Plan Review Details - Permit 01091672
Plan Review Stops For Permit 01091672
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2001-12-10 Cont ID  
Sent By jwitmer Date 2001-12-10 Time 13:11 Rev Time 0.50
Received By jwitmer Date 2001-12-10 Time 13:10 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2001-11-05 Cont ID  
Sent By jwitmer Date 2001-11-05 Time 17:42 Rev Time 2.50
Received By jwitmer Date   Time   Sent To  
Notes
2001-11-05 00:00:00BUILDING PLAN REVIEW
 PERMIT# 01091672
 1025 21 ST ST
 HABITAT FOR HUMANITY
 (561) 833-9665
  
 SBC= 1997 STANDARD BUILDING CODE
 SBC*= AMENDMENTS/STANDARD BUILDING CODE
  
 1)- PERMIT APPLICATION TO BE SIGNED BY
 THE PERSON WHICH WILL PROVIDE THE
 QUALIFIED SUPERVISION.
  
 2)- SBC* 104.2.2 A RECENT SURVEY. IF PRO
 PERTY IS LOCATED IN A "A" ZONE MINIMUM
 ELEVATION CERTIFICATE WILL BE REQUIRED.
 THIS LOT IS LOCATED IN A "B" ZONE.
  
 3)-SBC* 1804.2.7.2 SOILS REPORT/ W THE
 MINIMUM SAFE BEARING VALUE.
  
 4)- SBC 2304.1.2 SOIL TREATMENT FOR
 TERMITES FOR SLAB ON GRADE, TREATMENT OF
 SOIL REQUIRED BEFORE THE PLACEMENT OF
 CONCRETE.
  
 5)- SBC 1606.2.6.2 COMPONENTS & CLADDING
 PRODUCT APPROVAL REPORTS (2 COPIES)
 ARE REQUIRED FOR THESE ITEMS:
 A) GLAZED OPENINGS
 B) MULLIONS FOR WINDOWS
 C) EXTERIOR DOORS- MISSING
 D) ROOFING ASSEMBLIES-SHINGLES MISSING
 PRODUCT TESTING REPORT FOR 110 MPH
  
 6)- SHEET A-3 FRONT PORCH DETAIL, GAL.
 POST ANCHOR SIMPSON AB-44, ANCHOR BOLT
 MISSING INFORMATION. IS DERATING TO BE
 A FACTOR LESS THAN 2" FROM EDGE?
  
 7)- STORM SHUTTERS WPB INTERPRETATION
 REQUIRES A KEY PLAN & FASTENING SCHEDULE
 WITH THE PRODUCT APPROVAL REPORT SEE
 SAMPLE ATTACHED.
  
 8)- CALC VALUE:
 LIV. 1340 X 49.92=$66,892.80
 NON194 X 28.08= 5,447.52
 $72,340.32
 TOTAL CALC VALUE $72,340.00
  
 STATE RADON FEES $ 15.34
 ADDITIONAL PERMIT FEES $326.63
 JAN 1,2002 PLANS WILL BE REVIEWED UNDER
 THE 2001 FLORIDA BUILDING CODE FOR PLANS
 SUBMITTED AFTER THAT DATE.
  
  
 BUILDING PLAN REVIEW
 JIM WITMER
 (561) 659-8096 X8412

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-10-10 Cont ID  
Sent By dpalmer Date 2001-10-10 Time 09:23 Rev Time 0.00
Received By dpalmer Date 2001-10-10 Time 09:23 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2001-10-04 Cont ID  
Sent By hmoser Date 2001-10-04 Time 19:42 Rev Time 0.33
Received By hmoser Date 2001-10-04 Time 19:41 Sent To  
Notes
2001-10-04 00:00:00NO PERNIT# NO THIS APPLICATION H.M.

Review Stop P PLUMBING
Rev No 2 Status P Date 2001-12-09 Cont ID  
Sent By pschmitz Date 2001-12-09 Time 08:30 Rev Time 1.00
Received By pschmitz Date   Time   Sent To  
Notes
2001-12-09 00:00:00PROVISO, SEE ATTACHED PLBG ISOMETRIC.

Review Stop P PLUMBING
Rev No 1 Status F Date 2001-10-02 Cont ID  
Sent By jleech Date 2001-10-02 Time 19:48 Rev Time 0.33
Received By jleech Date 2001-10-02 Time 19:48 Sent To  
Notes
2001-10-02 00:00:00PLUMBING DENIED;
 RISER DIAGRAM NOT TO CODE.

Review Stop Z ZONING
Rev No 1 Status P Date 2001-10-02 Cont ID  
Sent By sgraham Date 2001-10-02 Time 14:54 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***