Plan Review Details - Permit 01111006
Plan Review Stops For Permit 01111006
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2002-05-22 Cont ID  
Sent By rbrown Date 2002-05-22 Time 15:29 Rev Time 0.00
Received By rbrown Date 2002-05-22 Time 15:29 Sent To  
Notes
2002-05-22 00:00:00SEE REVIEW STOP 'R' FOR NOTES.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2002-03-25 Cont ID  
Sent By sjohnson Date 2002-03-25 Time 12:30 Rev Time 0.00
Received By rbrown Date   Time   Sent To  
Notes
2002-03-25 00:00:00APPROVED PER ROBERT BROWN 3/22/02

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2002-03-22 Cont ID  
Sent By dpalmer Date 2002-03-22 Time 06:34 Rev Time 0.00
Received By dpalmer Date 2002-03-22 Time 06:33 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2002-03-13 Cont ID  
Sent By dpalmer Date 2002-03-13 Time 16:32 Rev Time 0.00
Received By dpalmer Date 2002-03-13 Time 16:49 Sent To M
Notes
2002-03-13 00:00:00**************** UNSAT ****************
  
 MODEL "D"
  
 1)NOTE: PLEASE NOTE OUTLET SPACING FOR
 KITCHEN COUNTERSPACE PER 210-52-C1.
  
 2)NOTE: PLEASE NOTE OUTLET SPACING FOR
 WALL SPACES. 2'6'12' RULE. 210-52
  
 3)NOTE: PLEASE NOTE POOL PANEL IS STILL
 NOT SHOWN ON MAIN PANEL SCHEUDLE?
 PLEASE NOTE THAT RISER SHOWS POOL PANEL
 DISC AND AND POOL PANEL?
 PLEASE ALSO NOTE THAT PLANS SHOWS THE
 POOL PANEL DISC AT THE REAR OF HOUSE
 AND POOL PANEL IN GARAGE?? PLEASE
 CORRELATE.
  
 4)NOTE: PLEASE NOTE THAT RISER DIAGRAM
 SHOWS POOL PANEL WITH TWO "HOTS"!, NO,
 NEUTRAL , NO EQUIPMENT GROUNDING
 CONDUCTOR. ???
  
 5)NOTE: PLEASE GO OVER LOAD CALCUALTIONS
 , PLEASE REDO TO MEET 220. THE 40% OF
 LOAD AFTER FIRST 10KW IS LOWER THAN IT
 SHOULD BE?
  
 6)NOTE: PLEASE NOTE THAT SMOKE DETECTORS
 ARE REQUIRED INSIDE AND OUTSIDE ALL
 BEDRROMS. PLEASE NOTE MISSING SD`S FOR
 IN/OUT MASTER BEDROOM. NFPA-72 2-2.1.1.1
  
 7)NOTE: PLEASE NOTE MISSING EGRESS
 LIGHTING FROM ATRIUM TO OUTSIDE.210-70
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL. PLEASE CALL IF A MEETING IS
 NEEDED.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2002-02-13 Cont ID  
Sent By dpalmer Date 2002-02-13 Time 18:23 Rev Time 0.00
Received By dpalmer Date 2002-02-13 Time 18:23 Sent To  
Notes
2002-02-13 00:00:00***************** UNSAT ***************
 REVIEW FOR MODEL "D"
 PLEASE NOTE THAT NOT ALL NOTES FROM
 FIRST REVIEW WERE ADDRESSED AND THEN
 OTHER CHANGES WERE MADE.
  
 1) PLEASE NOTE EITHER MISSING EGRESS
 LIGHTING AND/OR CLARIFY EGRESS LIGHTING
 PER 210-70 OF THE NEC.
 PLEASE NOTE THAT SOME LOCATIONS WERE
 DONE AND OTHER NOT?
  
 2) NOTE: PLEASE SHOW ALL OUTLET SPACING
 TO MEET 2`,6`,12` RULE PER 210-52.
 PLEASE NOTE STILL MISSING IN LOCATIONS
  
  
 3)NOTE: PLEASE NOTE AS CHANGES WERE
 MADE TO SHOW KITCHEN COUNTERTOPAS
 GFI`S, LOCATION WERE MOVED AND NOW DO
 NOT MEET 210-52-C1 PLEASE ALSO NOTE
 ISLAND REQ`S ADDITIONAL PER 210-52-C3
 `
 4)NOTE: PLEASE NOTE THAT ALL OTHER
 MODELS SHOW AN ATTIC ACCESS IN GARAGE
 OR OTHER? PLEASE NOTE 210-70 IF THIS
 MODEL ACCESS.
  
 5)NOTE: PLEASE NOTE THAT NOTES ON RIGHT
 STILL SHOW WRONG CODE REFERENCE FOR
 KITCHEN. SHOWS ART FOR BATHS?
  
 6)NOTE: PLEASE NOTE, LOAD CALCULATIONS
 NEED TO MEET 220. DERATING IS DONE
 TWICE FOR AHU LOAD. AND FINAL KW RATING
 IS DIVIDED BY 120VOLTS ON A 230/240 V
 SERVICE. PLEASE CORRECT.
  
 7) NOTE: PLEASE SHOW GROUNDING ELECTRODE
 GOING TO BUILDING STEEL AND COLD WATER
 PER 250-50.
  
 8)NOTE: PLEASE NOTE THAT PLANS NOW SHOW
 AN EQUIPMENT GROUNDING CONDUCTOR BETWEEN
 FIRST MEANS OF DISC AND MAIN? PLEASE
 NOTE THAT THIS IS PARALLELING THE
 NEUTRAL?
  
 9)NOTE: PLEASE NOTE THAT RISER SHOWS
 3/0`S GOING TO 30 POOL PANEL?
 PLEASE SHOW OCP AND WIRE SIZE FOR POOL
 PANEL. PLEASE SHOW PANEL LOCATION ON
 PLANS.
  
 10)NOTE: PLEASE NOTE RECEPT ON GARAGE
 NEEDS TO GFI PER 210-8.
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2001-12-20 Cont ID  
Sent By dpalmer Date 2001-12-20 Time 11:58 Rev Time 0.00
Received By dpalmer Date 2001-12-20 Time 11:58 Sent To  
Notes
2001-12-20 00:00:00************** UNSAT ******************
  
 1)NOTE: PLEASE NOTE THAT SEPARATE PLANS
 NEED TO BE SUBMITTED FOR EACH SFR.
  
 2)NOTE: PLEASE NOTE LOAD SHOWN FOR MAIN
 PANEL IS SHOWN ABOVE 200AMPS.
  
 3)NOTE: PLEASE NOTE OCP FOR WATER HEATER
 NEEDS TO BE AT 125% PER 422-13.
 PLEASE CORRELATE OCP WITH WIRE SIZE.
  
 4)NOTE: PLEASE NOTE MISSING EGRESS LIGHT
 -ING IN MANY LOCATIONS, SOME AREAS SHOWN
 WITH OPT LTS WHERE LTS ARE REQ`D 210-70
 HALLS, OUTSIDE ETC.
  
 5)NOTE: PLEASE NOTE MISSING OUTLET FOR
 A/C COND UNIT. 309-2 MECH CODE.
  
 6)NOTE: PLEASE NOTE THAT PLANS NEED TO S
 SHOW MAIN DICSA NEXT TO METER AS SHOWN
 ON RISER DIAGRAM.
  
 7) NOTE: PLEASE SHOW ALL OUTLETS SERVING
 KITCHEN COUNTERSPACE AS GFI/GFI PROTECT-
 -ED PER 210-8-A-6.
 PLEASE NOTE THAT NOTES NEED TO SHOW THE
 CORRECT ART # IF SHOWN. SHOWN AS 210-52D
 WHICH OS FOR BATHS?
  
 8)NOTE:PLEASE LIST THE REQ`D BATH(S)
 CIRCUIT(S) PER 210-11-C-3.
 MUST BE 20A AND #12AWG.
 PLEASE NOTE PLANS SHOW 210-52D AND
 AND COMES FROM 210-11-C-3
 AS LONG AS THIS IS LISTED ON PANEL
 SCHEUDULE THEN NOT REQ`D ON NOTES.
  
 9)NOTE: PLEASE CLARIFY MISSING EQUIPMENT
 GROUNDING COND PER 2505-122 FROM POOL
 PANEL TO MAIN PANEL.
  
