Plan Review Stops For Permit 01091542 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2003-06-02 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2003-06-02 |
Time |
17:38 |
Rev Time |
1.00 |
Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2003-06-02 00:00:00 | REVISION TO ADD SEAT IN SHOWER AND | | INTERIOR DOOR AT BED #2 AND BATH |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2002-03-29 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-06-02 |
Time |
16:27 |
Rev Time |
1.00 |
Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2003-05-07 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2003-05-07 |
Time |
14:01 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2003-05-07 |
Time |
14:00 |
Sent To |
|
|
Notes |
2003-05-07 00:00:00 | STEAM UNIT TO BE REMOVED PER CONTRACTOR. | | PLAN IS OK PENDING LETTER FROM ENGINEER | | OF RECORD. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW | | 561/805-6718 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2003-05-06 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2003-05-06 |
Time |
16:59 |
Rev Time |
1.00 |
Received By |
btrobaug |
Date |
2003-05-06 |
Time |
15:38 |
Sent To |
|
|
Notes |
2003-05-06 00:00:00 | UNSAT | | ~~~~~ | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | PLEASE NOTE THE LOCATION OF THE STEAM | | UNIT IN THE CLOSET IS IN VIOLATION OF | | 110-26(B),240-24(D) AND 422-17. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW | | 561/805-6718 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2002-03-29 |
|
|
Cont ID |
|
Sent By |
sthyng |
Date |
2003-04-28 |
Time |
11:43 |
Rev Time |
1.00 |
Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2002-03-29 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2002-03-29 |
Time |
15:02 |
Rev Time |
1.00 |
Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2003-06-02 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-06-02 |
Time |
16:27 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-06-02 |
Time |
16:27 |
Sent To |
B |
|
Notes |
2003-06-02 00:00:00 | LMARTINEZ DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-04-28 |
|
|
Cont ID |
|
Sent By |
sthyng |
Date |
2003-04-28 |
Time |
11:43 |
Rev Time |
0.00 |
Received By |
sthyng |
Date |
2003-04-28 |
Time |
11:43 |
Sent To |
E |
|
Notes |
2003-04-28 00:00:00 | TO ELEC IN BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-04-28 |
|
|
Cont ID |
|
Sent By |
sthyng |
Date |
2003-04-28 |
Time |
11:41 |
Rev Time |
0.00 |
Received By |
sthyng |
Date |
2003-04-28 |
Time |
11:41 |
Sent To |
P |
|
Notes |
2003-04-28 00:00:00 | TO PLUMB IN BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2002-03-29 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2002-03-29 |
Time |
15:02 |
Rev Time |
1.00 |
Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2003-04-29 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-04-29 |
Time |
11:35 |
Rev Time |
1.25 |
Received By |
kstevens |
Date |
2003-04-29 |
Time |
11:35 |
Sent To |
|
|
Notes |
2003-04-29 00:00:00 | DENIED | | REFERENCE:SPC-94 | | | | 1) CHANGES TO A SIGNED AND SEALED SET | | OF PLANS SHALL BE SIGNED AND SEALED BY | | ARCHITECT OR ENGINEER OF RECORD. | | 2) PER NEC-99SECTION 422.17 - EACH | | ELECTRICALLY HEATED APPLIANCE THAT IS | | INTENDED BY SIZE, WEIGHT, AND SERVICE TO | | BE IN A FIXED POSITION SHALL BE PLACED | | SO AS TO PROVIDE AMPLE PROTECTION BE- | | TWEEN THE APPLIANCE AND ADJACENT COMBUST | | IBLE MATERIAL. | | 3) PLEASE PROVIDE MANUF. INFO. FOR STEAM | | UNIT. UNIT SHALL BE LISTED BY A RECOG- | | NIZED TESTING ORGANIZATION . | | 4) ELECTRICAL REVISION REQUIRED ALSO. | | 6) PLEASE INDICATE WHERE THE BACKFLUSH | | LINE WILL BE DRAINING TO. | | 7) PLEASE INDICATE WHERE THE P/T RELEIF | | VALVE WILL DRAIN TO. | | | | REVIEW BY KEN STEVENS | | (561) 659-8096 EXT 8377 | | (561) 805-6721 | | FAX (561) 653-2692 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2002-03-29 |
|
|
Cont ID |
|
Sent By |
sthyng |
Date |
2003-04-28 |
Time |
11:41 |
Rev Time |
1.00 |
Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2001-10-04 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2001-10-04 |
Time |
14:51 |
Rev Time |
0.25 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|