Plan Review Details - Permit 01101800
Plan Review Stops For Permit 01101800
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-09-23 Cont ID  
Sent By jleahy Date 2004-09-23 Time 09:21 Rev Time 0.15
Received By jleahy Date 2004-09-23 Time 09:21 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-11-05 Cont ID  
Sent By dpalmer Date 2001-11-05 Time 17:39 Rev Time 0.00
Received By dpalmer Date 2001-11-05 Time 17:39 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2001-12-24 Cont ID  
Sent By ndenmark Date 2001-12-24 Time 08:06 Rev Time 0.33
Received By ndenmark Date 2001-12-24 Time 08:06 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2001-11-08 Cont ID  
Sent By pkrauss Date 2001-11-08 Time 10:29 Rev Time 0.45
Received By pkrauss Date 2001-11-08 Time 10:26 Sent To  
Notes
2001-11-08 00:00:00 
  
 NO MECHANICAL PLANS SUBMITTED FOR
 REVIEW.PLEASE PROVIDE PLANS WITH
 MECHANICAL PERMIT APPLICATION.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop P PLUMBING
Rev No 2 Status N Date 2002-02-11 Cont ID  
Sent By rmcdouga Date 2001-12-22 Time 09:05 Rev Time 0.25
Received By rmcdouga Date 2001-11-13 Time 10:47 Sent To  
Notes
2001-11-13 00:00:00SANITARY RISER DIAGRAM WILL BE SUBMITTED
 WITH PLUMBING PERMIT APPLICATION PER
 BILL NUGENT (OWNER). KS

Review Stop P PLUMBING
Rev No 1 Status F Date 2001-11-06 Cont ID  
Sent By kstevens Date 2001-11-06 Time 11:50 Rev Time 0.33
Received By kstevens Date 2001-11-06 Time 11:47 Sent To  
Notes
2001-11-06 00:00:00DENIED
 REFERENCE: SPC-94
  
 1) SANITARY RISER DIAGRAM DOES NOT COM-
 PLY WITH CODE. M/BATH SHOWER NOT VENTED,
 2ND BATH TUB NOT VENTED PROPERLY. PLEASE
 SUBMIT RISER DIAGRAM THAT MEETS CODE.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2002-02-12 Cont ID  
Sent By rmcdouga Date 2002-02-12 Time 16:59 Rev Time 2.00
Received By rmcdouga Date   Time   Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2001-12-22 Cont ID  
Sent By rmcdouga Date 2001-12-22 Time 09:07 Rev Time 2.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-12-22 00:00:00*************BUILDING UNSAT*************
  
 1) PROVIDE EMERGENCY EGRESS WINDOW IN
 THEATER ROOM WHICH COULD BE USED AS A
 SLEEPING ROOM. 97 SBC 1005.4
  
 2) THE ENERGY CALCULATION FORMS ARE
 REQUIRED TO BE SIGNED AND DATED BY THE
 OWNER/AGENT.
  
 3) THE EXTERIOR WALL WITHIN 3 FEET OF
 THE PROPERTY LINE IS REQUIRED TO HAVE A
 1 HOUR FIRE RESISTANCE RATING PER TABLE
 600 OF THE 97 SBC. EXTERIOR WALLS WITHIN
 5 FEET OF ASSUMED PROPERTY LINE MUST BE
 DESIGNED FOR FIRE RESISTANCE BY ASSUMING
 EITHER SIDE OF THE WALL TO BE EXPOSED TO
 FIRE. 97 SBC 709.6
  
 4) PROVIDE A KEY PLAN, INSTALLATION
 SCHEDULE AND INDICATE TYPE OF FASTENERS
 TO BE USED FOR STORM PANELS. INDICATE
 THAT ADEQUATE SUBSTRATE (BACKING) WILL
 BE PROVIDED AT OPENINGS FOR ATTACHING
 STORM PANELS.
  
 5) REVISED PLANS WITH CHANGES TO
 EXTERIOR WILL REQUIRE REVIEW BY THE
 HISTORIC PRESERVATION DIVISION.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2001-11-16 Cont ID  
Sent By rmcdouga Date 2001-11-16 Time 16:26 Rev Time 4.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-11-16 00:00:00*************BUILDING UNSAT*************
  
 1) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 2)PROVIDE (2) CURRENT AND COMPLETE
 COPIES OF SBCCI OR METRO-DADE PRODUCT
 APPROVALS FOR:
 - STRUCTURAL WINDOW MULLIONS
 - FRENCH DOOR
  
 3) PROVIDE (2) PRODUCT APPROVALS, KEY
 PLANS AND INSTALLATION SCHEDULES
 INDICATING THE SPECIFIC TYPES OF ANCHORS
 TO BE USED FOR STORM PANELS OR INDICATE
 THAT YOU WILL APPLY UNDER A SEPARATE
 PERMIT.
  
 4) PROVIDE INFORMATION TO INDICATE
 THAT THE ADDITION TO 735 PALM ST.AND THE
 EXISTING STRUCTURE AT 731 PALM ST. WILL
 COMPLY WITH TABLE 600 FOR THE PERCENT OF
 WALL OPENINGS PERMITTED BASED ON THE
 DISTANCE FROM THE PROPERTY LINE OR THE
 ASSUMED PROPERTY LINE BETWEEN TWO
 BUILDINGS ON THE SAME LOT. 97 SBC TABLE
 600 & SEC.504
  
 5) INDICATE ACCESS TO ATTIC TO BE A
 MINIMUM OF 22 X 36 INCHES. SBC 2309.6
  
 6) PROVIDE ONE FOUNDATION VENT OPENING
 WITHIN 3 FT OF EACH CORNER. SBC 1804.6.2
  
 7) PROVIDE ENERGY CALCULATIONS AND
 EQUIPMENT SIZING CALCULATIONS (MANUAL J)
 AS REQUIRED BY THE 1997 FLORIDA ENERGY
 EFFICIENCY CODE FOR BUILDING
 CONSTRUCTION.
  
 8) THE ROOF SHEATHING NAILING NOTE UNDER
 THE FLOOR FRAMING NOTES ON SHEET 1 IS
 NOT IN COMPLIANCE WITH GABLE END NAILING
 REQUIREMENTS FOR ZONE 3 PER CITY OF WPB
 AMENDMENTS TO 97 SBC.
  
 9) INDICATE THE METHOD OF ATTACHMENT AND
 FASTENERS THAT WILL BE USED TO CONNECT
 THE WALLS, FOOTING, ETC. OF THE NEW
 ADDITION TO THE EXISTING STRUCTURE.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202

Review Stop Z ZONING
Rev No 1 Status P Date 2001-10-31 Cont ID  
Sent By sgraham Date 2001-10-31 Time 14:07 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***