Plan Review Details - Permit 01111007
Plan Review Stops For Permit 01111007
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2002-05-22 Cont ID  
Sent By rbrown Date 2002-05-22 Time 16:05 Rev Time 0.00
Received By rbrown Date 2002-05-22 Time 16:05 Sent To  
Notes
2002-05-22 00:00:00SEE REVIEW STOP 'R' FOR COMMENTS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2002-03-25 Cont ID  
Sent By sjohnson Date 2002-03-25 Time 12:31 Rev Time 0.00
Received By sjohnson Date   Time   Sent To  
Notes
2002-03-25 00:00:00APPROVED PER ROBERT BROWN 3/22/02

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2002-05-22 Cont ID  
Sent By dpalmer Date 2002-05-22 Time 16:42 Rev Time 0.00
Received By dpalmer Date 2002-05-22 Time 16:42 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2002-03-22 Cont ID  
Sent By dpalmer Date 2002-03-22 Time 06:34 Rev Time 0.00
Received By dpalmer Date 2002-03-22 Time 06:34 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2002-03-13 Cont ID  
Sent By dpalmer Date 2002-03-13 Time 17:17 Rev Time 0.00
Received By dpalmer Date 2002-03-13 Time 17:17 Sent To M
Notes
2002-03-13 00:00:00******************* UNSAT ************
 MODEL "E".
 1)NOTE: PLEASE NOTE OUTLET SPACING FOR
 KITCHEN COUNTERSPACE. 210-52-C-1
  
 2)NOTE: PLEASE NOTE MISSING OUTLET
 SPACING PER 210-52
  
 3)NOTE: PLEAS ENOTE THAT POOL PANEL IS
 STILL NOT SHOWN ON PANEL SCHEDULE?
 PLEASWE NOTE THAT RISER SHOWS POOL PANEL
 DISC AND POOL PANEL? PLEASE NOTE THAT
 POOL PANEL DISC IS SHOWN AT THE REAR OF
 HOUSE? AND POOL PANEL IN GARAGE?
 PLEASE CORRELATE LOCATIONS.
  
 4)NOTE: PLEASE NOTE THAT RISER SHOWS
 POOL PANEL BEING FED WITH TWO "HOTS"
 AND NO NEUTRAL AND NO EQUIPMENT GROUND-
 -ING CONDUCTOR?? SIZE PER 250-122
  
 5)NOTE: PLEASE GO OVER LOAD CALCULATIONS
 PLEASE REDO TO MEET ART220. THE 40%
 OF LOAD AFTER FIRST 10KW IS LOWER THAN
 IT SHOULD BE?
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2002-02-13 Cont ID  
Sent By dpalmer Date 2002-02-13 Time 18:44 Rev Time 0.00
Received By dpalmer Date 2002-02-13 Time 18:44 Sent To  
Notes
2002-02-13 00:00:00***************** UNSAT **************
 REVIEW FOR MODEL "E"
 PLEASE NOTE THAT NOT ALL ITEMS WERE
 ADDRESSED FROM FIRST REVIEW.
 PLEASE ALSO NOTE THAT OTHER CHANGES
 WERE MADE THAT NEED TO BE ADDRESSED ALSO
  
  
 1) PLEASE NOTE EITHER MISSING EGRESS
 LIGHTING AND/OR CLARIFY EGRESS LIGHTING
 PER 210-70 OF THE NEC.
 PLEASE NOTE THAT SOME WERE DONE ON SOME
 OF THE MODELS BUT NOT ALL.
  
 2) NOTE: PLEASE SHOW ALL OUTLET SPACING
 TO MEET 2`,6`,12` RULE PER 210-52.
 PLEASE NOTE SOME WERE DONE AND OTHERS??
 MISSING IN MANY LOCATIONS
 3)NOTE: PLEASE NOTE RECEPT IN GARAGE
 NEEDS TO BE SHOWN AS GFI PER 210-8
  
 4)NOTE: PLEASE CLARFIY OUTLET SHOWN
 UNDER WATER CLOSET?
  
 5)NOTE: PLEASE NOTE THAT OUTLET SPACING
 IN KITCHEN CHANGED?? SOME OUTLETS SHOWN
 AS DOUBLE INSTEAD? DID ADDRESS COMMENT
 FOR BEING GFI.
  
 6) NOTE: PLEASE SHOW GROUNDING ELECTRODE
 GOING TO BUILDING STEEL AND COLD WATER
 PER 250-50.
 FOOTER STEEL.
  
 7)NOTE: PLEASE NOTE, DERATING FOR AHU
 LOAD IS DOEN TWICE?
 PLEASE NOTE THAT LOAD CALCUALTIONS DO
 NOT MEET NEC 220.
  
 8) NOTE: SMOKE DETECTORS ARE REQUIRED
 INSIDE AND OUTSIDE ALL SLEEPING ROOMS.
 ALSO ON EACH LEVEL OF A MULTI-LEVEL
 DWELLING UNIT. ROOMS WITH BATHS AND OR
 CLOSETS ARE CONSIDERED SLEEPING ROOMS.
 PER NFPA-72 2-2.1.1.1.
 NOTE SD`S NOT TO BE WITHIN 3' OF BATHS
 AND KITCHENS. NFPA-72 2-5.2.1.6
  
 9)NOTE: PLEASE NOTE THAT RISER NOW SHOWS
 AN EQUIPMENT GROUNDING CONDUCTOR BETWEEN
 METER AND MAIN DISC. THIS IS PARALLELING
 THE NEUTRAL?
  
 10)NOTE: PLEASE NOTE THAT 30A POOL PANEL
 IS SHOWING 3/0`S FEEDING? PLEASE CLARIFY
 AND SHOW OCP ON PANEL SCHEDULE WITH
 CONDUCTOR SIZE.SHOW POOL PANEL LOCATION.
  
 11)NOTE: PLEASE NOTE THAT NOTES ON
 RIGHT STILL REFERENCE WRONG NEC FOR
 WHATS LISTED. KITCHEN NOT HAS BATH ART?
 PLEASE CORRELATE.
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372
  
 ***NOTE**
 ONLY ONE SET OF "E" PLANS WERE SUBMITTED
 PLEASE SUBMIT TWO FOR PERMITTING.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2001-12-20 Cont ID  
Sent By dpalmer Date 2001-12-20 Time 12:32 Rev Time 0.00
Received By dpalmer Date 2001-12-20 Time 12:32 Sent To  
Notes
2001-12-20 00:00:00****************** UNSAT ***************
  
  
 PLEASE SEE NOTES ATTACHED TO PERMIT `#S
 01111002 AND 01111006.
 PLEASE NOTE THE SAME NOTES FOR ALL.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-03-21 Cont ID  
Sent By pkrauss Date 2002-03-14 Time 12:37 Rev Time 0.25
Received By pkrauss Date 2002-03-14 Time 12:37 Sent To  
Notes
2002-03-14 00:00:00 
 MECHANICAL PERMIT 01111078
  
 APPROVED 12-11-01 BY H. MOSER

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2001-12-11 Cont ID  
Sent By dpalmer Date 2002-03-13 Time 17:30 Rev Time 0.33
Received By hmoser Date 2001-12-11 Time 18:32 Sent To  
Notes
2001-12-11 00:00:00IF GAS DRYERS ARE USED REFER TO SECTION
 704 COMBUSTION AIR
 STANDARD MECHANICAL CODE 1997

Review Stop P PLUMBING
Rev No 4 Status P Date 2002-03-22 Cont ID  
Sent By kstevens Date 2002-03-22 Time 11:25 Rev Time 1.00
Received By kstevens Date 2002-03-22 Time 11:24 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2002-03-12 Cont ID  
Sent By dpalmer Date 2002-03-22 Time 06:34 Rev Time 0.50
Received By kstevens Date 2002-03-12 Time 18:37 Sent To  
Notes
2002-03-12 00:00:00DENIED
 REFERENCE: SPC-94
  
 1) FROM PREVIOUS REVIEW - BATH #3 LAV
 NOT VENTED.
 2) BATH #3 HORIZONTAL DRY VENT NOT APP-
 ROVED.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop P PLUMBING
Rev No 2 Status F Date 2002-02-13 Cont ID  
Sent By kstevens Date 2002-02-13 Time 19:27 Rev Time 0.33
Received By kstevens Date 2002-02-13 Time 19:27 Sent To  
Notes
2002-02-13 00:00:00DENIED
 REFERENCE: SPC-94
  
 1) MODEL "E" - 2 SETS OF PLANS REQUIRED
 FOR PLAN REVIEW. ONLY ONE SUBMITTED.
 2) SHT A-02 BATH #2 NOT VENTED AND HORIZ
 ONTAL DRY VENT NOT ALLOWED, SEC 906.2.1
 SEE COMMENT #1 PREVIOUS REVIEW.
 3) SHT A-02 BATH #2 VENT PIPE SHALL RISE
 VERTICALLY OR AT AN ANGLE NOT EXCEEDING
 45 DEG. FROM VERTICAL TO A POINT AT
 LEAST 6" ABOVE THE FLOOD RIM LEVEL. SEC
 906.2.1
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop P PLUMBING
Rev No 1 Status F Date 2001-12-07 Cont ID  
Sent By kstevens Date 2001-12-07 Time 19:30 Rev Time 0.50
Received By kstevens Date 2001-12-07 Time 19:30 Sent To  
Notes
2001-12-07 00:00:00DENIED
 REFERENCE: SPC-94-SBC-97
  
