Plan Review Details - Permit 01121248
Plan Review Stops For Permit 01121248
Review Stop E ELECTRICAL
Rev No 3 Status P Date 2002-09-20 Cont ID  
Sent By btrobaug Date 2002-09-20 Time 13:39 Rev Time 0.50
Received By btrobaug Date 2002-09-20 Time 13:26 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-06-03 Cont ID  
Sent By pkrauss Date 2002-06-06 Time 15:25 Rev Time 0.00
Received By btrobaug Date 2002-06-03 Time 07:57 Sent To FIRE
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-01-17 Cont ID  
Sent By btrobaug Date 2002-01-17 Time 12:39 Rev Time 0.50
Received By btrobaug Date 2002-01-17 Time 12:39 Sent To R
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2002-06-05 Cont ID  
Sent By btrobaug Date 2002-06-03 Time 09:02 Rev Time 0.00
Received By mcarsill Date 2002-06-05 Time 14:26 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-06-06 Cont ID  
Sent By pkrauss Date 2002-06-06 Time 15:25 Rev Time 0.30
Received By pkrauss Date 2002-06-03 Time 07:46 Sent To R
Notes
2002-06-06 00:00:00MECHANICAL PERMIT 02051087

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2002-01-15 Cont ID  
Sent By hmoser Date 2002-01-15 Time 16:58 Rev Time 0.50
Received By hmoser Date 2002-01-15 Time 16:58 Sent To  
Notes
2002-01-15 00:00:00NO PERMIT NUMBER ON THIS APPLICATION
 01/15/02H.M.

Review Stop P PLUMBING
Rev No 3 Status P Date 2002-09-04 Cont ID  
Sent By kstevens Date 2002-09-04 Time 13:43 Rev Time 0.00
Received By kstevens Date 2002-09-04 Time 13:43 Sent To  
Notes
2002-09-04 00:00:00REVISION OK - REVERSE SANT. RISER DIAG.

Review Stop P PLUMBING
Rev No 2 Status F Date 2002-08-28 Cont ID  
Sent By kstevens Date 2002-08-28 Time 18:39 Rev Time 0.00
Received By kstevens Date 2002-08-28 Time 18:39 Sent To  
Notes
2002-08-28 00:00:00DENIED
 REFERENCE: SPC-94
  
 1) SANITARY RISER DIAGRAM DOES NOT RE-
 FLECT THE FLOOR PLAN.
 2) ALL REVISIONS TO A SIGNED AND SEALED
 SET OF PLANS SHALL BE SIGNED AND SEALED
 BY THE ARCHITECT OF RECORD.
 3) PLEASE SUBMIT A SANITARY RISER DIA-
 GRAM THAT REFLECTS THE FLOOR PLAN AND
 HOW THE PIPING WAS INSTALLED.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-01-05 Cont ID  
Sent By jleech Date 2002-01-05 Time 10:33 Rev Time 0.33
Received By jleech Date 2002-01-05 Time 10:33 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 8 Status F Date 2002-08-08 Cont ID  
Sent By jgomez Date 2002-08-08 Time 18:47 Rev Time 0.00
Received By jgomez Date 2002-08-08 Time 18:47 Sent To  
Notes
2002-08-08 00:00:00CHECKLIST:
 PROVIDE SPECIFICATIONS FOR SILICONE TO
 BE USED AT BUTT AREA.

Review Stop R ROOF PLAN REVIEW
Rev No 7 Status F Date 2002-06-20 Cont ID  
Sent By jgomez Date 2002-06-20 Time 09:37 Rev Time 0.50
Received By jgomez Date 2002-06-20 Time 09:37 Sent To  
Notes
2002-06-20 00:00:00BUTT GLAZING PRODUCT APPROVAL CHECKLIST:
  
 1-PROVIDE COMPLETE ENGINEERING ANALYSIS,
 CALCULATIONS, DRAWINGS & CALCULATIONS
 FOR COMPLETE ASSEMBLY AS SHOWN ON THE
 PLANS. FRAGMENTED INFORMATION FROM
 DIFFERENT SOURCES AS SUBMITTED IS NOT
 ACCEPTABLE. INCLUDE ALL SPECIFIC
 COMPONENTS THAT WILL PUT THIS ASSEMBLY
 TOGETHER IN THE HOUSE.
 SEE SECTION 2406.2 FBC 2001 FOR ALL
 INFORMATION REQUIRED.