 10)NOTE: PLEASE SHOW ALL OUTLET SPACING
 TO MEET 2`,6`,12` RULE PER 210-52.
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR]
 REVIEW. IF THERE ARE NAY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2002-06-03 Cont ID  
Sent By pkrauss Date 2002-06-03 Time 09:35 Rev Time 0.35
Received By pkrauss Date 2002-06-03 Time 09:35 Sent To  
Notes
2002-06-03 00:00:00MECHANICAL PERMIT 01111072

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2002-05-22 Cont ID  
Sent By hmoser Date 2002-05-22 Time 15:54 Rev Time 0.00
Received By hmoser Date 2002-05-22 Time 15:54 Sent To  
Notes
2002-05-22 00:00:00PLAN DENIED
 CAN NOT INSTALL RETURN AIR IN GARAGE
 AS SHOWN ON REVISION
 HAROLD MOSER 5/22/02

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-03-21 Cont ID  
Sent By pkrauss Date 2002-03-14 Time 12:28 Rev Time 0.25
Received By pkrauss Date 2002-03-14 Time 12:27 Sent To  
Notes
2002-03-14 00:00:00 
 MECHANICAL PERMIT 01111072
  
 APPROVED BY H. MOSER 12-11-02

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2001-12-11 Cont ID  
Sent By dpalmer Date 2002-03-13 Time 16:50 Rev Time 0.33
Received By hmoser Date 2001-12-11 Time 18:43 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 4 Status P Date 2002-03-22 Cont ID  
Sent By kstevens Date 2002-03-22 Time 11:24 Rev Time 1.00
Received By kstevens Date 2002-03-22 Time 11:23 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2002-03-12 Cont ID  
Sent By dpalmer Date 2002-03-22 Time 06:34 Rev Time 0.50
Received By kstevens Date 2002-03-12 Time 18:31 Sent To  
Notes
2002-03-12 00:00:00DENIED
 REFERENCE: SPC-94
  
 1) FROM PREVIOUS REVIEW - FLOOR PLAN AND
 RISER DIAGRAM DO NOT MATCH. VENT FOR TUB
 NOT SHOWN ON FLOOR PLAN IN BATH #2.
 2) FROM PREVIOUS REVIEW - VENT FROM SHR
 FROM MASTER BATH CAN NOT COME OUT OF THE
 FLOOR OF THE SHOWER.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop P PLUMBING
Rev No 2 Status F Date 2002-02-13 Cont ID  
Sent By kstevens Date 2002-02-13 Time 18:57 Rev Time 0.33
Received By kstevens Date 2002-02-13 Time 18:57 Sent To  
Notes
2002-02-13 00:00:00DENIED
 REFERENCE: SPC-94
  
 1) SHT A-02 BATH #2 VENT PIPE SHALL RISE
 VERTICALLY OR AT AN ANGLE NOT EXCEEDING
 45 DEG. FROM THE VERTICAL TO A POINT AT
 LEAST 6" ABOVE THE FLOOD RIM LEVEL. SEC
 906.2.1
 2) SHT A-02 RISER DIAGRAM, TUB IN BATH
 #2 NOT VENTED.
 3) SHT A-02 DISHWASHER NOT TRAPPED. IT
 SHALL DRAIN INTO THE GARBAGE DISPOSAL OR
 THE SINK TAILPIECE. SHOW THIS BOTH ON
 THE RISER DIAGRAM AND FLOOR PLAN.
 4) SHT A-02 VENT FOR SHOWER IN M/BATH
 CAN NOT COME OUT OF THE BOTTOM OF SHOWER
 AS SHOWN ON FLOOR PLAN. SEE COMMENT #3
 FROM PREVIOUS PLAN REVIEW.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop P PLUMBING
Rev No 1 Status F Date 2001-12-07 Cont ID  
Sent By kstevens Date 2001-12-07 Time 19:18 Rev Time 0.50
Received By kstevens Date 2001-12-07 Time 19:18 Sent To  
Notes
2001-12-07 00:00:00DENIED
 REFERENCE: SPC-94-SBC-97
  
