Plan Review Details - Permit 01101545
Plan Review Stops For Permit 01101545 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2001-11-02 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2001-11-02 |
Time |
07:17 |
Rev Time |
1.00 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2002-01-14 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-01-14 |
Time |
15:51 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2002-01-14 |
Time |
15:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
N |
Date |
2001-11-01 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2001-11-01 |
Time |
12:11 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2001-11-01 |
Time |
12:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2002-01-16 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2002-01-16 |
Time |
13:50 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2002-01-16 |
Time |
13:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2001-10-29 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2001-10-29 |
Time |
14:09 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2001-10-29 |
Time |
14:09 |
Sent To |
|
|
Notes |
2001-10-29 00:00:00 | 1) STAIR PRESSURIZATION TO BE TIED | | INTO BUILDING'S EMERGENCY POWER | | SYSTEM. | | 2) THE STAIR PRESSURIZATION SHALL | | PROVIDE 0.05 OF WATER COLUMN IN | | ADDITION TO STACK EFFECT EXPECTED. | | 3) STAIR PRESSURIZATION SHALL ACTIVATE | | UPON ACTIVATION OF INITIATING DEVICES | | FOR THE FIRE ALARM SYSTEM. | | | | MIKE CARSILLO, CAPTAIN | | 659-8096,EXT.8497 | | 835-2910 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2002-01-11 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2002-01-11 |
Time |
07:19 |
Rev Time |
0.40 |
Received By |
pkrauss |
Date |
2002-01-11 |
Time |
07:14 |
Sent To |
|
|
Notes |
2002-01-11 00:00:00 | | | PROVISO: | | | | TEST REQUIRED BY AN INDEPENDENT TEST AND | | BALANCE COMPANY IN THE PRESENCE OF | | MECHANICAL INSPECTOR AND FIRE INSPECTOR. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT 659-8096 | | EXT. 8388. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2001-11-01 |
|
|
Cont ID |
|
Sent By |
ndenmark |
Date |
2001-11-01 |
Time |
11:56 |
Rev Time |
0.50 |
Received By |
ndenmark |
Date |
2001-11-01 |
Time |
11:56 |
Sent To |
|
|
Notes |
2001-11-01 00:00:00 | PROVISO: | | | | ACCEPTANCE TEST OF STAIRWAY | | PRESSURIZATION REQUIRED FOR FINAL. | | CONTACT THE FIRE INSPECTOR AND MYSELF | | FOR COORDINATION OF TIME/DATE FOR TEST. | | INDEPENDANT TEST AND BALANCE COMPANY | | WILL BE REQUIRED TO CONDUCT TEST | | INCLUDING DOOR PULLS AND DIFFERENTIAL | | PRESSURE ACROSS STAIR WAY DOORS IN | | ACCORDANCE WITH NFPA 92A AND | | CONSTRUTION SERVICES MECHANICAL | | REQUIREMENTS. | | PRETEST OF SYSTEM EXPECTED PRIOR TO | | SCHEDULING TEST WITH CITY INSPECTORS | | | | ANY QUESTIONS ON TEST CRITERIA CONTACT | | NANCY DENMARK, CHIEF MECHANICAL | | INSPECTOR @ (561) 659-8096 EXT. 8221 |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
P |
Date |
2002-01-10 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2002-01-10 |
Time |
17:10 |
Rev Time |
1.50 |
Received By |
jwitmer |
Date |
2002-01-10 |
Time |
17:10 |
Sent To |
|
|
Notes |
2002-01-10 00:00:00 | REVISION # 1 01/02/01 | | CEILING DETAIL TO FOLLOW MANUFACTURERS | | SPECIFICATION FOR INSTALLATION.JW |
|
|
|