Plan Review Details - Permit 01101438
Plan Review Stops For Permit 01101438
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-11-14 Cont ID  
Sent By dpalmer Date 2001-11-14 Time 17:10 Rev Time 0.00
Received By dpalmer Date 2001-11-14 Time 17:10 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-01-16 Cont ID  
Sent By pkrauss Date 2002-01-16 Time 07:41 Rev Time 0.30
Received By pkrauss Date 2002-01-16 Time 07:36 Sent To  
Notes
2002-01-16 00:00:00MECHANICAL CONTRACTOR NOT SIGNED ON THE
 MASTER PERMIT.MECHANICAL PERMIT
 REQUIRED.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2001-11-07 Cont ID  
Sent By hmoser Date 2001-11-07 Time 19:18 Rev Time 0.33
Received By hmoser Date 2001-11-07 Time 19:18 Sent To  
Notes
2001-11-07 00:00:00NO MECHANICAL PERMIT NUMBER ON THIS
 APPLICATION 11/07/01H.M.

Review Stop P PLUMBING
Rev No 1 Status P Date 2001-11-06 Cont ID  
Sent By jleech Date 2001-11-06 Time 18:30 Rev Time 0.33
Received By jleech Date 2001-11-06 Time 18:30 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2002-02-23 Cont ID  
Sent By jgomez Date 2002-02-23 Time 17:19 Rev Time 0.33
Received By jgomez Date 2002-02-23 Time 17:19 Sent To  
Notes
2002-02-23 00:00:00TRUSS DRAWINGS AND REVISED DWG.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2002-01-22 Cont ID  
Sent By jgomez Date 2002-01-22 Time 18:49 Rev Time 3.00
Received By jgomez Date 2002-01-22 Time 18:49 Sent To  
Notes
2002-01-22 00:00:00APPROVED WITH PROVISO:
 1-FLOOD ZONE AO. NEED THE ELEVATION
 CERTIFICATE.
 2-PROVIDE ENTRY DOORS PRODUCT APPROVAL
 WITH LEGIBLE DRAWINGS.
 3-ENGINEER OF RECORD TO REVISE THE
 STRUCTURAL BUCK DETAIL SHOWING A 2X
 BUCK DETAIL AS REQUIRED ON THE PRODUCT
 APPROVAL USED FOR ENTRY DOORS.
 4-TRUSS DRAWINGS 2ND REVIEW:
 *CONTRACTOR CHANGED TRUSS COMPANY.
 A)UPDATE ALL GENERAL TRUSS DETAILS.
 B)THERE ARE 2 ENGINNERS SEALING THE
 GENERAL TRUSS DETAILS. COMPLY WITH
 REQUIREMENTS OF FLORIDA ENGINEER BOARD
 WHEN AN ENGINEER'S TAKEN OTHER'S WORK.
 C)PROVIDE LEGIBLE & COMPLETE GENERAL
 TRUSS DETAILS.
 D)ENGINEERED TRUSSES ARE DESIGNED USING
 ASCE 7-98. NEED TO USE THE RIGHT WIND
 ZONE. IT IS 140MPH, NOT 110 MPH WIND.
 -ALSO, USE THE MEAN ROOF HEIGHT. THIS
 BLDG HAS AN SLOPED ROOF, NOT FLAT ROOF

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status   Date   Cont ID  
Sent By jgomez Date 2001-11-28 Time 15:39 Rev Time 2.50
Received By jgomez Date 2001-11-28 Time 15:39 Sent To  
Notes
2001-11-28 00:00:00APPROVED WITH PROVISO:
 1-FLOOD ZONE AO: NEED THE ELEVATION
 CERTIFICATE.
 2-REVISE ENERGY CALCULATIONS:
 -UNDER ATTIC AREA IS INCORRECT. SEE
 SECTION 604.1.A.1 OF FL. ENERGY CODE.
 -REVISE NUMBER OF BEDROOMS. SEE BEDRM
 DEFINITION ON FL. ENERGY CODE.
 3-GLASS BLOCK INFORMATION IS TOO OLD.
 YEAR 1992. PROVIDE CURRENT UL FIRE
 RATED ASSEMBLY NUMBER.
 4-PROVIDE UPDATED PRODUCT APPROVAL FOR
 ENTRY DOORS.
 5-TRUSS DRAWINGS:
 -UPDATE GENERAL DETAILS. USE SBC 1997
 FOR 110MPH OR ASCE 7-95 FOR 140MPH.
 SEE COMMENTS ENGINEERED TRUSSES.
 -SOME DETAILS ARE NOT LEGIBLE.
 -REVIEW STAMP BY ENGINEER DOESN'T
 IDENTIFY THE FIRM WHO REVIEW THE TRUSS
 DRAWINGS. PROFESSIONAL ENGINEER OF
 RECORD DOESN'T HAVE TO SEAL THE TRUSS
 LAYOUT. HE ONLY NEEDS THE REVIEW STAMP,
 BUT IDENTIFYING HIS NAME OR COMPANY.
 6-PROVIDE STRUCTURAL HANGING DETAIL FOR
 AHU. SPECIFY ALL CONNECTORS. SECTION
 104.2.2 CITY AMENDMENTS TO SBC 1997.
 7-SPECIFY SAFETY GLASS WHERE REQUIRED.
 SEE PLANS AND SEC. 2405.2 SBC 1997.
 8-REVISE THE ROOF SHEATHING SPECS ON TYP
 WALL SECTION. SEE SECTION 2306 OF CITY
 AMENDMENTS TO SBC 1997.
 9-SOIL TEST REPORT ENGINEER TO PROVIDE
 ORIGINAL SIGNATURE AS REQUIRED BY
 CHAPTER 471 FLORIDA STATUTES.
 10-REVISE SIZE OF WINDOW BEDROOM #3.
 24SH WINDOW DOESN'T PROVIDE THE 24"
 MIN. CLEAR HEIGHT REQUIREMENT OF
 SECTION 1005.4 SBC 1997.

Review Stop Z ZONING
Rev No 1 Status P Date 2001-11-01 Cont ID  
Sent By sgraham Date 2001-11-01 Time 13:19 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***