Plan Review Details - Permit 01111005
Plan Review Stops For Permit 01111005
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2002-03-25 Cont ID  
Sent By sjohnson Date 2002-03-25 Time 12:27 Rev Time 0.00
Received By sjohnson Date   Time   Sent To  
Notes
2002-03-25 00:00:00APPROVED PER ROBERT BROWN 3/22/02
 APPROVED PER ROBERT BROWN 3/22/02

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2002-03-22 Cont ID  
Sent By dpalmer Date 2002-03-22 Time 06:33 Rev Time 0.00
Received By dpalmer Date 2002-03-22 Time 06:33 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2002-03-13 Cont ID  
Sent By dpalmer Date 2002-03-13 Time 17:55 Rev Time 0.00
Received By dpalmer Date 2002-03-13 Time 17:55 Sent To M
Notes
2002-03-13 00:00:00************** UNSAT *****************
 MODEL "C".
 1) NOTE: PLEASE NOTE THAT OUTLET SPACING
 NEEDS TO MEET 210-52. 2` AND 6` RULE.
  
 2)NOTE: PLEASE NOTE LOAD CALCULATIONS
 NEED TO BE GONE OVER. PLEASE NOTE THAT
 AFTER THE FIRST 10KW WASA TAKEN, 40%
 OF REMAINING, SEEMS TO HAVE COME OUT
 TOO LOW.
 PLEASE ADJUST.
  
 3)NOTE: PLEASE NOTE POOL PANEL IS STILL
 NOT LISTED ON MAIN PANEL SCHEDULE??
 PLEASE NOTE THAT RISER SHOWS A POOL
 PANEL DISC AND POOL PANEL?
 PLEASE ALSO NOTE THAT POOL PANEL IS IN
 GARAGE AND POOL PANEL DISC IS SHOWN AT
 THE REAR OF HOUSE?? PLEASE CORRELATE.
  
 4)NOTE: PLEASE NOTE FEED TO POOL PANEL
 SHOWING TWO "HOTS"? NO NEUTRAL, NO
 EQUIPMENT GROUNDING CONDUCTOR??
 PLEASE CORRECT.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS.
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2002-02-13 Cont ID  
Sent By dpalmer Date 2002-02-13 Time 19:02 Rev Time 0.00
Received By dpalmer Date 2002-02-13 Time 19:02 Sent To  
Notes
2002-02-13 00:00:00****************** UNSAT ***************
  
 REVIEW FOR MODEL "C"
  
 PLEASE NOTE THAT NOT ALL NOTES FROM
 FIRST REVIEW WERE ADDRESSED.
 PLEASE NOTE THAT OTHER CHANGES WERE
 MADE THAT NOW NEED TO BE ADDRESSED.
  
 1) NOTE: SMOKE DETECTORS ARE REQUIRED
 INSIDE AND OUTSIDE ALL SLEEPING ROOMS.
 ALSO ON EACH LEVEL OF A MULTI-LEVEL
 DWELLING UNIT. ROOMS WITH BATHS AND OR
 CLOSETS ARE CONSIDERED SLEEPING ROOMS.
 PER NFPA-72 2-2.1.1.1.
 MISSING FIRST FLOOR.
  
 2) NOTE: PLEASE SHOW ALL OUTLET SPACING
 TO MEET 2`,6`,12` RULE PER 210-52.
 MISSING IN SOME LOCATIONS.
  
 3)NOTE: PLEASE NOTE MISSING REQ`D EGRESS
 LIGHTING AT MANY LOCATIONS. PER 210-70
  
 4) NOTE: PLEASE SHOW GROUNDING ELECTRODE
 GOING TO BUILDING STEEL AND COLD WATER
 PER 250-50.
 FOOTER STEEL.
  
 5) PLEASE NOTE MISSING OUTLET FOR A/C
 EQUIPMENT PER 210-63 OF NEC AND 309.2
 MECHANICAL CODE.
  
