Plan Review Details - Permit 01091691
Plan Review Stops For Permit 01091691
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2002-03-29 Cont ID  
Sent By jgomez Date 2002-03-29 Time 14:00 Rev Time 0.33
Received By jgomez Date 2002-03-29 Time 14:00 Sent To  
Notes
2002-03-29 00:00:00PRODUCT APPROVALS AND TRUSS DRAWINGS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2001-12-24 Cont ID  
Sent By jgomez Date 2001-12-24 Time 14:21 Rev Time 1.00
Received By jgomez Date 2001-12-24 Time 14:21 Sent To  
Notes
2001-12-21 00:00:00APPROVED WITH PROVISO:
 1-FLOOD ZONE AO. NEED THE ELEVATION
 CERTIFICATE.
 2-NEED ADDITIONAL SOIL BORINGS FOR EACH
 STRUCTURE AS RECOMMENDED ON THE PRE-
 LIMINARY SOIL TEST REPORT.
 3-PRODUCT APPROVAL FOR SINGLE HUNG
 WINDOWS EXPIRED.
 -PROVIDE PRODUCT APPROVAL FOR FRENCH
 DOOR WITH SIDELITES IF OPTION SELECTED
 4-MASTER BEDROOM CAN'T HAVE OPTION OF
 DOORS AT REAR ELEVATION BECAUSE IT
 WILL NOT COMPLY WITH TABLE 600 SBC/97.
 ONLY SIDE DOOR OPTION WILL COMPLY.
 5-PROVIDE COMPLETE INFORMATION FOR STORM
 PANELS UNDER A SEPARATE PERMIT.
 6-TRUSS DRAWINGS:
 -UPDATE ALL GENERAL TRUSS DETAILS. USE
 ASCE 7-95 FOR 140MPH, NOT ASCE 7-93.
 SEE COMMENTS ON TRUSSES.
 -DESIGNER OF RECORD TO REVIEW ALL TRUSS
 DRAWINGS AND CLEARLY INDICATE WHO
 REVIEW THE TRUSSES. (NAME OF FIRM).
 7-PROVIDE MANUFACTURER'S CERTIFICATION
 FOR 2 HR FIRE RATED CONCRETE BLOCK
 ACCORDING TO THE EQUIVALENT THICKNESS
 AND AGGREGATES USED. SEE SECTION 709.3
 SBC 1997.
  
 NOTES:
 -DRAWINGS AND COMMENTS TO BE FILED UNDER
 PERMIT #01091691.
 -THESE COMMENTS APPLY TO PERMIT #S:
 01091691, 01091695, 01091697, 01091699
 01091701 AND 01091706.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2001-12-11 Cont ID  
Sent By jgomez Date 2001-12-11 Time 18:03 Rev Time 1.00
Received By jgomez Date 2001-12-11 Time 18:03 Sent To  
Notes
2001-12-11 00:00:00CHECKLIST:
 1-SEE COMMENTS BY PLUMBING. REVISE
 ORIGINAL DRAWINGS AS REQUIRED.
 2-NEED TO RECORD N.O.C.
 3-NEED ADDITIONAL SOIL BORINGS FOR EACH
 STRUCTURE AS RECOMMENDED ON THE PRE-
 LIMINARY SOIL TEST REPORT.
 4-PROVIDE PRODUCT APPROVAL FOR:
 -GARAGE DOOR PRODUCT APPROVAL WAS
 DELETED BY SBCCI.
 -WINDOW MULLIONS.
 5-CLEARLY INDICATE ON PLANS OPTIONS TO
 BE BUILT AND PROVIDE REQUIRED PRODUCT
 APPROVALS.
 NOTE:
 DOORS OPTION AT EXTERIOR WALL OF MASTER
 BEDROOM WILL NOT COMPLY WITH TABLE 600
 OF SBC 1997. ONLY SIDE DOORS ARE ALLOWED
  
 6-OWES ADDITIONAL FEES. PLEASE BRING
 BACK PAID RECEIPTS.
 7-PROVIDE MANUFACTURER'S CERTIFICATION
 FOR TWO HOUR FIRE RATED CONCRETE BLOCK
 ACCORDING TO THE EQUIVALENT THICKNESS
 AND AGGREGATES USED. SEE SECTION
 709.3 SBC 1997.
 8-PROVIDE COMPLETE INFORMATION FOR STORM
 SHUTTERS OR APPLY FOR SEPARATE PERMIT.
  