Review Stop R ROOF PLAN REVIEW
Rev No 6 Status F Date 2002-06-08 Cont ID  
Sent By jgomez Date 2002-06-08 Time 18:33 Rev Time 0.50
Received By jgomez Date 2002-06-08 Time 18:33 Sent To  
Notes
2002-06-08 00:00:00GARAGE CONVERSION TO SALES OFFICE:
  
 1-NEED LETTER FOM ONE OF THE PRINCIPALS
 OF THE COMPANY (NOTARIZED OR WITH THE
 CORPORATE SEAL) ADDRESED TO THE
 BUILDING OFFICIAL, NEIL MELICK, WITH
 YOUR REQUEST INDICATING THE LENGHT FOR
 TEMPORARY SALES OFFICE. CHECK WITH
 ZONING FOR MAXIMUM LENGHT.
 NOTE: A CONDITIONAL CERTIFICATE OF
 OCCUPANCY WILL BE REQUIRED BEFORE THE
 TEMPORARY SALES OFFICE CAN BE OPENED
 TO THE PUBLIC. THE FINAL C.O WILL BE
 ISSUED WHEN CONVERTING OFFICE BACK TO
 GARAGE.
 2-PROVIDE PLANS SHOWING ACCESSIBLE ROUTE
 AND PARKING FOR ZONING REVIEW.

Review Stop R ROOF PLAN REVIEW
Rev No 5 Status F Date 2002-05-29 Cont ID  
Sent By pkrauss Date 2002-06-06 Time 15:25 Rev Time 1.00
Received By jgomez Date 2002-05-29 Time 15:11 Sent To  
Notes
2002-05-28 00:00:00TRUSS DRAWINGS AND SUBMITTAL PACKAGE
 CHECKLIST:
  
 1-TRUSS DRAWINGS ARE MISSING THE
 ENGINEERED FLOOR TRUSSES. THEY ARE NOT
 EVEN IN THE INDEX SHEET.
 2-TRUSS ENGINEER FAILURE TO PROVIDE ALL
 HIS INFORMATION ON THE TRUSS LAYOUT
 AS REQUIRED BY CHAPTER 471 FLORIDA
 STATUTES AND AS REQUESTED ON PREVIOUS
 CHECKLIST.
 3-BUTT GLAZING ASSEMBLY TO BE DESIGNED
 AS REQUIRED BY SECTION 2406.2 FBC
 2001. READ THAT SECTION AND SUBMIT
 APPROPRIATE PACKAGE.
 4-SLIDING GLASS DOORS PRODUCT APPROVAL
 IS NOT GOOD. SEE SIZE AND DESIGN
 PRESSURES SPECIFIED ON ARCHITECT'S
 PLANS.
 5-PROVIDE PRODUCT APPROVAL FOR POCKET
 SLIDING GLASS DOORS ASSEMBLY. SEE
 ARCHITECT'S PLANS FOR SIZE AND DESIGN
 PRESSURES.
 6-PROVIDE FRAMING DETAILS AND SPECS FOR
 POCKET SLIDING GLASS DOORS.
  
  
 NOTES:
  
 1-STAMPED DRAWINGS AND PRODUCT APPROVALS
 ARE ALREADY APPROVED.
 2-COORDINATE WITH BUILDING INSPECTOR
 REGARDING THE TRUSS DRAWINGS PACKAGE.

Review Stop R ROOF PLAN REVIEW
Rev No 4 Status F Date 2002-05-28 Cont ID  
Sent By jgomez Date 2002-05-28 Time 17:57 Rev Time 0.25
Received By jgomez Date 2002-05-28 Time 17:57 Sent To  
Notes
2002-05-28 00:00:00CHECKLIST FOR BUTT GLAZING PRODUCT
 APPROVAL:
 1-SITE SPECIFIC BUTT GLAZING ASSEMBLY TO
 BE DESIGNED AS REQUIRED BY SECTION
 2406.2 SBC 1997. PROVIDE ALL
 INFORMATION AS REQUIRED ON SUCH SECT'N

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status F Date 2002-04-18 Cont ID  
Sent By jgomez Date 2002-04-18 Time 09:31 Rev Time 1.00
Received By jgomez Date 2002-04-18 Time 09:31 Sent To  
Notes
2002-04-18 00:00:00TRUSS DRAWINGS CHECKLIST:
 1-ARCHITECT TO REVIEW ALL TRUSS DRAWINGS
 AFTER CORRECTIONS ARE DONE.
 2-TRUSS LAYOUT:
 A)ENGINEER TO PROVIDE HIS INFORMATION AS
 REQ'D BY CHAPTER 471 FLORIDA STATUTES.
 B)REVISE LOADING CRITERIA. SEE THE
 STRUCTURAL DRAWINGS.
 C)SPECIFY CODE AND YEAR USED.
 3-ENGINEERED TRUSSES:
 A)REVISE LOADING CRITERIA FOR FLOOR
 TRUSSES AND ROOF TRUSSES. SEE THE
 STRUCTURAL DRAWINGS.
 B)CLEARLY SPECIFY CODE USED & YEAR.
 SBC 1999 IS NOT THE CODE ADOPTED BY
 THE CITY OF WEST PALM BEACH.
 C)TRUSS ENGINEER TO PROVIDE DRAWINGS W/
 ORIGINAL SIGNATURE. CHAPTER 471 FL. ST
 4-ARCHITECT'S ANCHOR SCHEDULE:
 A)THERE IS NOT RT24T CONNECTOR ON USP
 CATALOGUE. IS THIS A CUSTOM MADE
 CONNECTOR?. PROVIDE SPECIFICATIONS AND
 ENGINEERED CALCULATIONS.
 B)SAME COMMENTS AS ABOVE FOR CONNECTOR
 HTA48.
 C)CONNECTOR #9 DOESN'T RESIST THE UPLIFT
 LOADS CALCULATED ON THE ENGINEERED
 ROOF TRUSSES. REVISE AS REQUIRED. SEE
 ENGINEERED TRUSSES.
 5-PROVIDE COMPLETE DETAILS AND SPECS FOR
 INTERMEDIATE COLUMNS TO SUPPORT TRUSS
 H1A. SPECIFY ALL CONNECTORS, TOP AND
 BOTTOM AND FOOTING SIZE & REINFORCING.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2002-03-07 Cont ID  
Sent By jgomez Date 2002-03-07 Time 10:46 Rev Time 3.50
Received By jgomez Date 2002-03-07 Time 10:45 Sent To  
Notes
2002-03-07 00:00:00APPROVED WITH PROVISO:
 1-PROVIDE CORRECT INFORMATION FOR STORM
 PANELS UNDER A SEPARATE PERMIT.
 CHECK ANCHOR TYPE AND SPACING FOR
 MASONRY NOT CONCRETE. SEE LIMITATIONS
 ON PRODUCT APPROVAL.
 2-SPECIFY ALL FASTENERS FOR GUARDRAILS
 TO SATISFY DESIGN REQUIREMENTS OF SEC
 1608.2.2 SBC 1997.
 3-PROVIDE PRODUCT APPROVAL FOR:
 A)SINGLE HUNG WINDOWS (NEED ACTUAL
 PRODUCT APPROVAL, NOT JUST TEST RESULT
 B)DOUBLE ENTRY DOORS AS SHOWN ON PLANS.
 C)SLIDING GLASS DOORS. SEE SIZES AND
 DESIGN PRESSURES SHOWN ON PLANS.
 D)ARCHED WINDOWS. PRODUCT APPROVAL SUB-
 MITTED IS FOR RECTANGULAR WINDOWS ONLY
 SEE APPROVED DRAWINGS.
 E)OVAL WINDOW. SAME COMMENT AS ABOVE.
 F)WINDOW MULLIONS.
 G)AWNING WINDOWS. DWGS ARE NOT LEGIBLE.
 H)SLIDING GLASS DOORS WITH POCKET
 ASSEMBLY AS SHOWN ON PLANS.
 I)COMPLETE BUTT GLAZING ASSEMBLY AS
 SHOWN ON PLANS. IF USING SITE SPECIFIC
 FORM, THEN IT HAS TO BE SIGNED, SEALED
 AND DATED BY THE MANUFACTURER'S ENG'R
 AND BY THE ARCHITECT OF RECORD. SEE
 ATTACHED SAMPLE.
  
