Plan Review Details - Permit 01101914
Plan Review Stops For Permit 01101914
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-04-23 Cont ID  
Sent By btrobaug Date 2002-04-23 Time 07:14 Rev Time 0.00
Received By btrobaug Date 2002-04-23 Time 06:57 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-11-20 Cont ID  
Sent By dpalmer Date 2001-11-20 Time 20:18 Rev Time 0.00
Received By dpalmer Date 2001-11-20 Time 20:18 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2001-11-12 Cont ID  
Sent By hmoser Date 2001-11-12 Time 11:22 Rev Time 0.33
Received By hmoser Date 2001-11-12 Time 11:22 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2001-11-16 Cont ID  
Sent By kstevens Date 2001-11-16 Time 21:23 Rev Time 0.33
Received By kstevens Date 2001-11-16 Time 21:23 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2002-02-04 Cont ID  
Sent By jgomez Date 2002-02-04 Time 15:46 Rev Time 1.50
Received By jgomez Date 2002-02-04 Time 15:46 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2002-01-04 Cont ID  
Sent By jgomez Date 2002-01-04 Time 12:07 Rev Time 2.50
Received By jgomez Date 2002-01-04 Time 12:07 Sent To  
Notes
2002-01-04 00:00:00SECOND CHECKLIST:
 1-ENERGY CALCULATIONS WERE NOT REVISED.
 UNDER ATTIC AREA IS INCORRECT. SEE SEC
 604.1.A.1 FLORIDA ENERGY CODE, 1997 ED
  
 NOTE: THIS ITEM WAS REQUESTED SEVERAL
 TIMES BEFORE AND STILL IS NOT DONE.
  
 2-PROVIDE UPLIFT & GRAVITY CALCULATIONS
 FOR BASE DETAIL AT STEEL COLUMNS.
 ALSO, COMPLETE DETAIL SHOWING COLUMN
 MIN. EMBEDMENT, ETC.
 3-CONNECTOR SPECIFED FOR TRUSS H7B DOES
 NOT RESIST THE UPLIFT LOADS CALCULATED
 ON ENGINEERED TRUSSES.
 ALSO, CLEARLY SPECIFY SIZE OF
 CONNECTOR SPECIFIED. THERE ARE SEVERAL
 SIZES OF HETAL OR HETA CONNECTORS.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2001-12-03 Cont ID  
Sent By jgomez Date 2001-12-03 Time 16:37 Rev Time 2.50
Received By jgomez Date 2001-12-03 Time 16:37 Sent To  
Notes
2001-12-03 00:00:00CHECKLIST:
 1-NEED NOTICE OF COMMENCEMENT.
 2-PROVIDE COMPLETE SECTION/DETAIL AT
 INTERIOR BEARING WALL BETWEEN GARAGE
 AND FOYER AREA SHOWING THE RECESS AT
 GARAGE SIDE. SEE SIZE OF FOOTING
 SPECIFIED. SPECIFY ALL FASTENERS.
 3-REVISE ATTIC ACCESS SIZE AT MASTER BED
 RM. ALSO, REVISE DETAIL D/2. SEE PLANS
 AND SECTION 2309.6 SBC 1997.
 4-PROVIDE STEEL COLUMN DETAIL SHOWING
 CONNECTORS AT BOTTOM OF COLUMN. SEC.
 104.2.2 CITY AMENDMENTS TO SBC 1997.
 5-PROVIDE PRODUCT APPROVAL FOR:
 A)FRENCH DOORS WITH SIDELITES SINGLE
 ASSEMBLY AS SHOWN ON PLANS.
 B)FIXED GLASS AT BREAKFAST AREA WITH
 SIZE SHOWN ON PLANS.
 C)ENTRY DOORS PRODUCT APPROVAL EXPIRED.
 6-REVISE ENERGY CALCULATIONS:
 -UNDER ATTIC AREA IS INCORRECT. SEE SEC
 604.1.A.1 FLORIDA ENERGY CODE, 1997 ED
 7-CONNECTOR SPECIFIED FOR TRUSS H7B DOES
 NOT RESIST THE UPLIFT LOADS CALCULATED
 8-ROOF TRUSSES:
 -UPDATE ALL GENERAL TRUSS DETAILS. USE
 ASCE 7-95 140MPH, NOT ASCE 7-93. SEE
 COMMENTS ON REVIEWED SET.
 9-SEE PLANS FOR ADDITIONAL COMMENTS.
 PLEASE RETURN REVIEWED SET AFTER
 CORRECTIONS ARE DONE TO ORIGINAL DWGS
 IN ORDER TO EXPEDITE THE REVIEW.

Review Stop Z ZONING
Rev No 1 Status P Date 2001-11-02 Cont ID  
Sent By sgraham Date 2001-11-02 Time 11:19 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***