Plan Review Stops For Permit 01091691 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2002-03-29 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2002-03-29 |
Time |
14:00 |
Rev Time |
0.33 |
Received By |
jgomez |
Date |
2002-03-29 |
Time |
14:00 |
Sent To |
|
|
Notes |
2002-03-29 00:00:00 | PRODUCT APPROVALS AND TRUSS DRAWINGS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2001-12-24 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2001-12-24 |
Time |
14:21 |
Rev Time |
1.00 |
Received By |
jgomez |
Date |
2001-12-24 |
Time |
14:21 |
Sent To |
|
|
Notes |
2001-12-21 00:00:00 | APPROVED WITH PROVISO: | | 1-FLOOD ZONE AO. NEED THE ELEVATION | | CERTIFICATE. | | 2-NEED ADDITIONAL SOIL BORINGS FOR EACH | | STRUCTURE AS RECOMMENDED ON THE PRE- | | LIMINARY SOIL TEST REPORT. | | 3-PRODUCT APPROVAL FOR SINGLE HUNG | | WINDOWS EXPIRED. | | -PROVIDE PRODUCT APPROVAL FOR FRENCH | | DOOR WITH SIDELITES IF OPTION SELECTED | | 4-MASTER BEDROOM CAN'T HAVE OPTION OF | | DOORS AT REAR ELEVATION BECAUSE IT | | WILL NOT COMPLY WITH TABLE 600 SBC/97. | | ONLY SIDE DOOR OPTION WILL COMPLY. | | 5-PROVIDE COMPLETE INFORMATION FOR STORM | | PANELS UNDER A SEPARATE PERMIT. | | 6-TRUSS DRAWINGS: | | -UPDATE ALL GENERAL TRUSS DETAILS. USE | | ASCE 7-95 FOR 140MPH, NOT ASCE 7-93. | | SEE COMMENTS ON TRUSSES. | | -DESIGNER OF RECORD TO REVIEW ALL TRUSS | | DRAWINGS AND CLEARLY INDICATE WHO | | REVIEW THE TRUSSES. (NAME OF FIRM). | | 7-PROVIDE MANUFACTURER'S CERTIFICATION | | FOR 2 HR FIRE RATED CONCRETE BLOCK | | ACCORDING TO THE EQUIVALENT THICKNESS | | AND AGGREGATES USED. SEE SECTION 709.3 | | SBC 1997. | | | | NOTES: | | -DRAWINGS AND COMMENTS TO BE FILED UNDER | | PERMIT #01091691. | | -THESE COMMENTS APPLY TO PERMIT #S: | | 01091691, 01091695, 01091697, 01091699 | | 01091701 AND 01091706. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2001-12-11 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2001-12-11 |
Time |
18:03 |
Rev Time |
1.00 |
Received By |
jgomez |
Date |
2001-12-11 |
Time |
18:03 |
Sent To |
|
|
Notes |
2001-12-11 00:00:00 | CHECKLIST: | | 1-SEE COMMENTS BY PLUMBING. REVISE | | ORIGINAL DRAWINGS AS REQUIRED. | | 2-NEED TO RECORD N.O.C. | | 3-NEED ADDITIONAL SOIL BORINGS FOR EACH | | STRUCTURE AS RECOMMENDED ON THE PRE- | | LIMINARY SOIL TEST REPORT. | | 4-PROVIDE PRODUCT APPROVAL FOR: | | -GARAGE DOOR PRODUCT APPROVAL WAS | | DELETED BY SBCCI. | | -WINDOW MULLIONS. | | 5-CLEARLY INDICATE ON PLANS OPTIONS TO | | BE BUILT AND PROVIDE REQUIRED PRODUCT | | APPROVALS. | | NOTE: | | DOORS OPTION AT EXTERIOR WALL OF MASTER | | BEDROOM WILL NOT COMPLY WITH TABLE 600 | | OF SBC 1997. ONLY SIDE DOORS ARE ALLOWED | | | | 6-OWES ADDITIONAL FEES. PLEASE BRING | | BACK PAID RECEIPTS. | | 7-PROVIDE MANUFACTURER'S CERTIFICATION | | FOR TWO HOUR FIRE RATED CONCRETE BLOCK | | ACCORDING TO THE EQUIVALENT THICKNESS | | AND AGGREGATES USED. SEE SECTION | | 709.3 SBC 1997. | | 8-PROVIDE COMPLETE INFORMATION FOR STORM | | SHUTTERS OR APPLY FOR SEPARATE PERMIT. | | | | | | NOTES: | | -DRAWINGS AND COMMENTS TO BE FILED UNDER | | PERMIT #01091691. | | -THESE COMMENTS APPLY TO PERMIT #S: | | 01091691, 01091695, 01091697, 01091699, | | 01091701 AND 01091706. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2002-10-09 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2002-10-09 |