 1) BATH #3 DRY HORIZONTAL VENT NOT
 ALLOWED PER SPC SEC 906.2.1
 2) 3" VENT NOT ALLOWED TO PASS THRU
 BLOCK WALL AND TIE BEAM PER SBC SEC
 1907.3.5
 3) MASTER BATH VENT SEE COMMENT #2.
 4) DISHWASHER TO DRAIN INTO GARBAGE DISP
 OR KITCHEN SINK TAILPIECE.
 5) BATH #2 TUB NOT VENTED PROPERLY PER
 SPC SEC 913.2
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop R ROOF PLAN REVIEW
Rev No 5 Status P Date 2002-05-22 Cont ID  
Sent By rbrown Date 2002-05-22 Time 16:07 Rev Time 0.00
Received By rbrown Date 2002-05-22 Time 16:07 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 4 Status P Date 2002-03-22 Cont ID  
Sent By rbrown Date 2002-03-22 Time 15:12 Rev Time 0.00
Received By rbrown Date 2002-03-22 Time 15:12 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status F Date 2002-03-13 Cont ID  
Sent By rbrown Date 2002-03-13 Time 15:18 Rev Time 0.00
Received By rbrown Date 2002-03-13 Time 15:18 Sent To  
Notes
2002-03-13 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 659 8096 EXT 8499
  
 1) SEE REVIEW, DATED 3/13/02, OF MODEL B
 (PERMIT NO. 01111002) FOR GENERAL
 COMMENTS.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2002-02-15 Cont ID  
Sent By rbrown Date 2002-02-15 Time 11:04 Rev Time 0.00
Received By rbrown Date 2002-02-15 Time 11:03 Sent To  
Notes
2002-02-15 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 659 8096 EXT 8499
  
 FOR CONSISTENCY, THE FOLLOWING COMMENTS
 ARE NUMBERED AS PER THE BUILDING PLAN
 REVIEW OF 1/15/02:
  
 1) SEE REVIEWS, DATED 2/14/02 & 2/15/02,
 OF MODELS B AND C (PERMIT NOS 01111002
 AND 01111005) FOR GENERAL COMMENTS.
 COMMENTS SPECIFIC TO MODEL E ARE LISTED
 BELOW.
  
 2) THIS COMMENT HAS NOT BEEN PROPERLY
 ADDRESSED.THE DOOR TYPE ELEVATION 'E'
 (SHEET A-03) DOES NOT CORRESPOND TO THE
 DOOR SHOWN ON THE REAR ELEVATION
 (SHEET A-07).
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS
 THE CODE REFERENCES GIVE ADDITIONAL INFO
 IF YOU HAVE ANY QUERIES PLEASE CALL:
 ROBERT BROWN(561) 659 8096 EXT 8499

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2002-01-15 Cont ID  
Sent By rbrown Date 2002-01-15 Time 10:01 Rev Time 0.00
Received By rbrown Date 2002-01-15 Time 10:01 Sent To  
Notes
2002-01-15 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 659 8096 EXT 8499
  
 1) SEE REVIEWS, DATED 1/15/02, OF
 MODELS B AND C (PERMIT NOS 01111002 AND
 01111005) FOR GENERAL COMMENTS. COMMENTS
 SPECIFIC TO MODEL E ARE LISTED BELOW.
  
 2) SHEET A-03, FLOOR PLAN.THE
 BATH/BED 2 EXTERIOR DOOR TO THE PATIO IS
 GIVEN A DOOR TYPE REFERENCE D, FOR WHICH
 THE DOOR TYPE ELEVATION DOES NOT
 CORRELATE TO THAT SHOWN ON THE REAR
 ELEVATION (SHEET A-07).
  
 3) SHEET A-05, ROOF PLAN.THE BEAM OVER
 THE SLIDING GLASS DOOR LEADING TO THE
 PATIO FROM THE MASTER BEDROOM HAS NO
 BEAM REFERENCE MARK SHOWN.
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS
 IF YOU HAVE ANY QUERIES PLEASE CALL:
 ROBERT BROWN(561) 659 8096 EXT 8499

Review Stop Z ZONING
Rev No 1 Status P Date 2002-01-03 Cont ID  
Sent By sgraham Date 2002-01-03 Time 09:12 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***