC. 2504.2SBC 1997.
 17-SEE COMMENTS ON PLANS, INCLUDING
 COMMENTS BY THE OTHER TRADES.
 -PLEASE BRING BACK REVIEWED SET AFTER
 CORRECTIONS ARE DONE TO THE ORIGINAL
 DRAWINGS IN ORDER TO EXPEDITE THE
 REVIEW PROCESS.
 18-STORM PANELS:
 A)PROVIDE COMPLETE INSTALLATION SCHEDULE
 AS PER CITY SAMPLE ATTACHED.
 B)PROVIDE KEY PLAN THAT MATCHES ACTUAL
 ARCHITECTURAL PLANS.
 C)STORM SHUTTERS PRODUCT APPROVAL IS
 GOOD FOR ONE PERMIT ONLY. SEE NOTE ON
 STORM SHUTTERS APPROVED DRAWINGS.
 D)CLEARLY INDICATE ON STORM SHUTTER DWGS
 THE SPECIFIC MOUNTING CONDITIONS AND
 ANCHOR TYPE AND SPACING TO BE USED
 ACCORDING TO THE MEAN ROOF HEIGHT,
 DESIGN PRESSURES, PANEL SPAN, EDGE
 DISTANCE AND STRUCTURE TO BE ATTACHED
 TO (WOOD OR CONCRETE BLOCK).

Review Stop Z ZONING
Rev No 3 Status P Date 2002-05-02 Cont ID  
Sent By sgraham Date 2002-05-02 Time 09:39 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
2002-05-02 00:00:00MUST MAINTAIN THE PARKING LOT & LAND-
 SCAPING UNTIL THE SALE OFFICE IS REMOVED

Review Stop Z ZONING
Rev No 2 Status   Date   Cont ID  
Sent By btrobaug Date 2002-05-01 Time 12:01 Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
2002-03-27 00:00:00NEED PARKING AREA WITH H/C

Review Stop Z ZONING
Rev No 1 Status P Date 2002-01-03 Cont ID  
Sent By sgraham Date 2002-01-03 Time 11:00 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***