Plan Review Details - Permit 01100393
Plan Review Stops For Permit 01100393
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2001-10-15 Cont ID  
Sent By lsmith Date 2001-10-15 Time 09:44 Rev Time 0.50
Received By lsmith Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2001-11-09 Cont ID  
Sent By dpalmer Date 2001-11-09 Time 07:00 Rev Time 0.00
Received By dpalmer Date 2001-11-09 Time 07:00 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2001-10-23 Cont ID  
Sent By dpalmer Date 2001-10-23 Time 19:51 Rev Time 0.00
Received By dpalmer Date 2001-10-23 Time 19:51 Sent To  
Notes
2001-10-23 00:00:00************** UNSAT ******************
  
 1)NOTE: PLEASE NOTE THAT NOTE COMING
 BACK SAYS HEAT PUMP IS BEING REMOVED
 FROM PERMIT APPLICATION? PLEASE CLARIFY
 SPEC SHEETS THAT WERE STILL SUBMITTED
 FOR HEAT PUMP.
  
 2)NOTE: PLEASE NOTE THAT CONTRACT THAT
 WAS SUBMITTED TO VERIFY VALUE STILL
 SHOWS HEAT PUMP IN CONTRACT WITH THE
 CUSTOMER? PLEASE CLARIFY.
  
 PLEASE NOTE THAT ANY CHANGES TO SIGNED
 AND SEALED ENGINEERED DRAWINGS HAVE TO
 BE DONE BY THE ENG OF RECORD. PER FS/
 FAC. 471.025
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2001-10-11 Cont ID  
Sent By dpalmer Date 2001-10-11 Time 12:26 Rev Time 0.00
Received By dpalmer Date 2001-10-11 Time 12:26 Sent To  
Notes
2001-10-11 00:00:00********* USNAT ***********
  
 1)NOTE:PLEASE NOTE THAT HEAT PUMP IS
 NOT INCLUDED IN WIRING DIAGRAM.
 PLEASE SHOW
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop P PLUMBING
Rev No 3 Status N Date 2001-11-09 Cont ID  
Sent By dpalmer Date 2001-11-09 Time 07:00 Rev Time 0.00
Received By lsmith Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2001-10-27 Cont ID  
Sent By kstevens Date 2001-10-27 Time 10:46 Rev Time 0.33
Received By kstevens Date 2001-10-27 Time 10:46 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2001-10-10 Cont ID  
Sent By kstevens Date 2001-10-10 Time 13:27 Rev Time 0.33
Received By kstevens Date 2001-10-10 Time 13:27 Sent To  
Notes
2001-10-10 00:00:00DENIED
  
 REFERENCE: UNIFORM COUNTYWIDE SWIMMING
 POOL AND SPA CODE.
  
 NOTE FILTER AND PIPING ISOMETRIC SHOWS
 2 RETURNS TO POOL. SEC 36(E) REQUIRES
 THAT A MINIMUM OF 3 RETURNS SHALL BE
 PROVIDED TO EACH POOL. PLEASE SHOW THE
 CORRECT NUMBER OF RETURNS.
  
 REVIEW BY KEN STEVENS
 (561) 569-8096 EXT. 8377

Review Stop Z ZONING
Rev No 1 Status P Date 2001-10-05 Cont ID  
Sent By sgraham Date 2001-10-05 Time 11:46 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***