Plan Review Details - Permit 01101223
Plan Review Stops For Permit 01101223
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2002-01-24 Cont ID  
Sent By jwitmer Date 2002-01-24 Time 14:14 Rev Time 1.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2001-11-19 Cont ID  
Sent By jwitmer Date 2001-11-19 Time 08:17 Rev Time 1.25
Received By jwitmer Date 2001-11-19 Time 08:17 Sent To  
Notes
2001-11-19 00:00:00BUILDING PLAN REVIEW
 PERMIT # 01101223
 647 57TH STREET
 CONT: RITEWAY INSURANCE REPAIR
 CGC-048689
 TEL: (954) 923-3677
  
 SBC= 1997 STANDARD BUILDING CODE
 SBC*= AMENDMENTS/ STANDARD BUILDING CODE
  
 1)- FL. S.S. 489.113(3B)/(3G) STATE
 CONTRACTOR CAN NOT INSTALL ROOF SHINGLES
 ON A REMODEL, ONLY ON NEW ROOF.
  
 2)- MISSING ROOFING PRODUCT APPROVAL
 FOR ROOFING SYSTEM. SBCCI OR DADE COUNTY
 PRODUCT APPROVAL REQUIRED UNDER SEPERATE
 PERMIT WITH ASSOCIATED FEES.
  
 3)- SBC 1606.2.6.2COMPONENTS & CLADDING
 (2) COPIES OF PRODUCT APPROVALS WILL BE
 REQUIRED FOR ALL EXTERIOR OPENINGS,
 EITHER SBCCI OR DADE COUNTY PRODUCT
 APPROVAL REQUIRED;
 WINDOWS
 SWING DOORS
 GARAGE DOORS OVERHEAD OR ROLL UP
 SKYLIGHTS
 STORM SHUTTERS.
  
 3)- SBC 1005.4.1:EVERY SLEEPING ROOM
 ON THE FIRST FLOOR WILL REQUIRE EMERGEN-
 CY ESCAPE AND RESCUE OPENINGS, STATE
 SIZE.
  
 4)- SBC 1707.4: GLAZED OPENINNGS REQUIRE
 1.5 TIMES THE DESIGN PRESSURE, TEST
 REPORT FOR WIND, SEE ATTACHMENT.
  
 5)- SBC 1606.4.1*/ 1707.4.1* GLAZED
 OPENINGS WILL REQUIRE EITHER IMPACT
 RESISTANT GLAZING OR STORM SHUTTERS
 PASSING THE LARGE MISSLE IMPACT TESTING
 REQUIREMENTS, WITH CITY REQUIREMENTS
 KEY PLAACEMENT PLAN & INSTALLATION SCHED
 ULE, SEE ATTACHMENT.
  
 6)- SBC 1606.2.6.1 MAIN WIND FORCE RESIS
 TING SYSTEM. INDICATE WHAT TYPE OF
 FASTENERS ARE TO BE USED TO RESIST VERTI
 CAL AND HORIZONTAL WIND LOADS AND INDICA
 TE THE LOADS THAT EACH TYPE OF MECHANISM
 SHALL BE CAPABLE OF RESISTING.
  
 7)- CITY CODE 7.2 PERMIT FEES SHALL BE
 CALCULAETED USING THE STANDARD BUILDING
 CODE EVALUATION TABLES LATEST EDITION.
 832 SQ FT= $65345.00X .60 ( REMODEL)=
 $ 39,207.00 ADDITIONAL FEES DUE.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2002-03-22 Cont ID  
Sent By dpalmer Date 2002-03-22 Time 05:16 Rev Time 0.00
Received By dpalmer Date 2002-03-22 Time 05:16 Sent To  
Notes
2002-03-22 00:00:00************** PROVISO/REVISION ********
  
 THE FOLLOWING NEEDS TO BE REVISED ON
 PLANS BEFORE ANY FINAL ELECTRICAL
 INSPECTION IS CALLED IN.
 HAVE PLANS SUBMITTED FOR REVISION AND
 REVIEW. PAY REVISON FEE.
  
 1)NOTE: PLEASE SUBMIT AIC RATINGS FOR
 ALL NEW EQUIPMENT BEING INSTALLED.
 MAINS/PANELS/BREAKERS MUST BE RATED FOR
 THE AVAILABLE FAULT CURRENT PER 110-9.
  
 2) NOTE: PLEASE LIST THE REQ`D BATH(S)
 CIRCUIT(S) PER 210-11-C-3.
 MUST BE 20A AND #12AWG.
  