 6)NOTE: PLEASE NOTE THAT OUTLET SPACING
 ALONG KITCHEN COUNTERSPACES SEEM TO
 HAVE CHANGED WHEN "GFI" WAS ADDED?
 PLEASE CLARFIY "TWO" OUTLETS SHOWN
 TOGETHER. SHOWN ON OTHER MODELS LIKE
 THIS. 210-52-C1
  
 7)NOTE: PLEASE NOTE THAT NOTES ON RIGHT
 STILL REFERENCE ART FOR BATHS WHEN NOTED
 FOR KITCHEN? PLEASE CORRELATE. 210-11-C-
 1. NOTED AS 210-52D"BATHS".
  
 8)NOTE: PLEASE NOTE THAT DERATING FOR
 AHU WAS TAKEN TWICE AT 65%?? PLEASE
 CORRECT. 220
  
 9)NOTE: PLEASE NOTE LOAD CALCULATIONS
 NEED TO MEET 220. PLEASE NOTE THAT LOAD
 IS SHOWN AS BEING DIVIDED BY 120V ON
 A 230/240V SERVICE? PLEASE CLARIFY.
  
 10)NOTE: PLEASE NOTE RISER DIAGRAM WAS
 REVISED AND NOW SHOWS AN EQUIPMENT
 GROUNDING CONDUCTOR BETWEEN METER AND
 MAIN DISCONNECT? PLEASE NOTE THAT THIS
 IS PARALLELING THE NEUTRAL?
  
 11)NOTE: PLEASE NOTE MISSING HALL OUTLET
 UPSTAIRS PER 210-52H
  
 12)NOTE: PLEASE NOTE THAT RISER SHOWS
 3/0`S GOING TO A 30A POOL PANEL? PLEASE
 SHOW PANEL ON PLANS AND SHOW OCP AND
 CONDUCTOR SIZE FOR POOL PANEL ON MAIN
 PANEL SCHEDULE.
  
 13)NOTE: PLEASE NOTE MISSING REQ`D BATH
 GFI FOR POWDER ROOM FIRST FLLOR.210-52D
  
 14)NOTE: PLEASE NOTE THAT NO OUTLET IS
 SHOWING FOR RANGE. ALSO NOT SHOWN ON
 OTHER PLANS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2001-12-20 Cont ID  
Sent By dpalmer Date 2001-12-20 Time 12:30 Rev Time 0.00
Received By dpalmer Date 2001-12-20 Time 12:30 Sent To  
Notes
2001-12-20 00:00:00****************** UNSAT **********
  
 PLEASE SEE NOTE ATTACHED TO PERMIT #`S
 01111002 AND 01111006.
 PLEASE NOTE THAT SAME NOTES FOR
 ALL E-SHEETS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONSD,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW.
 561-659-8096 EXT 8372

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-03-21 Cont ID  
Sent By pkrauss Date 2002-03-14 Time 11:02 Rev Time 0.25
Received By pkrauss Date 2002-03-14 Time 10:57 Sent To  
Notes
2002-03-14 00:00:00 
 MECHANICAL PERMIT 01111065
  
 APPROVED PER HAROLD MOSER 12-11-01
 NO CHANGES WITH THIS SUBMITTAL.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2001-12-11 Cont ID  
Sent By dpalmer Date 2002-03-13 Time 18:06 Rev Time 0.33
Received By hmoser Date 2001-12-11 Time 18:47 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 4 Status P Date 2002-03-22 Cont ID  
Sent By kstevens Date 2002-03-22 Time 11:22 Rev Time 1.00
Received By kstevens Date 2002-03-22 Time 11:21 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2002-03-12 Cont ID  
Sent By dpalmer Date 2002-03-22 Time 06:33 Rev Time 0.50
Received By kstevens Date 2002-03-12 Time 18:25 Sent To  
Notes
2002-03-12 00:00:00DENIED
 REFERENCE: SPC-94
  
 1) FROM PREVIOUS REVIEW - FLOOR PLAN AND
 RISER DIAGRAM DO NOT MATCH. WASH MACHINE
 HAS NO VENT ON FLOOR PLAN..
 2) FROM PREVIOUS REVIEW - RUNNING TRAP
 AT MASTER BATH TUB IS NOT APPROVED AS
 SHOWN ON RISER DIAGRAM.
 3) FROM PREVIOUS REVIEW - LAVS AT BATH
 #2 AND MASTER BATH ARE "S" TRAPPED ON
 RISER DIAGRAM.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop P PLUMBING
Rev No 2 Status F Date 2002-02-13 Cont ID  
Sent By kstevens Date 2002-02-13 Time 18:21 Rev Time 0.50
Received By kstevens Date 2002-02-13 Time 18:21 Sent To  
Notes
2002-02-13 00:00:00DENIED
 REFERENCE: SPC-94
  
