Plan Review Stops For Permit 01101180 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
|
Time |
|
Sent To |
|
|
Notes |
2002-05-15 00:00:00 | REVISION #3 DATED 4/22/02 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2002-02-08 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2002-02-08 |
Time |
12:52 |
Rev Time |
2.50 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2002-02-08 00:00:00 | BUILDING REVISION OKJW |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2001-12-06 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2001-12-06 |
Time |
07:24 |
Rev Time |
0.75 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2001-11-05 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2001-11-05 |
Time |
10:27 |
Rev Time |
1.50 |
Received By |
jwitmer |
Date |
2001-11-05 |
Time |
10:27 |
Sent To |
|
|
Notes |
2001-11-05 00:00:00 | BUILDING PLAN REVIEW | | PERMIT # 01101180 | | 400 NORTHPOINT PARKWAY # 401 | | CONT: BUTTERS CONSTRUCTION | | TEL: (954) 570-8111 | | | | SBC= 1997 STANDARD BUILDING CODE | | SBC*= AMENDMENTS/ STANDARD BUILDING CODE | | | | 1)- SHEET A-4 (NOTE) CARD READER- PLEASE | | SUBMIT INFORMATION ON THE ELEC. LOCK ON | | MAIN ENTRY DOOR THAT WILL COMPLY WITH | | SECTION 1012.6.1 SBC., OR HOW DOOR WILL | | UNLOCK WHEN LOSS OF POWER? HOW WOULD | | FIRE DEPARTMENT GAIN ACCESS? SIGNAGE. | | | | 2)- SHEET A-4 ROOM # 116 INDICATES THAT | | FILES & SHELVING WILL BE PART OF THIS | | ROOM, INDICATE CLEAR FLOOR SPACE FOR | | REQUIRED MEANS OF EGRESS. | | | | 3)- SBC TABLE 803.3 PROVIDE THE MINIMUM | | INTERIOR FINISH SCHEDULE FOR BUSINESS | | OCCUPANCY/ SPRINKLERED. | | | | 4)- FL ACC CODE 4.5.1 FLOOR SURFACES | | ALONG ACCESSIBLE ROUTES AND IN ACCESS- | | IBLE ROOMS AND SPACES INCLUDING FLOORS, | | WALKS AND RAMPS SHALL BE FIRM AND SLIP | | RESISTANT. COMPLY WITH ADDAAG A4.5.1 | | A STATIC COEFFICIENT OF 0.6 IS RECOMMEND | | ED FOR ACCESSIBLE ROUTES SND 0.8 FOR | | RAMPS. | | | | BUILDING PLAN REVIEW | | JIM WITMER | | (561) 659-8096X8412 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2002-05-07 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-05-07 |
Time |
11:33 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2002-05-07 |
Time |
11:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2002-02-11 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-02-11 |
Time |
07:56 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2002-02-11 |
Time |
07:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2001-12-04 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2001-12-04 |
Time |
22:53 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2001-12-04 |
Time |
22:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2001-10-30 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2001-10-30 |
Time |
20:11 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2001-10-30 |
Time |
20:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2002-05-10 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2002-05-10 |
Time |
12:20 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2002-05-10 |
Time |
12:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2001-11-05 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2001-11-05 |
Time |
12:23 |
Rev Time |
0.05 |
Received By |
pkrauss |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-11-05 00:00:00 | OKAY PER CAPTAIN MIKE CARSILLO 10-22-01 | | SIGNED OFF ON PLAN. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
pkrauss |
Date |
2002-05-20 |
Time |
10:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2002-02-12 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2002-02-12 |
Time |
14:55 |
Rev Time |
1.00 |
Received By |
pkrauss |
Date |
2002-02-12 |
Time |
14:55 |
Sent To |
|
|
Notes |
2002-02-12 00:00:00 | PROVISO: | | | | | | PLAN SHEET M2.1 ROOM 115 - AS PER | | CONVERSATION WITH MIKE PELLA, THIS AREA | | IS FOR FUTURE. | | | | PLEASE NOTE | | | | REVISION REQUIRED SHOULD ROOM 115 | | BUILDOUT BE DETERMINED PRIOR TO | | FINAL.SEPARATE PERMIT REQUIRED | | SHOULD BUILD-OUT OF ROOM 115 OCCUR | | AFTER FINAL. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2001-12-07 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2001-12-07 |
Time |
16:57 |
Rev Time |
0.40 |
Received By |
pkrauss |
Date |
2001-12-07 |
Time |
16:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2001-11-05 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2001-11-05 |
Time |
11:55 |
Rev Time |
0.55 |
Received By |
pkrauss |
Date |
2001-11-05 |
Time |
11:35 |
Sent To |
|
|
Notes |
2001-11-05 00:00:00 | ********************DENIED************** | | | | | | PLEASE PROVIDE AIR BALANCE SCHEDULE | | SHOWING COMPLIANCE WITH 1997 SMC 501.2. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT 659-8096 | | EXT. 8388. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2002-02-11 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2002-02-11 |
Time |
18:43 |
Rev Time |
0.75 |
Received By |
kstevens |
Date |
2002-02-11 |
Time |
18:43 |
Sent To |
|
|
Notes |
2002-02-11 00:00:00 | REVISION OK - REMOVE INSTA-HOTKS |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2001-12-03 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2001-12-03 |
Time |
18:39 |
Rev Time |
1.00 |
Received By |
kstevens |
Date |
2001-12-03 |
Time |
18:39 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2001-10-30 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2001-10-30 |
Time |
18:47 |
Rev Time |
1.25 |
Received By |
kstevens |
Date |
2001-10-30 |
Time |
18:47 |
Sent To |
|
|
Notes |
2001-10-30 00:00:00 | DENIED | | REFERENCE: SPC-94 - FACBC-97 | | | | 1) PLEASE PROVIDE MINIMUM FIXTURE CALCU- | | LATIONS. SHOW GROSS SQUARE FOOTAGE AND | | NET SQUARE FOOTAGE. SHOW USAGE OF BLDG. | | 2) PAGE A5.1 DETAILS 2 & 3, REMOVABLE | | PIPE GUARD NOT APPROVED FOR BREAK ROOM | | SINK. SINK SHALL COMPLY WITH FACBC SEC | | 4.24.3 27" HIGH/30"WIDE/ & 19" DEEP. | | 3) PAGE PO.1 DOMESTIC WATER ISOMETRIC, | | WATER HAMMER ARRESTORS SHALL BE PLACED | | NEAR FIXTURES NOT ON TOP OF DROP AS | | SHOWN. | | 4) PAGE PO.1 PLUMBING NOTES #13, AIR | | CHAMBERS ARE QUICK FIX AND IF USED SHALL | | COMPLY WITH SPC SEC 607.8.3 AND BE | | ACCESSIBLE AND RECHARGEABLE PER WH-PDI | | 201. | | | | REVIEW BY KEN STEVENS | | (561) 659-8096 EXT. 8377 |
|
|