Plan Review Stops For Permit 01120902 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2002-03-27 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2002-03-27 |
Time |
15:19 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2002-03-27 |
Time |
15:19 |
Sent To |
|
|
Notes |
2002-03-27 00:00:00 | BUILDING PLAN REVIEW | | ******PROVISO******* | | ROBERT BROWN(561) 659 8096 EXT 8499 | | | | SBC = STANDARD BUILDING CODE 1997 | | SBC*= STANDARD BUILD'G CODE (CITY AMEND) | | | | --PROVISO-- | | A RECORDED COPY OF THE NOTICE OF | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | PERMIT CAN BE ISSUED. | | | | --PROVISO-- | | A SOIL LETTER SHALL BE SUBMITTED TO THIS | | OFFICE, SIGNED AND SEALED, CERTIFYING | | SOIL PREPARATION WAS COMPLETED AND A | | BEARING VALUE OF OF 2500 PSF HAS BEEN | | ACHIEVED BEFORE CONSTRUCTION | | | | --PROVISO-- | | A SEPARATE SHUTTER PERMIT APPLICATION IS | | REQUIRED. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2002-02-13 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2002-02-13 |
Time |
20:22 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2002-02-13 |
Time |
20:22 |
Sent To |
|
|
Notes |
2002-02-13 00:00:00 | BUILDING PLAN REVIEW | | *******DENIED******* | | ROBERT BROWN(561) 659 8096 EXT 8499 | | | | SBC = STANDARD BUILDING CODE 1997 | | SBC*= STANDARD BUILD'G CODE (CITY AMEND) | | | | 1) A RECORDED COPY OF THE NOTICE OF | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | PERMIT CAN BE ISSUED. | | | | 2) SBC 1804.1.3SHEET S-1, SECTION 1. | | THE BASE OF THE EXTERIOR WALL FOUNDATION | | SHALL BE AT LEAST 12" BELOW FINISH GRADE | | | | 3) SBC* 1804.2A SOIL REPORT SHALL BE | | SUBMITTED TO CONFIRM THE DESIGN | | ASSUMPTIONS. | | | | 4) SBC 2309.2 AND SBC* 104.2SUBMIT | | SIGNED AND SEALED TRUSS SHOP DRAWINGS | | ANDDESIGN CALCULATIONS. | | | | 5) SHEET S-1, SECTION 5 AND 'NOTE 2'. | | THE STATED 'USP' RTPGA820 AND RTPGA824 | | ARE NOT VALID USP CONNECTOR REFERENCES. | | AMEND THE NOTES TO CLARIFY THE PROPOSALS | | | | 6) SBC* 1707.4 AND SBC* 104.1.1 EXTERIOR | | DOOR ASSEMBLIES.THE SUBMITTED PRODUCT | | APPROVAL STATES THAT HURRICANE SHUTTERS | | ARE REQUIRED.A SEPARATE SHUTTER PERMIT | | APPLICATIO IS REQUIRED. | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | END OF REVIEW COMMENTS | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | IF YOU HAVE ANY QUERIES PLEASE CALL: | | ROBERT BROWN(561) 659 8096 EXT 8499 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2002-03-28 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-03-28 |
Time |
06:43 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2002-03-28 |
Time |
06:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2002-02-05 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-02-05 |
Time |
19:23 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2002-02-05 |
Time |
19:23 |
Sent To |
|
|
Notes |
2002-02-05 00:00:00 | ******************* UNSAT ************* | | | | 1)NOTE: PLEASE NOTE THAT RISER DIAGRAM | | SHOWS A MAIN BUT MAIN IS NOT SHOWN ON | | PLANS? PLEASE SHOW. | | | | 2)NOTE: PLEASE NOTE MISSING EQUIPMENT | | GROUNDING BETWEEN MAIN AND PANEL. | | 250-122 | | | | 3)NOTE: PLEASE NOTE 384-7 AND 110-26, | | PLEASE SHOW LAYOUT FOR REQ`D CLEARENCES | | FOR PANEL IN STORAGE ROOM OR LABEL | | ROOM FOR ELECTRICAL/MECH EQUIPMENT ROOM | | ONLY. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2002-02-01 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2002-02-01 |
Time |
13:45 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2002-02-01 |
Time |
13:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2002-04-23 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2002-04-23 |
Time |
16:44 |
Rev Time |
0.35 |
Received By |
pkrauss |
Date |
2002-04-23 |
Time |
16:43 |
Sent To |
|
|
Notes |
2002-04-23 00:00:00 | PROVISO:MECHANICAL PERMIT 01120942 | | | | PLEASE PROVIDE VENTILATION CALCULATIONS | | SHOWING COMPLIANCE WITH ASHRAE 62-89 FOR | | PUBLIC RESTROOMS. | | | | PLEASE PROVIDE PRIOR TO INSPECTIONS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT 659-8096 | | EXT.8388. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2002-04-23 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2002-04-20 |
Time |
17:43 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2002-04-20 |
Time |
17:43 |
Sent To |
|
|
Notes |
2002-04-20 00:00:00 | DENIED | | REFERENCE: SPC-94 - FACBC-97 | | | | 1) COMMENTS #1 AND #2 FROM PREVIOUS RE- | | VIEW NOT ADDRESSED. PLEASE ADDRESS | | PREVIOUS COMMENTS AND RESUBMIT. | | | | REVIEW BY KEN STEVENS | | (561) 659-8096 EXT 8377 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2002-02-11 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2002-02-11 |
Time |
19:29 |
Rev Time |
0.75 |
Received By |
kstevens |
Date |
2002-02-11 |
Time |
19:28 |
Sent To |
|
|
Notes |
2002-02-11 00:00:00 | DENIED | | REFERENCE: SPC-94-FACBC-97 | | | | 1) PLEASE ROUTE PLANS TO PALM BEACH | | COUNTY HEALTH UNIT, 901 EVERNIA ST WPB | | (561) 355-3018 FOR APPROVAL BEFORE SUB- | | MITTING FOR PLAN REVIEW. | | 2) BACKFLOW REQUIRED ON WATER SERVICE. | | 3) HI/LOW DRINKING FOUNTAIN REQUIRED TO | | MAKE PROVISIONS FOR THOSE WHO HAVE DIFF- | | ICULTY BENDING OR STOOPING. FACBC SEC | | 4.1.3(10) | | | | REVIEW BY KEN STEVENS | | (561) 659-8096 EXT 8377 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2002-01-30 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2002-01-30 |
Time |
15:43 |
Rev Time |
0.25 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|