Plan Review Details - Permit 01101505
Plan Review Stops For Permit 01101505
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-03-06 Cont ID  
Sent By dpalmer Date 2002-03-06 Time 06:36 Rev Time 0.00
Received By dpalmer Date 2002-03-06 Time 06:35 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-11-07 Cont ID  
Sent By dpalmer Date 2001-11-07 Time 10:48 Rev Time 0.00
Received By dpalmer Date 2001-11-07 Time 10:48 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 4 Status F Date 2002-03-15 Cont ID  
Sent By pkrauss Date 2002-03-15 Time 09:00 Rev Time 0.35
Received By pkrauss Date   Time   Sent To  
Notes
2002-03-15 00:00:00 
 MISSING DUCT SIZES - SEE PLAN.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2002-02-12 Cont ID  
Sent By kstevens Date 2002-03-13 Time 09:46 Rev Time 0.30
Received By pkrauss Date 2002-02-12 Time 07:09 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2001-12-12 Cont ID  
Sent By pkrauss Date 2001-12-12 Time 13:49 Rev Time 0.10
Received By pkrauss Date 2001-12-12 Time 13:49 Sent To  
Notes
2001-12-12 00:00:00MECH PERMIT 01120622...APOLLO AIR

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2001-11-06 Cont ID  
Sent By hmoser Date 2001-11-06 Time 20:13 Rev Time 0.33
Received By hmoser Date 2001-11-06 Time 20:12 Sent To  
Notes
2001-11-06 00:00:00NO MECHANICAL PERMIT NUMBER ON THIS
 APPLICATION 11/06/01H.M.

Review Stop P PLUMBING
Rev No 2 Status P Date 2002-03-13 Cont ID  
Sent By kstevens Date 2002-03-13 Time 09:45 Rev Time 0.33
Received By kstevens Date 2002-03-13 Time 09:45 Sent To M
Notes
2002-03-13 00:00:00REVISION OK - (NEW PLANS) SANT RISER DIA

Review Stop P PLUMBING
Rev No 1 Status P Date 2001-11-06 Cont ID  
Sent By dpalmer Date 2002-03-06 Time 06:36 Rev Time 0.33
Received By jleech Date 2001-11-06 Time 17:36 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status F Date 2002-03-05 Cont ID  
Sent By jgomez Date 2002-03-05 Time 11:52 Rev Time 1.00
Received By jgomez Date 2002-03-05 Time 11:51 Sent To  
Notes
2002-03-05 00:00:00CHECKLIST:
 1-ENERGY CALCULATIONS ARE WRONG AGAIN.
 NOW THE UNDER ATTIC IS LESS THAN THE
 A/C AREA. WHY?
 -CLARIFY IF WORST CASE SCENARIO OR NOT
 SINCE THIS MODEL IS USED ALL OVER THE
 PLACE.
  
  
  
 NOTES:
 -REVISIONS TO PLANS ARE OK.
 -TRUSS DRAWINGS ARE OK.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2001-12-05 Cont ID  
Sent By jgomez Date 2001-12-05 Time 18:19 Rev Time 0.25
Received By jgomez Date 2001-12-05 Time 18:19 Sent To  
Notes
2001-12-05 00:00:00APPROVED WITH PROVISO. RECEIVED REVISED
 SOIL TEST REPORT. SEE PROVISO NOTES
 ON PREVIOUS REVIEW DATED 11-29-01.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status   Date   Cont ID  
Sent By jgomez Date 2001-11-29 Time 14:16 Rev Time 2.00
Received By jgomez Date 2001-11-29 Time 14:16 Sent To  
Notes
2001-11-29 00:00:00APPROVED WITH PROVISO:
 1-FLOOD ZONE AO: WILL NEED THE ELEVATION
 CERTIFICATE.
 2-REVISE ENERGY CALCULATIONS:
 -REVISE UNDER ATTIC AREA. SEE SECTION
 604.1.A.1 FL. ENERGY CODE, 1997.
 3-PROVIDE CURRENT UL ASSEMBLY FOR FIRE
 RATED GLASS BLOCK ASSEMBLY.
 4-PROVIDE UPDATED PRODUCT APPROVAL FOR
 ENTRY DOORS.
 5-PROVIDE STRUCTURAL HANGING DETAIL FOR
 AHU. SPECIFY ALL CONNECTORS. SECTION
 104.2.2 CITY AMENDMENTS TO SBC 1997.
 6-REVISE WINDOW SIZE FOR BEDROOM #3:
 24 SH WINDOW DOESN'T PROVIDE THE 24"
 MIN. CLEAR HEIGHT OPENING REQUIRED BY
 SEC. 1005.4 SBC 1997.
 7-SPECIFY SAFETY GLASS WHERE REQUIRED.
 SEE PLANS AND SEC. 2405.2 SBC 1997.
 8-TRUSS DRAWINGS:
 -UPDATE GENERAL DETAILS. USE ASCE 7-95
 FOR 140 MPH NOT, ASCE 7-93 FOR 110MPH.
 -SEE GENERAL DETAILS FOR COMMENTS.
 -MAKE SURE ALL DETAILS ARE LEGIBLE.
 -REVIEW STAMP DOESN'T IDENTIFY THE
 NAME OF FIRM WHO REVIEWED ALL TRUSS
 DRAWINGS. ENGINEER OF RECORD DOESN'T
 NEED TO SEAL THE TRUSS LAYOUT. JUST
 USE THE STANDARD REVIEW STAMP.
 9-REVISE THE ROOF SHEATHING SPECS ON
 THE TYPICAL WALL SECTION. SEE SECTION
 2306 OF CITY AMENDMENTS TO SBC 1997.
 10-SOIL TEST REPORT ENGINEER TO PROVIDE
 ORIGINAL SIGNATURE AS REQUIRED BY
 CHAPTER 471 OF FLORIDA STATUTES.

Review Stop Z ZONING
Rev No 1 Status P Date 2001-10-30 Cont ID  
Sent By sgraham Date 2001-10-30 Time 11:45 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***