Plan Review Details - Permit 01120137
Plan Review Stops For Permit 01120137
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-12-24 Cont ID  
Sent By dpalmer Date 2001-12-24 Time 16:53 Rev Time 0.00
Received By dpalmer Date 2001-12-24 Time 16:53 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2001-12-17 Cont ID  
Sent By hmoser Date 2001-12-17 Time 17:39 Rev Time 0.50
Received By hmoser Date 2001-12-17 Time 17:39 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2002-05-11 Cont ID  
Sent By kstevens Date 2002-05-11 Time 17:52 Rev Time 0.00
Received By kstevens Date 2002-05-11 Time 17:52 Sent To  
Notes
2002-05-11 00:00:00REVISION OK - SANT RISER DIAGRAM

Review Stop P PLUMBING
Rev No 1 Status P Date 2001-12-21 Cont ID  
Sent By kstevens Date 2001-12-21 Time 18:33 Rev Time 0.50
Received By kstevens Date 2001-12-21 Time 18:33 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2002-03-02 Cont ID  
Sent By jgomez Date 2002-03-02 Time 16:26 Rev Time 0.25
Received By jgomez Date 2002-03-02 Time 16:26 Sent To  
Notes
2002-03-02 00:00:00PRODUCT APPROVALS REVIEW.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2002-02-09 Cont ID  
Sent By jgomez Date 2002-02-09 Time 16:31 Rev Time 3.00
Received By jgomez Date 2002-02-09 Time 16:31 Sent To  
Notes
2002-02-09 00:00:00APPROVED WITH PROVISO:
 1-FLOOD ZONE AO. NEED TO PROVIDE THE
 ELEVATION CERTIFICATE.
 2-COMPLETE TWO HOUR WALL SECTION SHOWING
 ONE HOUR FIRE RATED ASSEMBLY AT INTER-
 SECTION OF 1ST FL. CONCRETE BLOCK WALL
 AND 2ND FLOOR FRAMING WALL. TABLE 600
 SBC 1997 REQUIRES ONE HOUR FIRE RATED
 WALL CONTINUOUS FROM FOOTING TO TOP PL
 3-SPECIFY ON PLANS ONE HOUR FIRE RATED
 GLASS BLOCK AT ZERO LOT LINE AS REQ'D
 BY TABLE 600 SBC 1997. SPECIFY CORRECT
 UL LISTING AND SPECS.
 4-SPECIFY DRAFSTOPPING MATERIAL AND
 LOCATION ON SECOND FLOOR FRAMING PLAN.
 SEC. 2305.2.2 SBC 1997.
 5-PROVIDE PRODUCT APPROVAL FOR:
 A)FIXED WINDOWS. SEE EXT. ELEVATIONS.
 B)ENTRY DOORS WITH LEGIBLE DRAWINGS.
  
 6-SPECIFY TRUSS ANCHOR THAT WILL RESIST
 THE UPLIFT LOADS CALCULATED ON THE
 ENGINEERED TRUSSES. SEE ENGINEERING
 FOR TRUSS WD7.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2002-01-16 Cont ID  
Sent By jgomez Date 2002-01-16 Time 18:53 Rev Time 4.00
Received By jgomez Date 2002-01-16 Time 18:53 Sent To  
Notes
2002-01-16 00:00:00CHECKLIST:
 1-NEED TO RECORD NOTICE OF COMMENCEMENT.
 2-PROVIDE EGRESS FROM LOFT AREA AS REQ'D
 BY SECTION 1005.4 SBC 1997.
 3-PROVIDE ATTIC ACCESS AT FRONT AREA OF
 FIRST FLOOR ROOF. SEC. 2309.6 SBC 1997
 AND SPECIFY SIZE OF ATTIC ACCESS
 LEADING TO FAMILY AREA ROOF.
 4-SPECIFY ONE HOUR FIRE RATED WALL FOR
 ZERO LOT LINE WOOD FRAMED WALL. AS
 REQUIRED BY TABLE 600 SBC 1997.
 NOTE: 1 HR FIRE RATED BASED ON EXTERIOR
 AND INTERIOR FIRE EXPOSURE. SEE NOTE
 I ON TABLE 600 SBC 1997.
 5-PROVIDE 29" MINIMUM CLEAR OPENING AT
 MASTER BATHROOM. SEE ENTRANCE TO WATER
 CLOSET RM. CHAPTER 11 OF FLORIDA
 ACCESSIBILITY CODE, 1997 ED.
 6-SPECIFY DRAFSTOPPING MATERIAL AND
 LOCATION ON 2ND FLOOR FRAMING PLAN.
 SEC. 2305.2.2 SBC 1997.
 7-PROVIDE COMPLETE SECTION/DETAIL FROM
 FOOTING TO ROOF AT INTERIOR FRAMED
 BEARING WALL. SPECIFY ALL FASTENERS.
 SEC. 104.2.2 CITY AMENDMENTS TO SBC/97
 8-2 STORY BEARING WALL ON SHEET 5.2
 DOESN'T MATCH FRAMING PLANS. REVISE.
 9-PROVIDE DETAILS AND COMPLETE SPECS FOR
 CEILING INSTALLATION AT ENTRY AND REAR
 PORCHES. SEE ASTM C926 AND ASTM C1063.
 10-REVISE TREAD/RISER RATIO ON STAIRS
 SECTION. SEC. 1007.3 SBC 1997.
 11-PROVIDE SMOKE DETECTOR AT FIRST FLOOR
 ALSO AS REQ'D BY SEC. 905.2.2 SBC 1997
 12-PROVIDE PRODUCT APPROVAL FOR:
 A)SINGLE HUNG WINDOWS (EXPIRED).
 B)ARCHED WINDOW (EXPIRED).
 C)1 HR GLASS BLOCK ASSEMBLY INFORMATION
 IS TOO OLD. PROVIDE CURRENT 1 HR FIRE
 RATED UL ASSEMBLY AND/OR ONE HOUR FIRE
 RATED GLASS BLOCK PRODUCT APPROVAL.
 D)ENTRY DOORS (EXPIRED).
  
 13-CONNECTORS SPECIFIED FOR TRUSS WD7
 DON'T RESIST THE UPLIFT LOADS THAT
 WERE CALCULATED ON ENGINEERED TRUSSES.
 REVISE AS REQUIRED.
 -SPECIFY CONNECTORS FOR TRUSSES FGE4 &
 FGE7. SEE ENGINEERED TRUSSES.
 14-UPDATE/REVISE ALL GENERAL TRUSS DWGS
 AS REQUIRED. SEE COMMENTS.
 15-ENGINEER OF RECORD WHO REVIEW ALL THE
 TRUSS DWGS TO CLEARLY INDICATE THE
 NAME OF FIRM WHO REVIEWED THE DWGS.
 USE STANDARD REVIEW STAMP, IF POSSIBLE
 16-SEE PLANS FOR ADDITIONAL COMMENTS AND
 BRING BACK REVIEWED SET IN ORDER TO
 EXPEDITE THE REVIEW PROCESS.

Review Stop Z ZONING
Rev No 1 Status P Date 2001-12-10 Cont ID  
Sent By sgraham Date 2001-12-10 Time 13:48 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***