|
 |
 |
 |
 |
 |
Plan Review Details - Permit 01101544
Plan Review Stops For Permit 01101544 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2001-11-16 |
|
|
Cont ID |
|
Sent By |
hpiskura |
Date |
2001-11-16 |
Time |
15:27 |
Rev Time |
0.00 |
Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2001-12-04 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2001-12-04 |
Time |
08:32 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2001-12-04 |
Time |
08:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2001-11-05 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2001-11-05 |
Time |
19:13 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2001-11-13 |
Time |
11:13 |
Sent To |
|
|
Notes |
2001-11-05 00:00:00 | ***************** UNSAT *************** | | | | 1)NOTE: PLEASE NOTE THAT ALL CHANGES | | THAT ARE HAND DRAWN ON PLANS MUST BE | | SIGNED AND DATED BY THE ARCH OF RECORD | | PER 481.221. OF THE FS/FAC. | | | | 2)NOTE: PLEASE NOTE THAT PANEL SCHEDULE | | MENTIONS ONE NEW A/C SYSTEM AND PLANS | | SHOW TWO NEW A/C SYSTEMS? PLEASE CLARIFY | | | | | | 3)NOTE: PLEASE CLARIFY EXSITING LOAD AND | | SIZE OF EXISTING SERVICE. | | | | 4)NOTE: PLEASE NOTE THAT APPEARS THAT | | SMOKE DETECTORS ARE BEING INSTALLED TO | | MEET CODE. PLEASE NOTE ONLY MISSING ONE | | ON LOWER LEVEL. NFPA-72 2-2.1.1.1 | | | | 5) NOTE: PLEASE LIST THE REQ`D BATH(S) | | CIRCUIT(S) PER 210-11-C-3. | | MUST BE 20A AND #12AWG. | | | | 6)NOTE: PLEASE NOTE MISSING ONE OUTLET | | SERVING KITCHEN COUNTERSPACE TO BE SHOWN | | AS GFI. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2001-11-08 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2001-11-08 |
Time |
10:39 |
Rev Time |
0.40 |
Received By |
pkrauss |
Date |
2001-11-08 |
Time |
10:36 |
Sent To |
|
|
Notes |
2001-11-08 00:00:00 | | | | | NO MECHANICAL PLANS SUBMITTED FOR | | REVIEW.PLEASE PROVIDE PLANS WITH | | MECHANICAL PERMIT APPLICATION. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT 659-8096 | | EXT. 8388. | | *******************DENIED*************** | | | | | | PLEASE PROVIDE OUTSIDE AIR CALCULATIONS | | AS PER ASHRAE 62-89.INDICATE O.A. ON | | PLAN. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT 659-8096 | | EXT. 8388. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2002-02-24 |
|
|
Cont ID |
|
Sent By |
pschmitz |
Date |
2002-02-24 |
Time |
14:53 |
Rev Time |
1.00 |
Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2002-02-24 00:00:00 | REVISION ADD 2ND FLR BAR SINK. PES |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2001-11-07 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2001-11-07 |
Time |
09:49 |
Rev Time |
0.33 |
Received By |
kstevens |
Date |
2001-11-07 |
Time |
09:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2002-01-23 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2002-01-23 |
Time |
09:37 |
Rev Time |
0.25 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2001-10-26 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2001-10-26 |
Time |
14:07 |
Rev Time |
0.25 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |