Plan Review Details - Permit 01100285
Plan Review Stops For Permit 01100285 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2001-10-25 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2001-10-25 |
Time |
13:02 |
Rev Time |
1.50 |
Received By |
jwitmer |
Date |
2001-10-25 |
Time |
13:02 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2001-11-07 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2001-11-07 |
Time |
21:48 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2001-11-07 |
Time |
21:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2001-10-24 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2001-10-24 |
Time |
19:54 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2001-10-24 |
Time |
19:54 |
Sent To |
|
|
Notes |
2001-10-24 00:00:00 | ******************* UNSAT *********** | | | | 1)NOTE: PLEASE CLARIFY OCP FOR "EXISTING | | "DS-2 FEEDING NEW '2M'. PLEASE NOTE | | PLANS DO NOT SHOW SIZE. | | | | 2)NOTE: PLEASE SHOW LOAD CALCULATIONS, | | PLEASE SHOW ALL CONTINUOUS LOADS AT | | 125%. PLEASE NOTE THAT LOADS ARE SHOWN | | AT CONNECTED/AMPS/DEMAND? NEED TO SHOW | | WATTS/SQ FT/OUTLETS LOADS. ?= 180VA. | | PLEASE NOTE THAT LOAD SHOWN FOR OUTELTS | | IS AT 13.1KW, PLEASE NOTE BY ROUGH | | COUNT IT APPEARS TO BE HIGHER? | | PLEASE CLARIFY BY SHOWING. | | LARGEST MOTOR AT 125% ALSO. | | 215-5. 215-2,230-42,,,,, | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW, IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2001-10-17 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2001-10-17 |
Time |
12:14 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2001-10-17 |
Time |
12:14 |
Sent To |
|
|
Notes |
2001-10-17 00:00:00 | IF OCCUPANT LOAD IS GREATER THAN 50 | | PERSONS THEN THE DOUBLE DOORS FROM | | VESTIBULE 200 MUST SWING IN THE | | DIRECTION OF EXIT TRAVEL. | | | | APPROVED PROVISO: | | | | MIKE CARSILLO, CAPTAIN | | 659-8096,EXT.8497 | | 835-2910 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2001-11-21 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2001-11-21 |
Time |
16:19 |
Rev Time |
0.35 |
Received By |
pkrauss |
Date |
2001-11-21 |
Time |
16:17 |
Sent To |
|
|
Notes |
2001-11-21 00:00:00 | REVISION ON PLAN SHEET M-4 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2001-10-18 |
|
|
Cont ID |
|
Sent By |
ndenmark |
Date |
2001-10-18 |
Time |
10:34 |
Rev Time |
0.33 |
Received By |
ndenmark |
Date |
2001-10-18 |
Time |
10:34 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2001-12-15 |
|
|
Cont ID |
|
Sent By |
pschmitz |
Date |
2001-12-15 |
Time |
15:48 |
Rev Time |
0.50 |
Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-12-15 00:00:00 | A/C CONDENSATE DRY WELLS, |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2001-11-16 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2001-11-16 |
Time |
10:58 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2001-11-16 |
Time |
10:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2001-10-21 |
|
|
Cont ID |
|
Sent By |
pschmitz |
Date |
2001-10-21 |
Time |
14:51 |
Rev Time |
25.00 |
Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-10-21 00:00:00 | PLUMBING PLAN REVIEW,DENIED | | (1) SHT A1,MINIMUM FACILITIES, TAB 407 | | REQUIRES 3 W/C'S AND 3 LAVS, IN RM 210 | | WOMENS REST RM. | | (2)SHT A-1-5, BREAK SINK, RM 219, COMPLY | | WITH FACBC-97 SEC 4.24, HGTH 34" AFF. | | (3)SHT P1 SPECIFICATIONS, LIST MATERIALS | | FOR DWV AND WATER PIPING, SEC 104.2 | | END OF COMMENTSPAUL SCHMITZ | | QUESTIONS561-659-8096X8233 |
|
|
|