 4-SHEARWALLS LETTER BY ENGINEER NEEDS:
 A)ORIGINAL SIGNATURE AND DATE.
 B)ENGINEER NAME AND LICENSE #.
 ALL THIS INFORMATION IS REQUIRED BY
 CHAPTER 471 OF FLORIDA STATUTES WHEN
 SUBMITTING DOCUMENTS FOR PUBLIC
 RECORDS.
 C)PROVIDE CORRECT ADDRESS FOR THE CITY
 OF WEST PALM BEACH BUILDING DEPT.
  
 5-SEE COMMENTS ON PLANS.
 6-REVISE AREA TABULATIONS. SEE TOTAL.
 7-SPECIFY ON DRAWINGS GLASS AREAS TO
 HAVE SAFETY GLASS. SEE PLANS AND SEC.
 2405.2 SBC 1997.
 8-PROVIDE COMPLETE FRAMING DETAIL/SPECS
 FOR SLIDING GLASS DOORS WITH POCKET
 BY FAMILY AREA. SEC. 104.2.2 CITY
 AMENDMENTS AND SEC. 1606 SBC 1997.
 9-SPECIFY ALL FASTENERS FOR GUARDRAIL
 CONSTRUCTION. SEC. 1608.2.2 SBC 1997
 10-SEE GARAGE DOOR PRODUCT APPROVAL FOR
 STRUCTURAL BUCK INSTALLATION RECOMMEN-
 DATIONS.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2002-01-26 Cont ID  
Sent By btrobaug Date 2002-01-17 Time 12:39 Rev Time 4.50
Received By jgomez Date 2002-01-26 Time 16:57 Sent To  
Notes
2002-01-26 00:00:00CHECKLIST:
 1-NEED RECORDED NOTICE OF COMMENCEMENT.
 2-BRING COPY OF PAID IMPACT FEES RECEIPT
 3-CLARIFY SHEARWALLS:
 A)WHY THERE ARE TWO SHEARWALL SEGMENTS
 SHOWN ON RIGHT ELEVATION ONLY. WHAT
 ABOUT SHEARWALLS ON OTHER ELEVATIONS?
 B)HOW ARE CORNERS AT 2ND FL. REINFORCED?
 4-SPECIFY NUMBER OF RIDGE VENTS ACCORD'G
 TO CALCULATIONS DONE TO DETERMINE THE
 VENTILATION REQUIRED BY SEC. 2309.7
 SBC 1997. THIS IS PART OF THE DESIGN
 SPECIFICATIONS.
 5-SPECIFY THE DESIGN PRESSURES THAT WERE
 CALCULATED AT EACH EXTERIOR OPENINGS
 AS REQUIRED BY SEC. 1606 SBC 1997.
 6-AIR CONDITIONED SQUARE FOOTAGE IS
 INCORRECT:
 A)REVISE CALCULATIONS ON SHEET 2 OF 9.
 B)GO TO PBC AND REVISE SQUARE FOOTAGE
 FOR IMPACT FEES PURPOSE AS WELL.
 C)CONSTRUCTION VALUE WILL BE ADJUSTED
 WHEN PROVIDING CORRECT SQUARE FOOTAGE.
 7-SPECIFY/INDICATE ON PLANS WINDOWS TO
 HAVE SAFETY GLASS. SEC. 2305.2 SBC/97.
 8-PROVIDE COMPLETE FRAMING DETAIL/SPECS
 FOR SLIDING GLASS DOORS WITH POCKET BY
 FAMILY AREA. SEC. 104.2.2 CITY AMENDM.
 9-PROVIDE ATTIC ACCESS AT FIRST FLOOR BY
 BEDROOM #2 REAR ROOF. SEC. 2309.6 SBC
 -PROVIDE ATTIC ACCESS AT 2ND FL. ROOF.
 10-PROVIDE EGRESS WINDOW FOR "GAME ROOM"
 SEC. 1005.4 SBC 1997. FOR SAFETY
 REASONS THIS ROOM IS CONSIDERED FOR
 SLEEPING AS WELL.
 11-SPECIFY FASTENINGS FOR RAILINGS. SEC.
 1608.2 SBC 1997.
 12-REVISE RATIO OF STAIRS TO COMPLY WITH
 SEC. 1007.3 SBC 1997. SEE COMMENTS ON
 STAIR SECTIONS. SHEET 4 OF 9.
 13-PROVIDE COMPLETE WALL SECTIONS THRU
 INTERIOR BEARING WALL BY FAMILY ROOM.
 SEE COMMENTS ON SHEET 4 OF 9.
 SECTION 104.2.2 CITY AMENDMENTS TO SBC
 SAME APPLIES TO INT. WALL SECTION AT
 FRONT AREA.
 14-LAUNDRY ROOM UNDER STAIRS TO COMPLY
 WITH HEADROOM REQUIREMENTS OF SECTION
 1203.2 SBC 1997.
 15-ENG'R TO PROVIDE ORIGINAL SIGNATURE
 ON SOIL TEST REPORT AS REQUIRED BY
 CHAPTER 471 FLORIDA STATUTES.
 16-CLARIFY REINFORCEMENT FOR ENTRY COLS.
 FOUNDATION PLANS AND SECTION DETAILS
 DON'T MATCH.
 17-CLARIFY DETAIL 4 OF SHEET 8 OF 9. SEE
 COMMENTS ON PLANS.
 18-ROOF FRAMING PLAN ON SHEET 9 OF 9 IS
 VERY CONFUSING BECAUSE IT'S MIXING
 1ST AND SECOND FLOOR. ALSO, IT DOESN'T
 MATCH EXTERIOR ELEVATIONS. REVISE.
 19-PROVIDE STRUCTURAL BUCK DETAIL FOR
 EXTERIOR SWING DOORS. SEC. 104.2.2
 CITY AMENDMENTS AND SEC. 1606 SBC 1997
 20-SPECIFY CEILING INSTALLATION AT ENTRY
 AND REAR PORCHES. SEE ASTM C926 AND
 ASTM C1063 FOR PROPER SPECIFICATIONS.
 SECTION 2504.2 SBC 1997.
 21-SEE COMMENTS ON PLANS. INCLUDING
 THOSE BY THE OTHER TRADES.PLEASE BRING
 BACK REVIEWED SET AFTER CORRECTIONS
 ARE DONE TO THE ORIGINAL DRAWINGS IN
 ORDER TO EXPEDITE THE REVIEW PROCESS.
 22-REVISE ENERGY CALCULATIONS:
 A)OWNER INFORMATION IS WRONG.
 B)MAKE SURE A/C AREA MATCHES FLOOR PLANS
 ONCE THEY ARE REVISED.
 23-PROVIDE PRODUCT APPROVAL FOR:
 A)HORIZONTAL ROLLING WINDOWS (DRAWINGS
 ARE NOT LEGIBLE).
 B)SINGLE HUNG WINDOWS.
 C)POCKET SLIDING GLASS DOORS AS SHOWN ON
 ARCHITECTURAL PLANS.
 D)SLIDING GLASS DOORS (DWGS NOT LEGIBLE)
 E)ENTRY DOORS (DRAWINGS NOT LEGIBLE)
 F)8070 GARAGE DOORS DRAWINGS (COMPLETE
 AND LEGIBLEDRAWINGS).
 G)FIXED WINDOWS. SEE SIZES ON PLANS.
 H)WINDOW MULLIONS.
 I)OVAL WINDOW.
 J)AWNING WINDOWS.
 K)ARCHED WINDOWS.
  
