Plan Review Details - Permit 01091708
Plan Review Stops For Permit 01091708
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2002-01-07 Cont ID  
Sent By jgomez Date 2002-01-07 Time 12:15 Rev Time 0.25
Received By jgomez Date 2002-01-07 Time 12:15 Sent To  
Notes
2002-01-07 00:00:00PRODUCT APPROVAL CHECKLIST:
 1-FRENCH DOOR SITE SPECIFIC PRODUCT
 APPROVAL:
 A)MANUFACTURER'S ENGINEER TO PROVIDE
 ORIGINAL SIGNATURE AND OFFICE ADDRESS
 & PHONE NUMBER AS REQUIRED BY CHAPTER
 471 FLORIDA STATUTES WHEN SUBMITTING
 DOCUMENTS FOR PUBLIC RECORDS.
 B)USE CITY SAMPLE (ATTACHED) WHEN
 SUBMITTING INFORMATION FOR SITE
 SPECIFIC PRODUCT APPROVAL.
 C)PROFESSIONAL ENGINEER OF RECORD NEED
 TO SIGN, SEAL & DATE THIS SPECIFIC
 PRODUCT APPROVAL FORM AS WELL.
 -INCLUDE ALL HIS INFORMATION AS REQ'D
 BY CHAPTER 471 FLORIDA STATUTES.
 -SPECIFY LOCATION. THIS IS A SITE
 SPECIFIC INSTALLATION.
 D)CLARIFY WHY THE 2X WOOD BUCK IS NOT
 STRUCTURAL. SEE SECTION 4.2 OF PRODUCT
 APPROVAL INFORMATION SUBMITTED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2001-12-07 Cont ID  
Sent By jgomez Date 2001-12-07 Time 14:04 Rev Time 0.50
Received By jgomez Date 2001-12-07 Time 14:04 Sent To  
Notes
2001-12-07 00:00:00APPROVED WITH PROVISO:
 1-FLOOD ZONE AO. NEED THE ELEVATION
 CERTIFICATE.
 2-NEED ADDITIONAL SOIL BORINGS FOR EACH
 STRUCTURE AS RECOMMENDED ON THE PRE-
 LIMINARY SOIL TEST REPORT.
 3-PROVIDE PRODUCT APPROVAL FOR FRENCH
 DOORS ASSEMBLIES AS SHOWN ON PLANS IF
 OPTION IS SELECTED.
 4-PROVIDE MANUFACTURER'S CERTIFICATION
 FOR TWO HOUR FIRE RATED CONCRETE BLOCK
 ACCORDING TO THE BLOCK'S EQUIVALENT
 THICKNESS AND AGGREGATES USED. SEE
 SECTION 709.3 SBC 1997.
 5-PROVIDE COMPLETE INFORMATION FOR STORM
 PANELS UNDER A SEPARATE PERMIT.
  
  
 NOTES:
 -DRAWINGS AND COMMENTS TO BE FILED UNDER
 PERMIT #01091708.
 -THESE COMMENTS APPLY TO PERMIT #S:
 01091708, 01091723, 01091730 AND
 01091719.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2001-11-07 Cont ID  
Sent By jgomez Date 2001-11-07 Time 13:11 Rev Time 1.00
Received By jgomez Date 2001-11-07 Time 13:11 Sent To  
Notes
2001-11-07 00:00:00CHECKLIST:
 1-SEE COMMENTS BY PLUMBING. REVISE
 ORIGINAL DRAWINGS TO AVOID DELAYS AND
 ADDITIONAL FEES.
 2-NEED TO RECORD N.O.C.
 3-NEED ADDITIONAL SOIL BORINGS FOR EACH
 STRUCTURE AS RECOMMENDED ON THE PRE-
 LIMINARY SOIL TEST REPORT.
 4-PROVIDE PRODUCT APPROVAL FOR:
 -GARAGE DOOR PRODUCT APPROVAL WAS
 DELETED BY SBCCI.
 -WINDOW MULLIONS.
 5-CLEARLY INDICATE ON PLANS OPTIONS TO
 BE BUILT AND PROVIDE PRODUCT APPROVAL
 OR DELETE OPTIONS.
 6-OWES ADDITIONAL FEES. PLEASE BRING
 BACK PAID RECEIPTS.
 7-PROVIDE MANUFACTURER'S CERTIFICATION
 FOR 2 HOUR FIRE RATED CONCRETE BLOCK
 SPECIFYING HOW IT COMPLIES WITH SEC.
 709.3 SBC 1997 ACCORDING TO THE
 EQUIVALENT THICKNESS AND AGGREGATES
 USED.
 8-PROVIDE COMPLETE INFORMATION FOR STORM
 SHUTTERS OR APPLY FOR SEPARATE PERMIT.
  
  
  
 NOTES:
 -DRAWINGS TO BE FILED UNDER PERMIT #
 01091708.
 -THESE COMMENTS APPLY TO PERMIT #S:
 01091708, 01091723, 01091730 AND
 01091719.
2001-11-06 00:00:00CHECKLIST:
 1-SEE COMMENTS BY PLUMBING. REVISE
 ORIGINAL DRAWINGS TO AVOID DELAYS AND
 ADDITIONAL FEES.
 2-NEED TO RECORD NOTICE OF COMMENCEMENT.
 3-

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-09-23 Cont ID  
Sent By btrobaug Date 2002-09-23 Time 09:17 Rev Time 0.25
Received By btrobaug Date 2002-09-23 Time 08:25 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-10-23 Cont ID  
Sent By dpalmer Date 2001-10-23 Time 22:19 Rev Time 0.00
Received By dpalmer Date 2001-10-23 Time 22:19 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2001-12-06 Cont ID  
Sent By mcarsill Date 2001-12-06 Time 15:42 Rev Time 0.00
Received By mcarsill Date 2001-12-06 Time 15:42 Sent To  
Notes
2001-12-06 00:00:001) WET FIRE HYDRANTS ARE REQUIRED PRIOR
 TO,DURING AND AFTER CONSTRUCTION.
 2) BUILDING ADDRESSES REQUIRED.
 3) PORTABLE FIRE EXTINGUISHERS REQUIRED.
 4) ELECTRIC POWERED SMOKE DETECTORS
 REQUIRED.
 5) EGRESS WINDOWS TO COMPLY WITH
 BUILDING AND FIRE CODE REGULATIONS.
  
 MIKE CARSILLO, CAPTAIN
 659-8096,EXT.8497
 835-2910

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-01-29 Cont ID  
Sent By pkrauss Date 2002-01-29 Time 16:24 Rev Time 0.30
Received By pkrauss Date 2002-01-29 Time 16:15 Sent To  
Notes
2002-01-29 00:00:00MECH REV PERMIT 01091749

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2001-10-08 Cont ID  
Sent By hmoser Date 2001-10-08 Time 07:20 Rev Time 0.33
Received By hmoser Date 2001-10-08 Time 07:19 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2001-12-01 Cont ID  
Sent By kstevens Date 2001-12-01 Time 06:46 Rev Time 0.33
Received By kstevens Date 2001-12-01 Time 06:46 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2001-10-17 Cont ID  
Sent By jleech Date 2001-10-17 Time 18:35 Rev Time 0.00
Received By jleech Date   Time   Sent To  
Notes
2001-10-17 00:00:00SEE REVIEW NOTES UNDER P 01091719

Review Stop Z ZONING
Rev No 1 Status P Date 2001-10-02 Cont ID  
Sent By sgraham Date 2001-10-02 Time 14:50 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***