Plan Review Details - Permit 01101437
Plan Review Stops For Permit 01101437
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-11-20 Cont ID  
Sent By dpalmer Date 2001-11-20 Time 20:24 Rev Time 0.00
Received By dpalmer Date 2001-11-20 Time 20:24 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2002-04-16 Cont ID  
Sent By pkrauss Date 2002-04-16 Time 15:49 Rev Time 0.40
Received By pkrauss Date 2002-04-16 Time 15:49 Sent To  
Notes
2002-04-16 00:00:00MECH PERMIT 02040674

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-03-20 Cont ID  
Sent By pkrauss Date 2002-03-20 Time 12:24 Rev Time 0.35
Received By pkrauss Date 2002-03-20 Time 12:24 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2001-11-12 Cont ID  
Sent By hmoser Date 2001-11-12 Time 11:08 Rev Time 0.33
Received By hmoser Date 2001-11-12 Time 11:08 Sent To  
Notes
2001-11-12 00:00:00NO MECHANICAL PERMIT NUMBER ON THIS
 APPLICATION 11/12/01 H.M.

Review Stop P PLUMBING
Rev No 1 Status P Date 2001-11-16 Cont ID  
Sent By kstevens Date 2001-11-16 Time 21:19 Rev Time 0.33
Received By kstevens Date 2001-11-16 Time 21:18 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 4 Status P Date 2002-07-09 Cont ID  
Sent By jgomez Date 2002-07-09 Time 12:18 Rev Time 0.00
Received By jgomez Date 2002-07-09 Time 12:18 Sent To  
Notes
2002-07-09 00:00:00CONCRETE SLAB PATIO REVISION.

