Plan Review Stops For Permit 01120842 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2002-03-19 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2002-03-19 |
Time |
07:30 |
Rev Time |
0.50 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2002-03-19 00:00:00 | ***TRUSS ENGINEERING*** | | 1) TRUSS ENGINERING TO BE REVIEWED BY | | THE DESIGN PROFESSIONAL BEFORE SUBMITTAL | | TO THE BUILDING DEPARTMENT. | | 2) ALL PRODUCTS SPECED OUT ARE SEMCO | | WHICH ARE OUT OF BUSINESS, USP LUMBER | | CONNECTORS BOUGHT THEM OUT. | | 3) THE T-1 2 PLY GIRDER TRUSS HAS AN | | UPLIFT OF 3155 / 3171 LBS OF UPLIFT. THE | | ARCH SHEET A-6 INDICATES A SECTION | | 12/A7 WHICH USES A SEMCO RTP 18824, | | INCREASED UPLIFT BUT WILL BE SHORT IN RE | | SISTANCE. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2002-01-23 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2002-01-23 |
Time |
11:26 |
Rev Time |
2.00 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2002-01-23 00:00:00 | MASTER 01071384 TYPE IIIJW | | PROVISO: REAR SLIDING GLASS DOORS EXCEED | | TABLE 600, WATER MANAGEMENT TRACT BEHIND | | BUILDING PERMANENT OPEN AREA.JW |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2002-06-10 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2002-06-10 |
Time |
13:57 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2002-06-10 |
Time |
13:39 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2002-01-23 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2002-01-23 |
Time |
11:25 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2002-01-23 00:00:00 | MASTER TYPE III 01071384 JW |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2002-06-18 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2002-06-18 |
Time |
15:19 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2002-06-18 |
Time |
15:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2002-01-17 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2002-01-17 |
Time |
13:07 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2002-01-17 |
Time |
13:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2002-01-23 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2002-01-23 |
Time |
11:24 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2002-01-23 00:00:00 | MASTER/TYPE III 01071384JW |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2002-06-14 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2002-06-14 |
Time |
18:03 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2002-06-14 |
Time |
18:03 |
Sent To |
|
|
Notes |
2002-06-14 00:00:00 | REVISION OK - SANT. RISER DIAGRAM |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2002-01-22 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2002-06-10 |
Time |
13:58 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2002-01-22 |
Time |
14:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2002-01-19 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2002-01-19 |
Time |
11:26 |
Rev Time |
1.50 |
Received By |
jleech |
Date |
2002-01-19 |
Time |
11:26 |
Sent To |
|
|
Notes |
2002-01-19 00:00:00 | DENIED; | | 1.PAGE A-3 AND A-10 UNIT "E". FLOOR | | PLAN AND RISER DIAGRAM ARE NOT THE | | SAME. FLOOR PLAN SHOWS SINGLE LAVS IN | | BATHROOMS. RISER DIAGRAM SHOWS TWO | | LAVS IN EACH BATHROOM. | | 2.UNIT "F" FLOOR PLAN SHOWS FIVE LAVS. | | RISER DIAGRAM SHOWS SIX. | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 659-8096 EXT.8369 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2002-01-15 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2002-01-15 |
Time |
08:13 |
Rev Time |
0.25 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|