Plan Review Details - Permit 01101917
Plan Review Stops For Permit 01101917
Review Stop E ELECTRICAL
Rev No 3 Status P Date 2002-05-09 Cont ID  
Sent By btrobaug Date 2002-05-09 Time 07:06 Rev Time 0.00
Received By btrobaug Date 2002-05-09 Time 06:55 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-03-04 Cont ID  
Sent By btrobaug Date 2002-03-04 Time 09:25 Rev Time 0.00
Received By btrobaug Date 2002-03-04 Time 09:25 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-11-20 Cont ID  
Sent By dpalmer Date 2001-11-20 Time 20:38 Rev Time 0.00
Received By dpalmer Date 2001-11-20 Time 20:38 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-05-06 Cont ID  
Sent By pkrauss Date 2002-05-06 Time 16:48 Rev Time 0.30
Received By pkrauss Date 2002-05-06 Time 16:48 Sent To  
Notes
2002-05-06 00:00:00MECH PERMIT 01110003

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2001-11-12 Cont ID  
Sent By btrobaug Date 2002-03-04 Time 09:25 Rev Time 0.33
Received By hmoser Date 2001-11-12 Time 10:05 Sent To  
Notes
2001-11-12 00:00:00PRIVISO
 MEED DUCT AND GRILL SIZE,C.F.M.
 FOR GUEST BATHROOM 11/12/01 H.M.

Review Stop P PLUMBING
Rev No 1 Status P Date 2001-11-20 Cont ID  
Sent By kstevens Date 2001-11-20 Time 19:12 Rev Time 0.33
Received By kstevens Date 2001-11-20 Time 19:12 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2002-02-05 Cont ID  
Sent By jgomez Date 2002-02-05 Time 13:22 Rev Time 1.50
Received By jgomez Date 2002-02-05 Time 13:21 Sent To  
Notes
2002-02-05 00:00:00APPROVED WITH PROVISO:
  
 1-PROVIDE REVISED PLANS FOR ELECTRICAL
 AND MECHANICAL WORK TO MATCH FLOOR
 PLAN SHOWING A LARGE BEDROOM #2
 INSTEAD OF TWO BEDROOMS. REVISION FEES
 WILL BE CHARGED ACCORDINGLY.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2002-01-04 Cont ID  
Sent By jgomez Date 2002-01-03 Time 18:54 Rev Time 2.50
Received By jgomez Date 2002-01-03 Time 18:54 Sent To  
Notes
2002-01-03 00:00:00SECOND CHECKLIST:
 1-ENERGY CALCULATIONS WERE NOT REVISED.
 UNDER ATTIC AREA IS INCORRECT. SEE SEC
 604.1.A.1 FLORIDA ENERGY CODE, 1997 ED
  
 NOTE:THIS ITEM WAS REQUESTED ON PREVIOUS
 CHECKLIST AND ON OTHER REVIEWS. STILL,
 ENERGY CALCS ARE RESUBMITTED UNCHANGED
  
 2-PROVIDE UPLIFT & GRAVITY CALCULATIONS
 FOR BASE DETAIL AT STEEL COLUMNS.
 ALSO, COMPLETE DETAIL SHOWING COLUMN
 MIN. EMBEDMENT ETC.
 3-CONNECTOR SPECIFIED FOR TRUSS H7B DOES
 NOT RESIST THE UPLIFT LOADS CALCULATED
 ON ENGINEERED TRUSSES.
 ALSO, CLEARLY INDICATE SIZE OF
 CONNECTOR SPECIFIED. EG: THERE ARE
 SEVERAL SIZES OF HETAL CONNECTORS.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2001-12-01 Cont ID  
Sent By jgomez Date 2001-12-01 Time 14:51 Rev Time 3.00
Received By jgomez Date 2001-12-01 Time 14:51 Sent To  
Notes
2001-12-01 00:00:00CHECKLIST:
 1-NEED RECORDED NOTICE OF COMENCEMENT.
 2-PROVIDE COMPLETE SECTION/DETAIL AT
 INTERIOR BEARING WALL BETWEEN GARAGE
 AND FOYER SHOWING RECESS AT GARAGE.
 SEE SIZE OF FOOTING SPECIFIED.
 SPECIFY ALL FASTENERS.
 3-REVISE ATTIC ACCESS SIZE AT MASTER
 BEDRM. SEE PLANS & SEC. 2309.6 SBC/97.
 ALSO, REVISE DETAIL D/2.
 4-SPECIFY CONNECTORS AT BOTTOM OF STEEL
 COLUMNS AT REAR PORCH. SEC. 104.2.2
 CITY AMENDMENTS TO SBC 1997.
 5-SPECIFY SAFETY GLASS WHERE REQUIRED.
 SEE PLANS. SEC. 2405.2 SBC 1997.
 6-CLEARLY INDICATE ON PLANS THE OPTIONS
 THAT ARE GOING TO BE BUILT. CROSS OUT
 THE OTHERS.
 7-PROVIDE PRODUCT APPROVAL FOR:
 A)FRENCH DOORS WITH SIDELITES SINGLE
 ASSEMBLY IF OPTION IS SELECTED.
 B)FIXED GLASS AT BREAKFAST AREA. SEE
 SIZE SHOWN ON PLANS.
 C)ENTRY DOORS PRODUCT APPROVAL EXPIRED.
 8-REVISE ENERGY CALCULATIONS:
 -UNDER ATTIC AREA IS INCORRECT. SEE
 SEC. 604.1.A.1 OF FL. ENERGY CODE,1997
 9-CONNECTOR SPECIFIED FOR TRUSS H7B DOES
 NOT RESIST THE UPLIFT LOADS. SEE
 ENGINEERED TRUSSES.
 10-ROOF TRUSSES:
 -UPDATE ALL GENERAL DETAILS. USE ASCE
 7-95 FOR 140MPH, NOT ASCE 7-93. SEE
 COMMENTS ON REVIEWED SET.
 11-SEE PLANS FOR ADDITIONAL COMMENTS AND
 PLEASE RETURN REVIEWED SET AFTER
 CORRECTIONS ARE DONE TO ORIGINAL DWGS
 IN ORDER TO EXPEDITE THE REVIEW.

Review Stop Z ZONING
Rev No 1 Status P Date 2001-11-02 Cont ID  
Sent By sgraham Date 2001-11-02 Time 11:18 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved