Plan Review Details - Permit 01101423
Plan Review Stops For Permit 01101423
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-11-14 Cont ID  
Sent By dpalmer Date 2001-11-14 Time 15:30 Rev Time 0.00
Received By dpalmer Date 2001-11-14 Time 15:30 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2001-12-12 Cont ID  
Sent By pkrauss Date 2001-12-12 Time 13:20 Rev Time 0.10
Received By pkrauss Date   Time   Sent To  
Notes
2001-12-12 00:00:00MECHANICAL PERMIT 01120625..APOLLO AIR.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2001-11-10 Cont ID  
Sent By hmoser Date 2001-11-10 Time 12:17 Rev Time 0.33
Received By hmoser Date 2001-11-10 Time 12:17 Sent To  
Notes
2001-11-10 00:00:00NO MECHANICAL PERMIT NUMBER ON THIS
 APPLICATION11/10/01H.M.

Review Stop P PLUMBING
Rev No 1 Status P Date 2001-11-08 Cont ID  
Sent By jleech Date 2001-11-08 Time 17:48 Rev Time 0.33
Received By jleech Date 2001-11-08 Time 17:48 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 5 Status P Date 2002-02-28 Cont ID  
Sent By jgomez Date 2002-02-28 Time 14:23 Rev Time 0.25
Received By jgomez Date 2002-02-28 Time 14:23 Sent To  
Notes
2002-02-28 00:00:00DOOR PRODUCT APPROVAL.

Review Stop R ROOF PLAN REVIEW
Rev No 4 Status P Date 2002-02-23 Cont ID  
Sent By jgomez Date 2002-02-23 Time 17:02 Rev Time 0.33
Received By jgomez Date 2002-02-23 Time 17:02 Sent To  
Notes
2002-02-23 00:00:00TRUSS DRAWINGS AND REVISED DWG.

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status F Date 2002-01-19 Cont ID  
Sent By jgomez Date 2002-01-19 Time 14:53 Rev Time 1.30
Received By jgomez Date 2002-01-19 Time 14:53 Sent To  
Notes
2002-01-19 00:00:00SUBMITTAL CHECKLIST:
 1-PROVIDE REVISED ENERGY CALCULATIONS.
 THEY ARE REQUIRED FOR BUILDING PLAN
 REVIEW ALSO. NOT ONLY FOR MECH. REVIEW
 2-PROVIDE PRODUCT APPROVAL FOR ENTRY
 DOORS. PRODUCT APPROVAL SUBMITTED IS
 GOOD FOR WOOD FRAMED BUILDINGS ONLY,
 NOT FOR MASONRY CONSTRUCTION. SEE
 PRODUCT APPROVAL.
 -PROVIDE PRODUCT APPROVAL WITH LEGIBLE
 DRAWINGS AS WELL.
 3-TRUSS DRAWINGS 2ND REVIEW:
 A)THERE ARE SEVERAL CODES MIXED IN THE
 TRUSS DRAWINGS: SFBC, ASCE 7-98 AND
 SBC 1997. REVISE AS REQUIRED.
 B)ENGINEERED TRUSSES AREN'T FOLLOWING
 NOTE SPECIFIED BY ENGINEER OF RECORD
 ON SHEET 3A REGARDING 3 1/2" MINIMUM
 BEARING AT MID POINT OF TRUSS. SEE
 NOTE ON FRAMING PLAN AT REAR PORCH.
 C)ENGINEERED TRUSSES CALL FOR 14 FT
 ABOVE GROUND LEVEL. THIS APPLIES TO A
 FLAT ROOF. SLOPED ROOF IS DESIGNED
 ACCORDING TO THE MEAN ROOF HEIGHT,
 WHICH IN THIS CASE IS 15'. SEE DWGS
 BY DESIGNER OF RECORD AND REVISE AS
 REQUIRED.
 D)TRUSS LAYOUT USES ASCE 7-95. CLARIFY.
 4-ENGINEER OF RECORD TO SPECIFY
 CONNECTOR THAT RESIST THE UPLIFT LOADS
 CALCULATED FOR TRUSS HG3.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2001-12-05 Cont ID  
Sent By jgomez Date 2001-12-05 Time 17:48 Rev Time 0.25
Received By jgomez Date 2001-12-05 Time 17:48 Sent To  
Notes
2001-12-05 00:00:00RECEIVED REVISED SOIL TEST REPORT.
 APPROVED WITH PROVISO. SEE NOTES ON
 PREVIOUS REVIEW DATED 11-27-01.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status   Date   Cont ID  
Sent By jgomez Date 2001-11-27 Time 12:41 Rev Time 3.00
Received By jgomez Date 2001-11-27 Time 12:41 Sent To  
Notes
2001-11-27 00:00:00APPROVED WITH PROVISO:
 1-FLOOD ZONE AO. NEED ELEVATION
 CERTIFICATE.
 2-REVISE ENERGY CALCULATIONS. THERE IS
 NO EXTERIOR WOOD FRAME WALL. ALSO, SEE
 BEDRM DEFINITION & REVISE # OF BEDRMS.
 3-GLASS BLOCK INFORMATION IS TOO OLD.
 IT'S WRITTEN IN 1992. PROVIDE CURRENT
 UL ASSEMBLY SYSTEM.
 4-PROVIDE UPDATED PRODUCT APPROVAL FOR
 ENTRY DOORS.
 5-TRUSS DRAWINGS:
 A)UPDATE GENERAL DETAILS. USE SBC 1997
 FOR 110 MPH OR ASCE 7-95 FOR 140MPH.
 B)SOME GENERAL DETAILS ARE NOT LEGIBLE.
 C)IDENTIFY WHO REVIEW TRUSS DRAWINGS.
 ENGINEER OF RECORD DON'T NEED TO SEAL
 THIS DRAWING.
  
 6-TYPICAL WALL SECTION:
 -REVISE ROOF SHEATHING SPECS. SEE SEC.
 2306 OF CITY AMENDMENTS FOR MINIMUM
 NAIL SIZE AND SPACING ACCORDING TO
 THE ZONE.
 7-SOIL TEST ENGINEER TO PROVIDE ORIGINAL
 SIGNATURE AS REQUIRED BY CHAPTER 471
 OF FLORIDA STATUTES WHEN SUBMITTING
 DOCUMENTS FOR PUBLIC RECORDS.

Review Stop Z ZONING
Rev No 1 Status P Date 2001-10-30 Cont ID  
Sent By sgraham Date 2001-10-30 Time 13:38 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***