  
 NOTES:
 -DRAWINGS AND COMMENTS TO BE FILED UNDER
 PERMIT #01091691.
 -THESE COMMENTS APPLY TO PERMIT #S:
 01091691, 01091695, 01091697, 01091699,
 01091701 AND 01091706.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-10-09 Cont ID  
Sent By btrobaug Date 2002-10-09 Time 09:42 Rev Time 0.50
Received By btrobaug Date 2002-10-09 Time 09:37 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-11-30 Cont ID  
Sent By dpalmer Date 2001-11-30 Time 07:17 Rev Time 0.00
Received By dpalmer Date 2001-11-30 Time 07:17 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2001-12-06 Cont ID  
Sent By mcarsill Date 2001-12-06 Time 17:43 Rev Time 0.00
Received By mcarsill Date 2001-12-06 Time 17:43 Sent To  
Notes
2001-12-06 00:00:001) WET FIRE HYDRANTS ARE REQUIRED PRIOR
 TO,DURING AND AFTER CONSTRUCTION.
 2) BUILDING ADDRESS REQUIRED.
 3) PORTABLE FIRE EXTINGUISHER REQUIRED.
 4) ELECTRIC POWERED SMOKE DETECTORS
 REQUIRED.
 5) EGRESS WINDOWS TO COMPLY WITH
 BUILDING AND FIRE CODE REQUIREMENTS.
  
 MIKE CARSILLO, CAPTAIN
 659-8096,EXT.8497
 835-2910

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2001-11-29 Cont ID  
Sent By hmoser Date 2001-11-29 Time 18:25 Rev Time 0.33
Received By hmoser Date 2001-11-29 Time 18:25 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2001-12-21 Cont ID  
Sent By kstevens Date 2001-12-21 Time 11:52 Rev Time 1.50
Received By kstevens Date 2001-12-21 Time 11:52 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2001-11-20 Cont ID  
Sent By kstevens Date 2001-11-20 Time 18:20 Rev Time 0.50
Received By kstevens Date 2001-11-20 Time 18:20 Sent To  
Notes
2001-11-20 00:00:00DENIED
 REFERENCE: SPC -94-FACBC-97
  
 1) PAGES 1, 1A, & 1B. MODEL 1527(L)(R).
 M/BATH W/C TO BE 1'6" NOT 1'7" AS SHOWN
 ALSO SHOW CLEAR FLOOR SPACE FOR LAV.
 2) SHOW CLEAR FLOOR SPACE FOR LAV AND
 W/C IN 2ND BATH.
 3) PAGES 1, 1A, & 1B. MODEL 1409(L)(R).
 M/BATH W/C TO BE 1'6" NOT 1'7" AS SHOWN.
 ALSO SHOW CLEAR FLOOR SPACE FOR LAV.
 4) 2ND BATH MINIMUM OPENING FOR W/C IS
 2'9" NOT 2'8" AS SHOWN. ALSO SHOW CLEAR
 FLOOR SPACE FOR LAV AND W/C.
 5) PAGES 1, 1A, & 1B. MODEL 1357(L)(R).
 M/BATH W/C TO BE 1'6" NOT 1'7" AS SHOWN.
 ALSO SHOW CLEAR FLOOR SPACE FOR LAV.
 6) 2ND SHOW CLEAR FLOOR SPACE FOR W/C &
 LAV.
 7) PAGE 2, MODELS 1409(L)(R) & MODEL
 1527(L)(R) OPTIONAL LAUNDRY TRAYS NOT
 VENTED PROPERLY. PLEASE RESUBMIT RISER
 WITH PROPER VENTING.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop Z ZONING
Rev No 1 Status P Date 2001-11-14 Cont ID  
Sent By sgraham Date 2001-11-14 Time 11:15 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***