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2002-03-15 Cont ID  
Sent By jgomez Date 2002-03-15 Time 11:15 Rev Time 3.00
Received By jgomez Date 2002-03-15 Time 11:15 Sent To  
Notes
2002-03-15 00:00:00APPROVED WITH PROVISO:
 1-FLOOD ZONE AO. NEED THE ELEVATION
 CERTIFICATE.
 2-FOR FUTURE SUBMITTALS SPECIFY ON PLANS
 THAT GLASS BLOCK NEEDS TO BE ONE HOUR
 FIRE RATED ASSEMBLY FOR WALLS ON THE
 ZERO LOT LINE. TABLE 600 SBC 1997.
 3-PROVIDE COMPLETE STRUCTURAL DETAIL AND
 SPECIFICATIONS FOR INSTALLATION OF
 HANGING AIR HANDLER UNITS.
 SEC. 104.2.2 CITY AMENDMENTS TO SBC/97
 AND SEC. 1603 SBC 1997.
 4-SPECIFY CEILING INSTALLATION AT FRONT
 AND BACK PORCH. SPECIFY ALL FASTENERS.
 SEE ASTM C-1063.
 SEC. 2504.2 SBC 1997.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2002-02-12 Cont ID  
Sent By jgomez Date 2002-02-12 Time 18:52 Rev Time 2.50
Received By jgomez Date 2002-02-12 Time 18:52 Sent To  
Notes
2002-02-12 00:00:00CHECKLIST:
 1-REVISED ENERGY CALCULATIONS ARE WRONG
 AGAIN. SEE SQUARE FOOTAGES ENTERED FOR
 A/C AREA AND UNDER ATTIC AREA.
 -PROVIDE CORRECT UNDER ATTIC AREA AS
 REQUIRED BY SEC. 604.1.A.1 OF FLORIDA
 ENERGY EFFICIENCY CODE. 1997 ED.
 -NOTE: THIS IS A MODEL HOUSE. PREVIOUS
 ENERGY CALCULATIONS WERE DONE TO WORST
 CASE SCENARIO. NOW, THIS ONE IS NOT.
 CLARIFY IF USING WORST CASE SCENARIO
 OR IF ENERGY CALCULATIONS WILL BE
 CALCULATED FOR EACH HOUSE.
 2-PLANS SUBMITTED AT TIME OF APPLICATION
 SHOW GARAGE AT RIGHT HAND SIDE. NOW,
 PLANS RESUBMITTED SHOW GARAGE AT LEFT
 HAND SIDE. PROVIDE REVISED SURVEY FOR
 ZONING AND BUILDING RE-REVIEW.
 3-SPECIFY ON FLOOR PLAN 1 HR FIRE RATED
 GLASS BLOCK ASSEMBLY AT ZERO LOT LINE
 WALL AND REVISE GLASS BLOCK DETAILS ON
 SHEET 5 TO MATCH 1 HR ASSEMBLY AS PER
 UL LISTING. SEE ATTACHED COPY THAT WAS
 SUBMITTED BY CONTRACTOR.
 4-TRUSS DRAWINGS:
 A)TRUSS ENGINEER TO SIGN, SEAL AND DATE
 TRUSS LAYOUT.
 B)UPDATE GENERAL DETAILS AS REQUIRED.
 USE CURRENT CODES AND CORRECT MPH
 WIND LOAD.
 C)THERE ARE 2 ENGINEER'S SEALS ON
 GENERAL DETAILS. REVISE AS REQUIRED.
 D)GENERAL DETAILS ARE NOT LEGIBLE.
 E)SPECIFY ON ENGINEERED TRUSSES WHAT
 EDITION OF SBC WAS USED FOR DESIGN.
 IT SHALL BE SBC 1997.
 F)MIXING AND MATCHING ASCE 7-98 AND SBC
 1997 IS NOT ALLOWED. REVISE AS REQ'D.
 G)RIGHT WIND ZONE USING ASCE 7-98 IS
 140 MPH. REVISE AS REQUIRED.
 5-SPECIFY CEILING INSTALLATION AT FRONT
 AND BACK PORCH. SEE ASTM C-926 AND
 ASTM C-1063 AND PROVIDE SPECS AS REQ'D
 (SEC. 2504.2 SBC 1997).
 6-SEE COMMENTS ON PLANS.
 7-CLEARLY SPECIFY SIZE OF ANCHOR ON DWG
 3B. EG: HETA 16, 20 OR 24 ETC.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status   Date 2002-02-12 Cont ID  
Sent By jgomez Date 2001-11-28 Time 18:27 Rev Time 2.50
Received By jgomez Date 2001-11-28 Time 18:26 Sent To  
Notes
2001-11-28 00:00:00APPROVED WITH PROVISO:
 1-FLOOD ZONE AO: NEED TO PROVIDE THE
 ELEVATION CERTIFICATE.
 2-REVISE ENERGY CALCULATIONS:
 -UNDER ATTIC AREA IS INCORRECT. SEE
 SECTION 604.1.A.1 OF FLORIDA ENERGY
 EFFICIENCE CODE FOR BUILDING CONSTR.
 3-PROVIDE CURRENT UL ASSEMBLY # FOR
 FIRE RATED GLASS BLOCK ASSEMBLY.
 4-PROVIDE UPDATED PRODUCT APPROVAL FOR
 ENTRY DOORS.
 5-PROVIDE STRUCTURAL HANGING DETAIL FOR
 AHU. SPECIFY ALL CONNECTORS.
 SEC. 104.2.2 CITY AMENDMENTS TO SBC/97
 6-REVISE WINDOW SIZE FOR BEDROOM #3.
 24 SH WINDOW DOESN'T MEET THE MINIMUM
 CLEAR HT. OPENING OF 24". SEC 1005.4
 7-SPECIFY SAFETY GLASS WHERE REQUIRED.
 SEE PLANS.
 8-TRUSS DRAWINGS:
 -UPDATE GENERAL DETAILS. USE ASCE 7-95
 FOR 140MPH OR SBC 1997 FOR 110MPH.
 -MAKE SURE ALL DETAILS ARE LEGIBLE.
 -REVIEW STAMP BY ENGINEER OF RECORD
 DOESN'T IDENTIFY THE FIRM WHO REVIEWED
 THE TRUSS DRAWINGS.
 NOTE: ENGINEER DOESN'T NEED TO SEAL
 THE TRUSS LAYOUT. ONLY REVIEW
 AKNOWLEDGMENT IS REQUIRED.
 9-SOIL TEST REPORT ENGINEER TO PROVIDE
 ORIGINAL SIGNATURE, NOT RUBBER STAMP,
 AS REQUIRED BY CHAPTER 471 FL STATUTES
 10-TYPICAL WALL SECTION: REVISE ROOF
 SHEATHING SPECS. SEE SECTION 2306 OF
 CITY AMENDMENTS TO SBC FOR MINIMUM
 NAILING AND SPACING.

Review Stop Z ZONING
Rev No 1 Status P Date 2001-11-02 Cont ID  
Sent By sgraham Date 2001-11-02 Time 11:19 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***