Time |
09:42 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2002-10-09 |
Time |
09:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2001-11-30 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2001-11-30 |
Time |
07:17 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2001-11-30 |
Time |
07:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2001-12-06 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2001-12-06 |
Time |
17:43 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2001-12-06 |
Time |
17:43 |
Sent To |
|
|
Notes |
2001-12-06 00:00:00 | 1) WET FIRE HYDRANTS ARE REQUIRED PRIOR | | TO,DURING AND AFTER CONSTRUCTION. | | 2) BUILDING ADDRESS REQUIRED. | | 3) PORTABLE FIRE EXTINGUISHER REQUIRED. | | 4) ELECTRIC POWERED SMOKE DETECTORS | | REQUIRED. | | 5) EGRESS WINDOWS TO COMPLY WITH | | BUILDING AND FIRE CODE REQUIREMENTS. | | | | MIKE CARSILLO, CAPTAIN | | 659-8096,EXT.8497 | | 835-2910 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2001-11-29 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2001-11-29 |
Time |
18:25 |
Rev Time |
0.33 |
Received By |
hmoser |
Date |
2001-11-29 |
Time |
18:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2001-12-21 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2001-12-21 |
Time |
11:52 |
Rev Time |
1.50 |
Received By |
kstevens |
Date |
2001-12-21 |
Time |
11:52 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2001-11-20 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2001-11-20 |
Time |
18:20 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2001-11-20 |
Time |
18:20 |
Sent To |
|
|
Notes |
2001-11-20 00:00:00 | DENIED | | REFERENCE: SPC -94-FACBC-97 | | | | 1) PAGES 1, 1A, & 1B. MODEL 1527(L)(R). | | M/BATH W/C TO BE 1'6" NOT 1'7" AS SHOWN | | ALSO SHOW CLEAR FLOOR SPACE FOR LAV. | | 2) SHOW CLEAR FLOOR SPACE FOR LAV AND | | W/C IN 2ND BATH. | | 3) PAGES 1, 1A, & 1B. MODEL 1409(L)(R). | | M/BATH W/C TO BE 1'6" NOT 1'7" AS SHOWN. | | ALSO SHOW CLEAR FLOOR SPACE FOR LAV. | | 4) 2ND BATH MINIMUM OPENING FOR W/C IS | | 2'9" NOT 2'8" AS SHOWN. ALSO SHOW CLEAR | | FLOOR SPACE FOR LAV AND W/C. | | 5) PAGES 1, 1A, & 1B. MODEL 1357(L)(R). | | M/BATH W/C TO BE 1'6" NOT 1'7" AS SHOWN. | | ALSO SHOW CLEAR FLOOR SPACE FOR LAV. | | 6) 2ND SHOW CLEAR FLOOR SPACE FOR W/C & | | LAV. | | 7) PAGE 2, MODELS 1409(L)(R) & MODEL | | 1527(L)(R) OPTIONAL LAUNDRY TRAYS NOT | | VENTED PROPERLY. PLEASE RESUBMIT RISER | | WITH PROPER VENTING. | | | | REVIEW BY KEN STEVENS | | (561) 659-8096 EXT 8377 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2001-11-14 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2001-11-14 |
Time |
11:15 |
Rev Time |
0.25 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|