 3) PLEASE CLARIFY EQUIPMENT GROUNDING
 METHOD BETWEEN FIRST MEANS OF DISCONNECT
 AND PANEL(S). EQUIPMENT GROUNDING
 CONDUCTORS ARE TO BE SIZED BY 250-122.
  
 4)NOTE: PLEASE SHOW LOCATION OF SERVICE
  
 5)NOTE: PLEASE NOTE, DISCONNECT FOR
 A/C COND UNIT NEEDS TO BE SHOWN PER
 440-11.
  
 PLEASE SUBMIT ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 ETX 8372

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2002-01-29 Cont ID  
Sent By dpalmer Date 2002-01-29 Time 07:33 Rev Time 0.00
Received By dpalmer Date 2002-01-29 Time 07:33 Sent To  
Notes
2002-01-29 00:00:00**************** UNSAT ****************
  
 1)NOTE: PLEASE NOTE THAT NOTES FROM
 FIRST REVIEW WERE NOT ADDRESSED.
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION
 FOR REVIEW. PERMIT APPLICATIONSHOWS
 ALL NEW ELECTRICAL.
 IF THERE ARE ANY QUESTIONS, PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2001-10-23 Cont ID  
Sent By dpalmer Date 2001-10-23 Time 20:07 Rev Time 0.00
Received By dpalmer Date 2001-10-23 Time 20:07 Sent To  
Notes
2001-10-23 00:00:00******************* UNSAT ************
  
 1)NOTE: PLEASE NOTE THAT NO DIAGRAM
 WAS SUBMITTED FOR NEW SERVICE?? 215-5
 SIZES.WIRE,CONDUITS,GROUNDING ETC.
  
 2)NOTE: PLEASE SUBMIT AIC RATINGS FOR
 ALL NEW EQUIPMENT BEING INSTALLED.
 MAINS/PANELS/BREAKERS MUST BE RATED FOR
 THE AVAILABLE FAULT CURRENT PER 110-9.
  
 3) NOTE: PLEASE LIST THE REQ`D BATH(S)
 CIRCUIT(S) PER 210-11-C-3.
 MUST BE 20A AND #12AWG.
  
 4) NOTE: PLEASE SHOW ALL OUTLETS SERVING
 KITCHEN COUNTERSPACE AS GFI/GFI PROTECT-
 -ED PER 210-8-A-6.
  
 5) NOTE: SMOKE DETECTORS ARE REQUIRED
 INSIDE AND OUTSIDE ALL SLEEPING ROOMS.
 ALSO ON EACH LEVEL OF A MULTI-LEVEL
 DWELLING UNIT. ROOMS WITH BATHS AND OR
 CLOSETS ARE CONSIDERED SLEEPING ROOMS.
 PER NFPA-72 2-2.1.1.1.
  
 6)NOTE: PLEASE SUBMIT PLANS THAT ARE
 MORE CLEAR. PER 104.2.1 AND 104.2.7
 CLARITY OF PLANS
  
 7)NOTE: PLEASE NOTE THAT IF THERE IS
 GOING TO BE ANY LV TV,OR PHONE, PLEASE
 SHOW ON PLANS. OTHERWISE SEPARTE PLANS
 WILL HAVE TO BE SUBMITTED AT A LATER
 DATE.
  
 8))PLEASE NOTE EITHER MISSING EGRESS
 LIGHTING AND/OR CLARIFY EGRESS LIGHTING
 PER 210-70 OF THE NEC.
 PLEASE NOTE MISSING LIGHTING IN SOME
 LOCATIONS, SHOWN AS "JB" KITCHEN/PORCH/
 LAUNDRY RM/ BATH? ETC/
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2001-10-29 Cont ID  
Sent By pkrauss Date 2001-10-29 Time 08:23 Rev Time 0.30
Received By pkrauss Date 2001-10-29 Time 08:15 Sent To  
Notes
2001-10-29 00:00:00 
  
 NO MECHANCIAL PLANS SUBMITTED FOR
 REVIEW.PLEASE PROVIDE PLANS WITH
 MECHANICAL PERMIT APPLICATION.
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop P PLUMBING
Rev No 1 Status P Date 2001-10-26 Cont ID  
Sent By kstevens Date 2001-10-26 Time 18:51 Rev Time 0.50
Received By kstevens Date 2001-10-26 Time 18:51 Sent To  
Notes
2001-10-26 00:00:00PASSED/PROVISO
  
 PASS ON CONDITION OF FIELD INSPECTORS
 INSPECTION OF DWV AND WATER PIPING.
 PLUMBER TO CALL FOR MISCELLANIOUS INSP-
 ECTION WHEN WALLS ARE OPEN. TESTS TO
 EXISTING PIPING MAY BE REQUIRED.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT. 8377