Plan Review Stops For Permit 01100577 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2001-11-26 |
|
|
Cont ID |
|
Sent By |
lsmith |
Date |
2001-11-13 |
Time |
07:13 |
Rev Time |
0.75 |
Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-11-13 00:00:00 | SEE PLUMB & ELEC NOTES LS |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
N |
Date |
2001-11-20 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2001-11-20 |
Time |
17:21 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2001-11-20 |
Time |
17:21 |
Sent To |
P |
|
Notes |
2001-11-20 00:00:00 | *** NOTE*** | | PLANS MENTION THAT SPA IS FUTURE. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2001-11-02 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2001-11-02 |
Time |
05:59 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2001-11-02 |
Time |
05:59 |
Sent To |
|
|
Notes |
2001-11-02 00:00:00 | **************** UNSAT *************** | | | | 1)NOTE: PLEASE NOTE THAT WIRING DIAGRAM | | FOR SPA UNIT IS NOT ENOUGH. | | AS ASK FOR ON FIRST REVIEW, DEPENDING | | ON SIZE OF UNIT? | | PLEASE NOTE THAT UNIT IS SHOWN AS 50A OR | | 60A? WHICH ONE? PLEASE NOTE THAT NO | | LOAD CALCULATIONS WERE SUBMITTED? SIZE | | OF EXISTING SERVICE? | | PLEASE NOTE THAT PLANS STILL NEED TO | | SHOW WIRING TO UNIT,WIRE SIZE, CONDUIT, | | GROUNDING.. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2001-10-18 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2001-10-18 |
Time |
10:32 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2001-10-18 |
Time |
10:32 |
Sent To |
|
|
Notes |
2001-10-18 00:00:00 | ************** UNSAT ****************** | | | | 1)NOTE: PLEASE NOTE THAT "PLANS" SAY | | 220V HOOK UP????PLEASE CLARIFY. | | PLEASE ALSO NOTE THAT NOT ENOUGH | | INFORMATION WAS SUBMITTED FOR REVIEW/. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
N |
Date |
2001-11-26 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2001-11-26 |
Time |
10:09 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2001-11-26 |
Time |
10:09 |
Sent To |
|
|
Notes |
2001-11-26 00:00:00 | NO PLUMING | | APPLICATION MENTIONS FUTURE PORTABLE SPA |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2001-11-10 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2001-11-20 |
Time |
17:21 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2001-11-10 |
Time |
07:52 |
Sent To |
|
|
Notes |
2001-11-10 00:00:00 | DENIED | | REFERENCE: SPC-94 - UNIFORM COUNTYWIDE | | SWIMMING POOL AND | | SPA CODE. | | | | 1) PLEASE PROVIDE A LISTING FOR THE SPA. | | SPC 104.2.1 AND 104.3.2 | | | | 2) PLEASE PROVIDE A COMPLETE SET OF MAN- | | UFACTURE SPECS FOR ALL SYSTEMS FOR THE | | SPA. UCSPSC SEC 3 (C) (D) (E) (F) | | | | REVIEW BY KEN STEVENS | | (561) 659-8096 EXT 8377 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2001-10-15 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2001-10-15 |
Time |
10:44 |
Rev Time |
0.33 |
Received By |
kstevens |
Date |
2001-10-15 |
Time |
10:44 |
Sent To |
|
|
Notes |
2001-10-15 00:00:00 | DENIED | | | | 1) NOT ENOUGH INFORMATION. PLEASE SUBMIT | | WITH PLANS A PIPING DIAGRAM SHOWING ALL | | PIPE SIZES, FOR MAIN DRAIN AND RETURN | | LINES AND BLOWER LINES OR ANY OTHER | | PIPING FROM EQUIPMENT PAD TO SPA. | | | | 2) PLEASE SHOW WHERE POO/SPA EQUIPMENT | | SHALL BE LOCATED AND SHOW PUMP, FILTER | | AND ANY OTHER EQUIPMENT ASSOCIATED WITH | | SPA. | | | | REVIEW BY KEN STEVENS | | (561) 659-8096 EXT. 8377 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2001-10-09 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2001-10-09 |
Time |
14:56 |
Rev Time |
0.25 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|