Plan Review Stops For Permit 01110345 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2002-02-11 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2002-02-11 |
Time |
16:06 |
Rev Time |
0.75 |
Received By |
jwitmer |
Date |
2002-02-11 |
Time |
16:06 |
Sent To |
|
|
Notes |
2002-02-11 00:00:00 | BUILDING PLAN REVIEW | | PERMIT # 01110345 | | 1608 S DIXIE HWY | | CONT: CHEROKEE BUILDERS | | TELL: (561) 346-1346 | | | | SBC= 1997 STANDARD BUILDING CODE | | FL ACC= FLORIDA ACCESSIBILITY CODE 1997 | | | | 1)- FLORIDA STATE STATUTE 481.229 | | EXCEPTION 1-C: AN ARCHITECT SHALL BE RE- | | QUIRED FOR WORK IN EXCESS OF $25,000.00 | | THE ELECTRICAL NOTE #3 INDICATES VALUE | | TO LOW. THE CALCULATED VALUE IS CLOSE TO | | $79,000.00. | | | | 2)- SBC 1104.2.2 NOT ENOUDH INFORMATION | | MISSING DOOR INFO, ROOM DIMENSIONS & | | SCALE OF DRAWING,ETC. | | | | 3)- THE OWNER INDICATED THERE TO BE | | EXISTING FIRE SPRINKLERS, NO INFORMATION | | SUPPLIED. | | | | 4)- SBC TABLE 803.3 INTERIOR FINISH SCHE | | DULE NOT GIVEN. | | | | 5)- THERE IS A DEAD END CORRIDOR NEXT TO | | STORAGE AREA #1. | | | | 6)- HANDICAPPED RESTROOMS, THERE ISN'T | | A 5'-0" TURNING RADIUS, NO INFORMATION | | ON BACKING HAND RAILS NOR OTHER ELEMENTS | | THAT MAKE UP A HANDICAPPED RESTROOM. | | | | 7)- FL ACC CODE 4.13.6 THE PLANS DO NOT | | HAVE THE MANEUVERING CLEARENCES AT | | DOORWAYS. | | | | 8)- THE PLANS ARE MISSING TENANT SEPERAT | | ION, RATING, SEPERATION BETWEEN STORAGE | | AREA AND THE COMMON EXIT ACCESS CORRIDOR | | | | 9)- MISSING FLOOR/ CEILING ASSEMBLY | | TENANT SEPERATION. | | | | 10)- VENTILATION FOR RESTROOM? | | | | 11)- PUBLIC RESTROOMS SBC1204.3 | | TO BE LINED WITH AN NONABSORBANT MATER- | | IAL TO A HEIGTH OF 4'-0" ABOVE THE | | FLOOR. | | 12)- THERE IS A ROOM BETWEEN RESTROOM | | B & C THAT HAS NO ENTRY? | | | | BUILDING PLAN REVIEW | | JIM WITMER | | (561)659-8096 X8412 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2001-11-19 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2001-11-19 |
Time |
16:46 |
Rev Time |
1.00 |
Received By |
jwitmer |
Date |
2001-11-19 |
Time |
16:46 |
Sent To |
|
|
Notes |
2001-11-19 00:00:00 | BUILDING PLAN REVIEW | | PERMIT# 01110345 | | 1608 S DIXIE /SUITE | | CONT: CHEROKEE BUILDERS | | TEL: (561) 346-1346 | | SBC= 1997 STANDARD BUILDING CODE | | SBC*= AMENDMENTS/ STANDARD BUILDING CODE | | | | 1)- SBC104.2.7.* PLANS SHALL BE DRAWN TO | | A MINIMUM OF 1/8TH INCH SCALE . | | 2) TITLE BLOCK PERSON WHO IS RESPONSIBLE | | FOR DRAWING THE PLANS, TELEPHONE NUMBER | | 3)- BUILDING INFORMATION: SBC TABLE 500 | | FOR OCCUPANCY, TABLE 600 FOR MINIMUM | | BUILDING TYPE. | | 4)- INDICATE THE AMOUNT OF SQ FT IN | | TENANT SPACE. SINGLE ENTRY? | | 5)- PROPOSED RESTROOMS HANDICAPPED ACCES | | IBLE? SHOW DIMENSIONS, BACKING & INDI- | | CATE WALL AND FLOOR FINISHES. | | 6) PLANS ARE INADEQUATE TO DO A THOROUGH | | PLAN REVIEW. | | | | BUILDING PLAN REVIEW | | JIM WITMER | | (561)659-8096X8412 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2002-01-30 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-01-30 |
