Plan Review Details - Permit 01091407
Plan Review Stops For Permit 01091407
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2002-01-07 Cont ID  
Sent By jgomez Date 2002-01-07 Time 11:43 Rev Time 0.25
Received By jgomez Date 2002-01-07 Time 11:43 Sent To  
Notes
2002-01-07 00:00:00PRODUCT APPROVAL CHECKLIST:
 1-FRENCH DOOR SITE SPECIFIC PRODUCT
 APPROVAL:
 A)MANUFACTURER'S ENGINEER TO PROVIDE
 ORIGINAL SIGNATURE AND OFFICE ADDRESS
 & PHONE NUMBER AS REQUIRED BY CHAPTER
 471 FLORIDA STATUTES WHEN SUBMITTING
 DOCUMENTS FOR PUBLIC RECORDS.
 B)USE CITY SAMPLE (ATTACHED) WHEN
 SUBMITTING INFORMATION FOR SITE
 SPECIFIC PRODUCT APPROVAL.
 C)PROFESSIONAL ENGINEER OF RECORD TO
 SIGN, SEAL AND DATE THIS SITE SPECIFIC
 FORM AS WELL.
 -INCLUDE ALL HIS INFORMATION AS REQ'D
 BY CHAPTER 471 FLORIDA STATUTES.
 -SPECIFY LOCATION. THIS IS A PRODUCT
 APPROVAL FOR SITE SPECIFIC INSTALLAT'N
 D)CLARIFY WHY THE 2X WOOD BUCK IS NOT
 STRUCTURAL. SEE SEC. 4.2 OF PRODUCT
 APPROVAL INFORMATION SUBMITTED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2001-12-08 Cont ID  
Sent By jgomez Date 2001-12-08 Time 12:22 Rev Time 0.50
Received By jgomez Date 2001-12-08 Time 12:22 Sent To  
Notes
2001-12-08 00:00:00APPROVED WITH PROVISO:
 1-FLOOD ZONE AO. NEED THE ELEVATION
 CERTIFICATE.
 2-NEED ADDITIONAL SOIL BORINGS FOR EACH
 STRUCTURE AS RECOMMENDED ON THE PRE-
 LIMINARY SOIL TEST REPORT.
 3-PROVIDE PRODUCT APPROVAL FOR FRENCH
 DOORS ASSEMBLIES AS SHOWN ON PLANS IF
 OPTION SELECTED.
 4-PROVIDE MANUFACTURER'S CERTIFICATION
 FOR TWO HOUR FIRE RATED CONCRETE BLOCK
 ACCORDING TO THE BLOCK'S EQUIVALENT
 THICKNESS AND AGGREGATES USED. SEE
 SECTION 709.3 SBC 1997.
 5-PROVIDE COMPLETE INFORMATION FOR STORM
 PANELS UNDER A SEPARATE PERMIT.
  
  
 NOTES:
 -DRAWINGS AND COMMENTS TO BE FILED UNDER
 PERMIT #01091407.
 -THESE COMMENTS APPLY TO PERMIT #S:
 01091407, 01091411, 01091413 AND
 01091409.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2001-11-02 Cont ID  
Sent By jgomez Date 2001-11-02 Time 18:17 Rev Time 1.00
Received By jgomez Date 2001-11-02 Time 18:17 Sent To  
Notes
2001-11-02 00:00:00CHECKLIST:
 1-SEE COMMENTS BY PLUMBING. REVISE
 ORIGINAL DRAWINGS TO AVOID DELAYS.
 2-NEED TO RECORD NOTICE OF COMMENCEMENT.
 3-NEED ADDITIONAL SOIL BORINGS FOR EACH
 STRUCTURE AS RECOMMENDED ON THE PRE-
 LIMINARY SOIL TEST REPORT.
 4-PROVIDE PRODUCT APPROVALS FOR:
 A)GARAGE DOORS PRODUCT APPROVAL WAS
 DELETED FROM THE SBCCI LISTING.
 B)WINDOW MULLIONS.
  
 5-CLEARLY INDICATE ON PLANS OPTIONS TO
 BE BUILT AND PROVIDE PRODUCT APPROVALS
 OR CROSS OUT THE OPTIONS.
 6-OWES ADDITIONAL FEES FOR UPDATED VALUE
 AND RADON FEES. PLEASE, PAY ATTACHED
 RECEIPTS AND BRING PAID RECEIPTS.
 7-PROVIDE CERTIFICATION FOR TWO HRFIRE
 RATED CONCRETE BLOCK THAT COMPLIES W/
 SECTION 709.3 SBC 1997.
 NOTE: THIS CERTIFICATION IS PROVIDED
 BY THE CONCRETE MANUFACTURER SINCE
 CERTIFICATION IS GIVEN ACCORDING TO
 THE EQUIVALENT THICKNESS & AGGREGATES
 USED FOR MANUFACTURING THE BLOCK.
 8-PROVIDE COMPLETE INFORMATION FOR STORM
 SHUTTERS OR APPLY FOR SEPARATE PERMIT.
  