 1) SHT A-02 RISER DIAGRAM DOES NOT RE-
 FLECT FLOOR PLAN. W/M ON FLOOR PLAN IS
 AFTER RISER FOR 2ND FLOOR AND NO VENT IS
 SHOWN ON FLOOR PLAN. RISER DIAGRAM SHOWS
 W/M BEFORE RISER FOR 2ND FLOOR AND RE-
 VENT BELOW FLOOR LEVEL NOT ALLOWED. SEC
 906.3 SEE COMMENTS 3'S ONE AND TWO FROM
 PREVIOUS REVIEW.
 2) SHT A-02 FLOOR PLAN DOES NOT SHOW
 SEPARATE STACK FOR M/BATH AS SHOWN ON
 RISER. SEE COMMENT #7 FROM PREVIOUS RE-
 VIEW.
 3) SHT A-02 FLOOR PLAN SHOWS 2" VTR FOR
 POWDER ROOM & 3" VTR ON RISER DIAGRAM.
 PLEASE CLAIRFY.
 4) SHT A-02 RUNNING TRAP AT M/BATH TUB
 NOT APPROVED AS SHOWN ON RISER DIAGRAM.
 SEE COMMENT #8 FROM PREVIOUS REVIEW.
 5) SHT A-02 LAVS IN M/BATH AND BATH #2
 ARE "S" TRAPPED ON RISER DIAGRAM. THESE
 TRAPS ARE NOT APPROVED. SEC 1001.5.2
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop P PLUMBING
Rev No 1 Status F Date 2001-12-07 Cont ID  
Sent By kstevens Date 2001-12-07 Time 18:38 Rev Time 0.50
Received By kstevens Date 2001-12-07 Time 18:38 Sent To  
Notes
2001-12-07 00:00:00DENIED
 REFERENCE: SPC-94-SBC-97
  
 1) SANITARY RISER DIAGRAM DOES NOT MATCH
 FLOOR PLAN. STACK FOR BATH #2 UPSTAIRS
 SHOULD BE TAKEN OFF BEFORE W/MACHINE.
 2) W/MACHINE NOT VENTED ON RISER DIAG.
 3) LAV IN POWDER ROOM NOT VENTED ON DIAG
 4) 3" STACK NOT ALLOWED IN BLOCK WALL &
 CAN NOT PASS THRU TIE BEAM. SBC-97 SEC
 1907.3.5
 5) TUB NOT VENTED IN BATH #2, SPC SEC
 913.2
 6) DISH WASHER DRAIN SHALL GO TO GARBAGE
 DISPOSAL OR TAILPIECE ON KITCHEN SINK.
 7) DISCHARGE FROM MASTER BATH SHALL NOT
 DRAIN INTO VENT STACK FOR KITCHEN SINK.
 SPC SEC 913.2 & 910.2. SEPARATE VENT RE-
 QUIRED FOR KITCHEN SINK.
 8) RUNNING TRAPS IN MASTER BATH TUB NOT
 ALLOWED.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop R ROOF PLAN REVIEW
Rev No 4 Status P Date 2002-03-22 Cont ID  
Sent By rbrown Date 2002-03-22 Time 15:15 Rev Time 0.00
Received By rbrown Date 2002-03-22 Time 15:15 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status F Date 2002-03-13 Cont ID  
Sent By rbrown Date 2002-03-13 Time 15:13 Rev Time 0.00
Received By rbrown Date 2002-03-13 Time 15:12 Sent To  
Notes
2002-03-13 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 659 8096 EXT 8499
  
 1) SEE REVIEW, DATED 3/13/02, OF MODEL B
 (PERMIT NO. 01111002) FOR GENERAL
 COMMENTS.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2002-02-15 Cont ID  
Sent By rbrown Date 2002-02-15 Time 10:12 Rev Time 0.00
Received By rbrown Date 2002-02-15 Time 10:12 Sent To  
Notes
2002-02-15 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 659 8096 EXT 8499
  
 FOR CONSISTENCY, THE FOLLOWING COMMENTS
 ARE NUMBERED AS PER THE BUILDING PLAN
 REVIEW OF 1/15/02:
  
 1) SEE REVIEW, DATED 2/14/02, OF MODEL B
 (PERMIT NO. 01111002) FOR GENERAL
 COMMENTS.COMMENTS SPECIFIC TO MODEL C
 ARE LISTED BELOW.
  