Time |
19:08 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2002-01-30 |
Time |
19:08 |
Sent To |
|
|
Notes |
2002-01-30 00:00:00 | ****************** UNSAT ************* | | | | 1)NOTE: PLEASE NOTE COMMENTS FROM FIRE | | PLAN REVIEW WILL NEED TO BE ADDRESSED | | DUE TO POSSIBLE ELECTRICAL CHANGES TO | | BE MADE. | | | | 2)NOTE: PLEASE NOTE/CLARIFY DEAD-END | | HALLWAY? LIGHTING? STORAGE? ECT. | | | | 3)NOTE: PLEASE NOTE TOTAL VALUE OF JOB | | WILL NEED TO BE INCREASED. PLEASE NOTE | | THAT CONTRACT FOR ELECTRICAL ALONE IS | | MORETHAN HALF THE VALUE SUBMITTED AND | | NO PLUMB/BLDG OR A/C WORK ? PLEASE | | SUBMIT CONTRACTS FOR BLDG AND PLUMB | | TO VERIFY VALUE.PER 104.6.5 ADMIN CODE | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2001-11-19 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2001-11-19 |
Time |
13:22 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2001-11-19 |
Time |
13:43 |
Sent To |
|
|
Notes |
2001-11-19 00:00:00 | ***************** UNSAT *************** | | | | 1)NOTE: PLEASE SUBMIT ELECTRICAL PLANS | | FOR REVIEW SHOWING LAYOUT FOR ANY NEW | | OUTELTS AND LIGHTING?? | | | | PLEASESUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PLAMER | | ELECTRICAL PLAN REVIEW | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
F |
Date |
2002-01-24 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2002-01-24 |
Time |
09:40 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2002-01-24 |
Time |
09:40 |
Sent To |
|
|
Notes |
2002-01-24 00:00:00 | 1) FLOOR PLAN DOES NOT INDICATE | | EMERGENCY LIGHTS OR EXIT SIGNS. | | 2) FLOOR PLAN DOES NOT INDICATE DOOR | | SIZES. | | 3) FLOOR PLAN DOES NOT INDICATE ANY | | INFORMATION REGARDING THE FIRE | | SPRINKLER SYSTEM. | | 4) FLOOR PLAN DOES NOT INDICATE INTERIOR | | FINISH CLASSIFICATION INFORMATION FOR | | WALLS AND CEILINGS. | | 5) FLOOR PLAN DOES NOT INDICATE ANY | | INFORMATION ON WHETHER THE INTERIOR | | STAIR IS RATED. | | 6) PAPER INCLUDED WITH PERMIT | | APPLICATION SHOULD BE CORRELATED TO THE | | FLOOR PLAN SO ALL INFORMATION CAN | | BE CORRECTLY DETERMINED. | | | | MIKE CARSILLO, CAPTAIN | | 659-8096,EXT.8497 | | 835-2910 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2001-11-19 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2001-11-19 |
Time |
15:24 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2001-11-19 |
Time |
15:24 |
Sent To |
|
|
Notes |
2001-11-19 00:00:00 | 1) INSUFFICIENT INFORMATION PROVIDED | | TO REVIEW SUBJECT DRAWINGS. | | | | MIKE CARSILLO, CAPTAIN | | 659-8096,EXT.8497 | | 835-2910 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
N |
Date |
2002-02-13 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2002-02-13 |
Time |
15:06 |
Rev Time |
0.25 |
Received By |
pkrauss |
Date |
2002-02-13 |
Time |
15:05 |
Sent To |
|
|
Notes |
2002-02-13 00:00:00 | | | NO MECHANICAL PLANS SUBMITTED FOR | | REVIEW.PLEASE PROVIDE PLANS WITH | | MECHANICAL PERMIT APPLICATION. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT 659-8096 | | EXT. 8388. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2001-11-19 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2001-11-19 |
