Plan Review Stops For Permit 01120616 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2002-01-25 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2002-01-25 |
Time |
07:34 |
Rev Time |
0.75 |
Received By |
jwitmer |
Date |
2002-01-25 |
Time |
07:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2001-12-31 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2001-12-31 |
Time |
15:18 |
Rev Time |
3.00 |
Received By |
jwitmer |
Date |
2001-12-31 |
Time |
15:18 |
Sent To |
|
|
Notes |
2001-12-31 00:00:00 | BUILDING PLAN REVIEW | | 2400 CENTREPARK WEST DRIVE/ #175 | | PERMIT # 01120616 | | CONT. HEDRICK BROTHERS | | TEL. 689-8880 | | | | SBC= 1997 STANDARD BUILDING CODE | | SBC*= AMENDMENTS STANDARD BUILDING CODE | | | | 1)- THE ORIGINAL SHELL PERMIT FOR THE | | WAREHOUSE SHOWS THE DUMPSTER LOCATION | | AT A DIFFERENT LOCATION THAN THE TENANT | | BUILD OUT LOCATION. WILL NEED ZONING AND | | ENGINEERING APPROVAL. | | | | 2)- THE NEW GAS PUMP LOCATION WILL ALSO | | REQUIRE APPROVAL FROM ZONING AND ENGIN- | | EERING. ADDITIONAL INFORMATION WILL BE | | REQUIRED.INDICATE CODE COMPLIANCE WITH | | SECTIONS 404.2.3-404.2.7.PUMPS AND OTHER | | DISPENSING DEVISES. | | | | 3)- SHEET A-1 DOOR #116 AS INDICATED | | NEED TO SWING IN THE DIRECTION OF EGRESS | | WHEN SERVING AN OCCUPANT LOAD OF 50 OR | | MORE. OCCUPANT LOAD FOR OFFICE AREA | | ALONE OVER 50. | | | | 4)- SBC104.2.2* ADDITIONAL INFORMATION | | REQUIRED. TYPE OF BUSINESS, TYPE OF | | USEAGE FOR ROOM # 115? WAREHOUSE, TYPE | | OF MATERIALS?3'-0" DEEP RACKS, TYPE OF | | MATERIAL TO BE STORED? HEIGTH OF RACKS? | | INDICATE THE STORAGE AREAS, IT IS CRITIC | | AL THAT THE REQUIRED MEANS OF EGRESS BE | | DESIGNATED & MAINTAINED TO ENSURE THAT | | OBSTRUCTIONS BE ELIMINATED. SPECIAL | | MARKINGS OR SOME TYPE OF RAILING OR | | SCREENING MAY BE USED TO SEPERATE THE | | DESIGNATED MEANS OF EGRESS FROM THE | | STORAGE. | | | | 5)- SBC 104.2.2 ADDITIONAL INFORMATION | | ON LIFT, NOTE # 9. | | | | 6)- SHEET A-3 THE WRONG ROOM #'S ASSIGN- | | ED TO ELE. OF RESTROOMS. | | | | 7)- SBC 1204.2 SURROUNDING MATERIALS, | | THE FLOORS & WALLS OF ALL PUBLIC REST- | | ROOMS SHALL BE LINED WITH NONABSORBANT | | MATERIALS TO A HEIGTH OF 4 FT ABOVE THE | | FLOOR. | | | | 8)- FL ACCESS CODE 4.5 FLOOR SURFACES AL | | ONG ACCESSIBLE ROUTES AND IN ACCESSIBLE | | ROOMS & SPACES INCLUDING FLOORS, WALKS, | | RAMPS & STAIRS SHALL BE FIRM, SLIP- | | RESISTANT.ADDAGG 4.5 A STATIC COEFFIC- | | IENT OF FRICTION OF 0.6 IS RECOMMENDED | | FOR ACCESSIBLE ROUTES & 0.8 FOR RAMPS. | | | | 9)- MISSING FIRE SPRINKLER DRAWINGS. | | | | BUILDING PLAN REVIEW | | JIM WITMER | | (561) 659-8096 X 8412 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2002-01-22 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-01-22 |
Time |
12:55 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2002-01-22 |
Time |
12:55 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2001-12-12 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2001-12-12 |
Time |
19:34 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2001-12-12 |
Time |
19:34 |
Sent To |
|
|
Notes |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
N |
Date |
2002-01-25 |
|
|
Cont ID |
|
Sent By |
mamini |
Date |
2002-01-25 |
Time |
14:07 |
Rev Time |
0.00 |
Received By |
mamini |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2002-01-17 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2002-01-16 |
Time |
15:25 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2002-01-16 |
Time |
15:25 |
Sent To |
|
|
Notes |
2002-01-16 00:00:00 | 1) NO FIRE SPRINKLER DRAWINGS PROVIDED | | WITH PLANS. | | 2) WITH REGARDS TO FUEL TANK, THE | | FOLLOWING DETAILS ARE TO BE PROVIDED: | | A) SIZE OF TANK | | B) AGE OF TANK | | C) ANY CERTIFICATIONS ON THE TANK | | D) TYPE OF PRODUCT STORED IN THE TANK. | | E) DISTANCES FROM THE BUILDING AND | | ANY PROPERTY LINES. | | F) BOLLARD PROTECTION FROM MECHANICAL | | INJURY. | | G) VENTING OF TANK. | | H) LABELING ON THE TANK. | | THIS INSTALLATION WILL REQUIRE A | | SEPARATE PERMIT SINCE IT IS A FUEL | | INSTALLATION. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2001-12-11 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2001-12-11 |