 4) THIS COMMENT HAS NOT BEEN ADDRESSED.
 PART OF THE SECOND FLOOR BED 3 EXTERIOR
 WALL FACES THE COMMON PROPERTY LINE AT A
 DISTANCE OF 6'-8".FROM TABLE 600, THAT
 PART OF THE WALL IS REQUIRED TO HAVE A
 FIRE RESISTANCE RATING OF ONE HOUR.
 SUBMIT DETAILS TO SHOW THE RATING OF
 THIS WALL.
  
 5) THIS COMMENT HAS NOT BEEN PROPERLY
 ADDRESSED.THE MODEL D DOOR SCHEDULE IS
 STILL MISSING ALL REFERENCE MARKS ABOVE
 NO. 14
  
 6) THIS COMMENT HAS NOT BEEN PROPERLY
 ADDRESSED.SHEET A-07 REFERS TO BEAM
 REF. 8F801B BUT THIS REF. DOES NOT MATCH
 THAT SHOWN ON BEAM SCHEDULE (SHEET A-06)
 AMEND THE BEAM REFERENCE TO SUIT THAT
 GIVEN ON THE SCHEDULE.
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS
 THE CODE REFERENCES GIVE ADDITIONAL INFO
 IF YOU HAVE ANY QUERIES PLEASE CALL:
 ROBERT BROWN(561) 659 8096 EXT 8499

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2002-01-15 Cont ID  
Sent By rbrown Date 2002-01-15 Time 08:52 Rev Time 0.00
Received By rbrown Date 2002-01-15 Time 08:51 Sent To  
Notes
2002-01-15 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 659 8096 EXT 8499
  
 SBC = STANDARD BUILDING CODE
 SBC*= STANDARD BUILD'G CODE (AMENDMENTS)
  
 1) SEE REVIEW, DATED 1/15/02, OF MODEL B
 (PERMIT NO. 01111002) FOR GENERAL
 COMMENTS.COMMENTS SPECIFIC TO MODEL C
 ARE LISTED BELOW.
  
 2) THE PAD FOOTINGS UNDER GARAGE WALL
 COLUMNS AND THE PATIO COLUMN SHALL NOT
 ENCROACH ON THE COMMON PROPERTY (ZERO
 LOT) LINE.
  
 3) SHEET A-02, FOUNDATION PLAN.THE
 FOOTING SCHEDULE IS BLANK. ADD DETAILS.
  
 4) SBC 705.1.3OPENING PROTECTIVES.
 TABLE 600 REQUIRES THE SECOND FLOOR
 BED 3 EXTERIOR WALL FACING TH COMMON
 PROPERTY LINE TO HAVE A MINIMUM FIRE
 RESISTANCE RATING OF ONE HOUR.SUBMIT
 DETAILS TO SHOW THE RATING OF THIS WALL.
  
 5) MODELS C, D AND E.THE DOOR SCHEDULE
 IS MISSING ALL REFERENCE MARKS ABOVE
 NO. 14.AMEND SCHEDULES.
  
 6) SHEET A-06, BEAM SCEDULE,DOES NOT
 GIVE DETAILS FOR THE BEAMS, REF 8F01B ON
 SHEET A-07, TO THE STAIRCASE WINDOW AND
 MASTER BEDROOM WALK-IN CLOSET WINDOW.
 REVISE SCHEDULE TO SHOW BEAM TYPE & SIZE
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS
 THE CODE REFERENCES GIVE ADDITIONAL INFO
 IF YOU HAVE ANY QUERIES PLEASE CALL:
 ROBERT BROWN(561) 659 8096 EXT 8499

Review Stop Z ZONING
Rev No 1 Status P Date 2002-01-03 Cont ID  
Sent By sgraham Date 2002-01-03 Time 08:45 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***