Time |
12:52 |
Rev Time |
0.35 |
Received By |
pkrauss |
Date |
2001-11-19 |
Time |
12:47 |
Sent To |
E |
|
Notes |
2001-11-19 00:00:00 | | | | | NO MECHANICAL PLANS SUBMITTED FOR | | REVIEW.PLEASE PROVIDE THE FOLLOWING | | PLANS AND THE FOLLOWING INFORMATION | | WITH MECHANICAL PERMIT APPLICATION. | | | | 1.INDICATE SIZE, MATERIAL, LAYOUT AND | | CFM OF ANY NEW DUCT WORK TO BE | | INSTALLED. | | | | 2.SUBMIT MANUFACTURER DATA FOR EXHAUST | | FANS BEING INSTALLED. (1997 SMC | | 503.3.1) | | | | 3.SHOW COMPLIANCE WITH 1997 SMC 501.2. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT 659-8096 | | EXT. 8388. | | | | | | NO AIR SUPPLIED TO OFFICE OR RESTROOM. | | | | SHOW COMPLIANCE WITH 1997 SMC 501.2, AIR | | MAKE-UP FOR RESTROOM. | | | | PROVISO WRITTEN ON PLAN: | | | | 1. NO COMBUSTIBLES ABOVE THE CEILING IN | | THE RETURN AIR PLENUM. | | 1997 SMC 609.1.1. | | | | 2. FAN SHUTDOWN BY DUCT SMOKE DETECTOR | | WITH NOTIFICATION TO ALARM/STROBE IN | | NORMALLY OCCUPIED AREAS. | | NFPA 90A 4-4.4.3. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT 659-8096 | | EXT. 8388. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2002-02-11 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2002-02-11 |
Time |
08:34 |
Rev Time |
1.50 |
Received By |
kstevens |
Date |
2002-02-11 |
Time |
08:34 |
Sent To |
|
|
Notes |
2002-02-11 00:00:00 | DENIED | | REFERENCE: SPC-94-FACBC-97 | | | | 1) PLEASE PROVIDE A COPY OF THE CONTRACT | | SO SEC 4.1.6(2), 20 PERCENT OVER CONT. | | CAN BE ESTABLISHED. | | 2) PLEASE SHOW CLEAR FLOOR SPACE FOR ALL | | PLUMBING FIXTURES. | | 3) TURNING RADIUS REQUIRED TO BE 5"0", | | NOT 48" AS SHOWN. | | 4) PLEASE SHOW DETAIL FOR BACKING FOR | | GRAB BARS. | | 5) PLEASE GIVE MEASUREMENTS FOR TOILET | | ROOMS. GIVE FINISHED MEASURMENTS FOR ALL | | SHOWERS. | | 6) PLEASE SUBMIT RISER DIAGRAMS THAT ARE | | CLEAR AND READABLE. PLEASE INDICATE | | WHICH BATHROOM IS WHICH ON RISER DIAGRAM | | 3 NEW BATHROOMS BUT 4 SHOWN ON RISER DIA | | GRAM. HOW DOES 4TH BATHROOM TIE INTO THE | | REST OF THE RISER? | | 7) SANITARY RISER SHOWS SLOP SINKS BUT | | FLOOR PLAN DOES NOT SHOW ANY. | | 8) PLEASE GIVE AN ELEVATION FOR W/HEATER | | IS IT GOING TO BE ON THE FLOOR? IF ON | | SHELF A PERMINATE SHIPS LADDER WILL BE | | REQUIRED TO MAKE THE HEATER ACCESSIBLE. | | | | REVIEW BY KEN STEVENS | | (561) 659-8096 EXT 8377 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2001-11-09 |
|
|
Cont ID |
|
Sent By |
pschmitz |
Date |
2001-11-09 |
Time |
18:10 |
Rev Time |
1.00 |
Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-11-09 00:00:00 | PLUMBING PLAN REVIEW, DENIED. | | (1) CODE REFERENCES STD PLBG-94 | | SEC 104.3 PROVIDE ISOMETRIC DRAWING OF | | THE DRAIN, WASTE & VENT SYSTEM; ALSO TH | | WATER PIPING, SHOW LOCATION OF THE WATER | | HEATERS. LIST TYPES OF MATERIALS,PIPE | | SIZES. | | (2) SHOW LOCATION OF THE WATER SERVICE | | BACK FLOW PREVENTER, LOCAL ORD #2853-95. | | END OF COMMENTSPAUL SCHMITZ | | QUESTIONS561-659-8096X8233 |
|
|