Time |
15:46 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2001-12-11 |
Time |
15:46 |
Sent To |
|
|
Notes |
2001-12-11 00:00:00 | 1) FIRE ALARM NOTES INDICATES CLASS B, | | STYLE C CIRCUITS. ONLY CLASS A, STYLE | | D CIRCUITS WILL BE ALLOWED. | | 2) EXITING IS NOTED THRU THE HUMAN | | RESOURCE RECEPTION AND THE BOARDROOM. | | THESE DOORS CAN NEVER BE LOCKED AS THEY | | COULD PREVENT EXIT ACCESS TO THE EXITS. | | 3) NO FIRE SPRINKLER DRAWINGS PROVIDED | | WITH PLANS. | | 4) PLEASE INDICATE OCCUPANT LOAD FOR | | OPERATIONS AREA 115. IT WAS NOTED THAT | | ONE OF THE EXIT DOORS OPEN INWARDS. | | | | MIKE CARSILLO, CAPTAIN | | 659-8096,EXT.8497 | | 835-2910 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2002-01-29 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2002-01-29 |
Time |
16:57 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2002-01-25 |
Time |
15:34 |
Sent To |
|
|
Notes |
2002-01-25 00:00:00 | PROVISO ON PLAN MECH PERMIT 02011225 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2001-12-18 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2001-12-18 |
Time |
12:53 |
Rev Time |
0.50 |
Received By |
pkrauss |
Date |
2001-12-18 |
Time |
12:48 |
Sent To |
|
|
Notes |
2001-12-18 00:00:00 | *******************DENIED*************** | | | | | | PLEASE INDICATE WHAT THE "OPERATIONS" | | AREA IS USED FOR (STORAGE, REPAIR | | SHOP?). | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT 659-8096 | | EXT. 8388. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2002-01-31 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2002-01-31 |
Time |
10:27 |
Rev Time |
1.25 |
Received By |
kstevens |
Date |
2002-01-31 |
Time |
10:27 |
Sent To |
|
|
Notes |
2002-01-31 00:00:00 | PASSED/PROVISO | | | | FLOOR DRAINS REQUIRED IN BATHROOMS - | | WITH TRAP PRIMERS. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2002-01-31 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2002-01-31 |
Time |
10:29 |
Rev Time |
1.25 |
Received By |
kstevens |
Date |
2002-01-29 |
Time |
17:23 |
Sent To |
|
|
Notes |
2002-01-31 00:00:00 | PASSED/PROVISO | | | | FLOOR DRAINS REQUIRED IN BATHROOMS - | | WITH TRAP PRIMERS |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2002-01-04 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2002-01-04 |
Time |
13:42 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2002-01-04 |
Time |
13:42 |
Sent To |
|
|
Notes |
2002-01-04 00:00:00 | DENIED | | REFERENCE: SPC-94-FACBC-97 | | | | 1) SHT A-1, BUILDING DATA, MINIMUM FAC- | | ILITIES SHALL BE DETERMINED BY SPC-94 | | TABLE 407. PLEASE SUBMIT CALCULATIONS | | FOR FACILITIES USING PROPER CODE AND | | TABLE. | | | | 2) MORE INFORMATION IS REQUIRED FOR | | STORAGE FACILITIES. PLEASE INDICATE WHAT | | IS BEING STORED, SIZE OF ITEMS BEING | | STORED, AND IF THERE IS ANY HAZARDOUS | | MATERAILS BEING STORED. | | | | 3) SHT A-3, ROOMS #120 & 130, FINISH | | SCHEDULE. PER SBC SEC 1204.2 WALLS OF | | ALL PUBLIC RESTROOM SHALL BE NON-ABSOR- | | BANT WATER PROOF MATERIALS. | | | | 4) SHT A-3, PLEASE PROVIDE DETAILS FOR | | DRINKING FOUNTAINS SHOWING HEIGHT AND | | CLEAR FLOOR SPACE PER FACBC SEC 4.15 | | AND FOR THE URNAL PER FACBC SEC 4.18. | | | | REVIEW BY KEN STEVENS | | (561) 659-8096 EXT 8377 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2002-01-31 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2002-01-31 |
Time |
10:36 |
Rev Time |
0.25 |
Received By |
kstevens |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2002-01-03 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2002-01-03 |
Time |
11:11 |
Rev Time |
0.25 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2002-01-03 00:00:00 | NEED REVISED SITE PLAN & LANDSCAPING | | PLAN SHOWING SCREENING AROUND GAS PUMP |
|
|