Plan Review Stops For Permit 01101505 |
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2002-03-06 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-03-06 |
Time |
06:36 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2002-03-06 |
Time |
06:35 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2001-11-07 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2001-11-07 |
Time |
10:48 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2001-11-07 |
Time |
10:48 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
F |
Date |
2002-03-15 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2002-03-15 |
Time |
09:00 |
Rev Time |
0.35 |
Received By |
pkrauss |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2002-03-15 00:00:00 | | | MISSING DUCT SIZES - SEE PLAN. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT 659-8096 | | EXT. 8388. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2002-02-12 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2002-03-13 |
Time |
09:46 |
Rev Time |
0.30 |
Received By |
pkrauss |
Date |
2002-02-12 |
Time |
07:09 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2001-12-12 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2001-12-12 |
Time |
13:49 |
Rev Time |
0.10 |
Received By |
pkrauss |
Date |
2001-12-12 |
Time |
13:49 |
Sent To |
|
|
Notes |
2001-12-12 00:00:00 | MECH PERMIT 01120622...APOLLO AIR |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2001-11-06 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2001-11-06 |
Time |
20:13 |
Rev Time |
0.33 |
Received By |
hmoser |
Date |
2001-11-06 |
Time |
20:12 |
Sent To |
|
|
Notes |
2001-11-06 00:00:00 | NO MECHANICAL PERMIT NUMBER ON THIS | | APPLICATION 11/06/01H.M. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2002-03-13 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2002-03-13 |
Time |
09:45 |
Rev Time |
0.33 |
Received By |
kstevens |
Date |
2002-03-13 |
Time |
09:45 |
Sent To |
M |
|
Notes |
2002-03-13 00:00:00 | REVISION OK - (NEW PLANS) SANT RISER DIA |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2001-11-06 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-03-06 |
Time |
06:36 |
Rev Time |
0.33 |
Received By |
jleech |
Date |
2001-11-06 |
Time |
17:36 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
3 |
Status |
F |
Date |
2002-03-05 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2002-03-05 |
Time |
11:52 |
Rev Time |
1.00 |
Received By |
jgomez |
Date |
2002-03-05 |
Time |
11:51 |
Sent To |
|
|
Notes |
2002-03-05 00:00:00 | CHECKLIST: | | 1-ENERGY CALCULATIONS ARE WRONG AGAIN. | | NOW THE UNDER ATTIC IS LESS THAN THE | | A/C AREA. WHY? | | -CLARIFY IF WORST CASE SCENARIO OR NOT | | SINCE THIS MODEL IS USED ALL OVER THE | | PLACE. | | | | | | | | NOTES: | | -REVISIONS TO PLANS ARE OK. | | -TRUSS DRAWINGS ARE OK. |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
P |
Date |
2001-12-05 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2001-12-05 |
Time |
18:19 |
Rev Time |
0.25 |
Received By |
jgomez |
Date |
2001-12-05 |
Time |
18:19 |
Sent To |
|
|
Notes |
2001-12-05 00:00:00 | APPROVED WITH PROVISO. RECEIVED REVISED | | SOIL TEST REPORT. SEE PROVISO NOTES | | ON PREVIOUS REVIEW DATED 11-29-01. |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2001-11-29 |
Time |
14:16 |
Rev Time |
2.00 |
Received By |
jgomez |
Date |
2001-11-29 |
Time |
14:16 |
Sent To |
|
|
Notes |
2001-11-29 00:00:00 | APPROVED WITH PROVISO: | | 1-FLOOD ZONE AO: WILL NEED THE ELEVATION | | CERTIFICATE. | | 2-REVISE ENERGY CALCULATIONS: | | -REVISE UNDER ATTIC AREA. SEE SECTION | | 604.1.A.1 FL. ENERGY CODE, 1997. | | 3-PROVIDE CURRENT UL ASSEMBLY FOR FIRE | | RATED GLASS BLOCK ASSEMBLY. | | 4-PROVIDE UPDATED PRODUCT APPROVAL FOR | | ENTRY DOORS. | | 5-PROVIDE STRUCTURAL HANGING DETAIL FOR | | AHU. SPECIFY ALL CONNECTORS. SECTION | | 104.2.2 CITY AMENDMENTS TO SBC 1997. | | 6-REVISE WINDOW SIZE FOR BEDROOM #3: | | 24 SH WINDOW DOESN'T PROVIDE THE 24" | | MIN. CLEAR HEIGHT OPENING REQUIRED BY | | SEC. 1005.4 SBC 1997. | | 7-SPECIFY SAFETY GLASS WHERE REQUIRED. | | SEE PLANS AND SEC. 2405.2 SBC 1997. | | 8-TRUSS DRAWINGS: | | -UPDATE GENERAL DETAILS. USE ASCE 7-95 | | FOR 140 MPH NOT, ASCE 7-93 FOR 110MPH. | | -SEE GENERAL DETAILS FOR COMMENTS. | | -MAKE SURE ALL DETAILS ARE LEGIBLE. | | -REVIEW STAMP DOESN'T IDENTIFY THE | | NAME OF FIRM WHO REVIEWED ALL TRUSS | | DRAWINGS. ENGINEER OF RECORD DOESN'T | | NEED TO SEAL THE TRUSS LAYOUT. JUST | | USE THE STANDARD REVIEW STAMP. | | 9-REVISE THE ROOF SHEATHING SPECS ON | | THE TYPICAL WALL SECTION. SEE SECTION | | 2306 OF CITY AMENDMENTS TO SBC 1997. | | 10-SOIL TEST REPORT ENGINEER TO PROVIDE | | ORIGINAL SIGNATURE AS REQUIRED BY | | CHAPTER 471 OF FLORIDA STATUTES. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2001-10-30 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2001-10-30 |
Time |
11:45 |
Rev Time |
0.25 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|