  
  
 NOTES:
 -DRAWINGS AND COMMENTS TO BE FILED UNDER
 PERMIT #01091407.
 -THESE COMMENTS APPLY TO PERMIT #S:
 01091407, 01091411, 01091413 AND
 01091409.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2002-09-11 Cont ID  
Sent By btrobaug Date 2002-09-11 Time 15:47 Rev Time 1.00
Received By btrobaug Date 2002-09-11 Time 14:41 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-08-22 Cont ID  
Sent By btrobaug Date 2002-08-22 Time 17:14 Rev Time 0.00
Received By btrobaug Date 2002-08-22 Time 16:51 Sent To  
Notes
2002-08-22 00:00:00PROVISO
 ~~~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
  
 NOTE: PLEASE LIST THE REQ'D BATH(S)
 CIRCUIT(S). PER 210-11-C-3
 MUST BE 20A AND #12AWG.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/659-8096 EXT. 8392

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-10-23 Cont ID  
Sent By dpalmer Date 2001-10-23 Time 13:47 Rev Time 0.00
Received By dpalmer Date 2001-10-23 Time 13:47 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2001-12-06 Cont ID  
Sent By mcarsill Date 2001-12-06 Time 14:48 Rev Time 0.00
Received By mcarsill Date 2001-12-06 Time 14:48 Sent To  
Notes
2001-12-06 00:00:001) WET FIRE HYDRANTS ARE REQUIRED PRIOR
 TO,DURING AND AFTER CONSTRUCTION.
 2) BUILDING ADDRESSES REQUIRED.
 3) PORTABLE FIRE EXTINGUISHERS REQUIRED.
 4) ELECTRIC POWERED SMOKE DETECTORS
 REQUIRED.
 5) EGRESS WINDOWS TO COMPLY WITH
 BUILDING AND FIRE CODE REGULATIONS.
  
 MIKE CARSILLO, CAPTAIN
 659-8096,EXT.8497
 835-2910

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-01-29 Cont ID  
Sent By pkrauss Date 2002-01-29 Time 15:09 Rev Time 0.30
Received By pkrauss Date 2002-01-29 Time 14:10 Sent To  
Notes
2002-01-29 00:00:00MECH REV PERMIT 01091494

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2001-10-08 Cont ID  
Sent By hmoser Date 2001-10-08 Time 08:12 Rev Time 0.33
Received By hmoser Date 2001-10-08 Time 08:12 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2001-12-01 Cont ID  
Sent By kstevens Date 2001-12-01 Time 07:44 Rev Time 0.33
Received By kstevens Date 2001-12-01 Time 07:44 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2001-10-10 Cont ID  
Sent By kstevens Date 2001-10-10 Time 20:16 Rev Time 0.50
Received By kstevens Date 2001-10-10 Time 20:16 Sent To  
Notes
2001-10-10 00:00:00DENIED
 REFERENCE: FAIR HOUSING ACT AMENDED 1998
 DESIGN MANUAL.
  
 1) PAGES 1A & 2 GENERAL NOTES. CHANGE TO
 READ FHA-98 DESIGN MANUAL.
  
 2) MODEL 1527(L) & (R), M/B SHOWS 1'7"
 TO CENTER OF W/C, AND IT SHOULD BE 1'6".
 ALSO SHOW CLEAR FLOOR SPACE FOR LAV.
 PAGES 1A & 1B.
  
 3) IN BATH 2 SHOW CLEAR FLOOR SPACE FOR
 W/C AND LAV. PAGES 1A & 1B.
  
 4) MODEL 1409(L) & (R), M/B SHOWS 1'7"
 TO CENTER OF W/C, AND IT SHOULD BE 1'6"
 ALSO SHOW CLEAR FLOOR SPACE FOR LAV.
 PAGES 1A & 1B.
  
 5) BATH 2 SHOWS 2'8" OPENING FOR W/C.
 2'9" MINIMUM SPACE REQUIRED FOR W/C.
 ALSO SHOW CLEAR FLOOR SPACE FOR W/C AND
 LAV. PAGES 1A & 1B.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT. 8377

Review Stop Z ZONING
Rev No 1 Status P Date 2001-10-02 Cont ID  
Sent By sgraham Date 2001-10-02 Time 14:45 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***