 1) 3" STACK IN BLOCK WALL AND PASSING
 THRU A TIE BEAM NOT ALLOWED PER SBC SEC
 1907.3.5
 2) TUB IN BATH #2 NOT VENTED PROPERLY
 PER SPC SEC 913.2
 3) SHOWER FOR MASTER BATH NOT VENTED
 PROPERLY PER SPC SEC 913.2
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop R ROOF PLAN REVIEW
Rev No 5 Status P Date 2002-05-22 Cont ID  
Sent By rbrown Date 2002-05-22 Time 15:30 Rev Time 0.00
Received By rbrown Date 2002-05-22 Time 15:30 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 4 Status P Date 2002-03-22 Cont ID  
Sent By rbrown Date 2002-03-22 Time 15:13 Rev Time 0.00
Received By rbrown Date 2002-03-22 Time 15:13 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status F Date 2002-03-13 Cont ID  
Sent By rbrown Date 2002-03-13 Time 15:16 Rev Time 0.00
Received By rbrown Date 2002-03-13 Time 15:16 Sent To  
Notes
2002-03-13 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 659 8096 EXT 8499
  
 1) SEE REVIEW, DATED 3/13/02, OF MODEL B
 (PERMIT NO. 01111002) FOR GENERAL
 COMMENTS.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2002-02-15 Cont ID  
Sent By rbrown Date 2002-02-15 Time 10:40 Rev Time 0.00
Received By rbrown Date 2002-02-15 Time 10:40 Sent To  
Notes
2002-02-15 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 659 8096 EXT 8499
  
 FOR CONSISTENCY, THE FOLLOWING COMMENTS
 ARE NUMBERED AS PER THE BUILDING PLAN
 REVIEW OF 1/15/02:
  
 1) SEE REVIEWS, DATED 2/14/02 & 2/15/02,
 OF MODELS B AND C (PERMIT NOS 01111002
 AND 01111005) FOR GENERAL COMMENTS.
 COMMENTS SPECIFIC TO MODEL D ARE LISTED
 BELOW.
  
 2) THIS COMMENT HAS NOT BEEN ADDRESSED.
 NIETHER THE WINDOW SCHEDULE OR THE 'LEFT
 ELEVATION' STATES THAT THE GLASS BLOCK
 WILL HAVE A 3/4 HOUR RATING.
  
 3) THIS COMMENT HAS NOT BEEN ADDRESSED.
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS
 THE CODE REFERENCES GIVE ADDITIONAL INFO
 IF YOU HAVE ANY QUERIES PLEASE CALL:
 ROBERT BROWN(561) 659 8096 EXT 8499

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2002-01-15 Cont ID  
Sent By rbrown Date 2002-01-15 Time 09:47 Rev Time 0.00
Received By rbrown Date 2002-01-15 Time 09:47 Sent To  
Notes
2002-01-15 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 659 8096 EXT 8499
  
 SBC = STANDARD BUILDING CODE
 SBC*= STANDARD BUILD'G CODE (AMENDMENTS)
  
 1) SEE REVIEWS, DATED 1/15/02, OF
 MODELS B AND C (PERMIT NOS 01111002 AND
 01111005) FOR GENERAL COMMENTS. COMMENTS
 SPECIFIC TO MODEL D ARE LISTED BELOW.
  
 2) SBC 705.1.3OPENING PROTECTIVES.
 TABLE 600 REQUIRES THE GLASS BLOCK
 WINDOW TO THE 'NOOK' ON THE COMMON
 PROPERTY (ZERO LOT) LINE TO HAVE A FIRE
 RESISTANCE RATING OF ONE HOUR.
  
 3) SHEET A-03, FLOOR PLAN.THE BED 2
 DOOR TO THE ATRIUM IS SHOWN AS REF 21.
 THERE IS NO REFERENCE 21 SHOWN ON THE
 DOOR SCHEDULE.THE 2'-6" FRENCH DOOR
 SHOWN AT THE END OF THE SCHEDULE IS
 SHOWN AS TYPE I, AS ARE THE BI-FOLD
 DOORS.AMEND THE SCHEDULE TO GIVE
 CORRECT DOOR REF MARKS AND DOOR TYPES.
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS
 THE CODE REFERENCES GIVE ADDITIONAL INFO
 IF YOU HAVE ANY QUERIES PLEASE CALL:
 ROBERT BROWN(561) 659 8096 EXT 8499

Review Stop Z ZONING
Rev No 1 Status P Date 2002-01-03 Cont ID  
Sent By sgraham Date 2002-01-03 Time 08:45 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***