 24-STORM PANELS:
 A)PROVIDE COMPLETE INSTALLATION SCHEDULE
 AS PER CITY SAMPLE ATTACHED.
 B)PROVIDE KEY PLAN THAT MATCHES ACTUAL
 ARCHITECTURAL PLANS.
 C)STORM SHUTTERS PRODUCT APPROVAL IS
 GOOD ONLY FOR ONE PERMIT. SEE NOTE
 ON APPROVED STORM PANEL DRAWINGS.
 D)CLEARLY INDICATE ON DRAWINGS MOUNTING
 CONDITIONS AND ANCHOR TYPE & SPACING
 TO BE USED ACCORDING TO THE DESIGN
 PRESSURES, PANEL SPAN, EDGE DISTANCE
 AND STRUCTURE TO BE ATTACHED TO (WOOD
 OR CONCRETE BLOCK).

Review Stop Z ZONING
Rev No 2 Status P Date 2002-06-20 Cont ID  
Sent By sgraham Date 2002-06-20 Time 07:54 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2002-01-26 Cont ID  
Sent By jgomez Date 2002-01-26 Time 16:56 Rev Time 0.00
Received By jgomez Date   Time   Sent To  
Notes
2002-01-26 00:00:00APPROVED BY SHIRLEY ON 1-03-02.