Plan Review Details - Permit 01120842
Plan Review Stops For Permit 01120842
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2002-03-19 Cont ID  
Sent By jwitmer Date 2002-03-19 Time 07:30 Rev Time 0.50
Received By jwitmer Date   Time   Sent To  
Notes
2002-03-19 00:00:00***TRUSS ENGINEERING***
 1) TRUSS ENGINERING TO BE REVIEWED BY
 THE DESIGN PROFESSIONAL BEFORE SUBMITTAL
 TO THE BUILDING DEPARTMENT.
 2) ALL PRODUCTS SPECED OUT ARE SEMCO
 WHICH ARE OUT OF BUSINESS, USP LUMBER
 CONNECTORS BOUGHT THEM OUT.
 3) THE T-1 2 PLY GIRDER TRUSS HAS AN
 UPLIFT OF 3155 / 3171 LBS OF UPLIFT. THE
 ARCH SHEET A-6 INDICATES A SECTION
 12/A7 WHICH USES A SEMCO RTP 18824,
 INCREASED UPLIFT BUT WILL BE SHORT IN RE
 SISTANCE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2002-01-23 Cont ID  
Sent By jwitmer Date 2002-01-23 Time 11:26 Rev Time 2.00
Received By jwitmer Date   Time   Sent To  
Notes
2002-01-23 00:00:00MASTER 01071384 TYPE IIIJW
 PROVISO: REAR SLIDING GLASS DOORS EXCEED
 TABLE 600, WATER MANAGEMENT TRACT BEHIND
 BUILDING PERMANENT OPEN AREA.JW

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-06-10 Cont ID  
Sent By btrobaug Date 2002-06-10 Time 13:57 Rev Time 0.00
Received By btrobaug Date 2002-06-10 Time 13:39 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-01-23 Cont ID  
Sent By jwitmer Date 2002-01-23 Time 11:25 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
2002-01-23 00:00:00MASTER TYPE III 01071384 JW

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2002-06-18 Cont ID  
Sent By mcarsill Date 2002-06-18 Time 15:19 Rev Time 0.00
Received By mcarsill Date 2002-06-18 Time 15:19 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2002-01-17 Cont ID  
Sent By mcarsill Date 2002-01-17 Time 13:07 Rev Time 0.00
Received By mcarsill Date 2002-01-17 Time 13:07 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2002-01-23 Cont ID  
Sent By jwitmer Date 2002-01-23 Time 11:24 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
2002-01-23 00:00:00MASTER/TYPE III 01071384JW

Review Stop P PLUMBING
Rev No 3 Status P Date 2002-06-14 Cont ID  
Sent By kstevens Date 2002-06-14 Time 18:03 Rev Time 0.00
Received By kstevens Date 2002-06-14 Time 18:03 Sent To  
Notes
2002-06-14 00:00:00REVISION OK - SANT. RISER DIAGRAM

Review Stop P PLUMBING
Rev No 2 Status P Date 2002-01-22 Cont ID  
Sent By btrobaug Date 2002-06-10 Time 13:58 Rev Time 0.50
Received By kstevens Date 2002-01-22 Time 14:30 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-01-19 Cont ID  
Sent By jleech Date 2002-01-19 Time 11:26 Rev Time 1.50
Received By jleech Date 2002-01-19 Time 11:26 Sent To  
Notes
2002-01-19 00:00:00DENIED;
 1.PAGE A-3 AND A-10 UNIT "E". FLOOR
 PLAN AND RISER DIAGRAM ARE NOT THE
 SAME. FLOOR PLAN SHOWS SINGLE LAVS IN
 BATHROOMS. RISER DIAGRAM SHOWS TWO
 LAVS IN EACH BATHROOM.
 2.UNIT "F" FLOOR PLAN SHOWS FIVE LAVS.
 RISER DIAGRAM SHOWS SIX.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 659-8096 EXT.8369

Review Stop Z ZONING
Rev No 1 Status P Date 2002-01-15 Cont ID  
Sent By sgraham Date 2002-01-15 Time 08:13 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved