Plan Review Stops For Permit 01091407 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2002-01-07 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2002-01-07 |
Time |
11:43 |
Rev Time |
0.25 |
Received By |
jgomez |
Date |
2002-01-07 |
Time |
11:43 |
Sent To |
|
|
Notes |
2002-01-07 00:00:00 | PRODUCT APPROVAL CHECKLIST: | | 1-FRENCH DOOR SITE SPECIFIC PRODUCT | | APPROVAL: | | A)MANUFACTURER'S ENGINEER TO PROVIDE | | ORIGINAL SIGNATURE AND OFFICE ADDRESS | | & PHONE NUMBER AS REQUIRED BY CHAPTER | | 471 FLORIDA STATUTES WHEN SUBMITTING | | DOCUMENTS FOR PUBLIC RECORDS. | | B)USE CITY SAMPLE (ATTACHED) WHEN | | SUBMITTING INFORMATION FOR SITE | | SPECIFIC PRODUCT APPROVAL. | | C)PROFESSIONAL ENGINEER OF RECORD TO | | SIGN, SEAL AND DATE THIS SITE SPECIFIC | | FORM AS WELL. | | -INCLUDE ALL HIS INFORMATION AS REQ'D | | BY CHAPTER 471 FLORIDA STATUTES. | | -SPECIFY LOCATION. THIS IS A PRODUCT | | APPROVAL FOR SITE SPECIFIC INSTALLAT'N | | D)CLARIFY WHY THE 2X WOOD BUCK IS NOT | | STRUCTURAL. SEE SEC. 4.2 OF PRODUCT | | APPROVAL INFORMATION SUBMITTED. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2001-12-08 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2001-12-08 |
Time |
12:22 |
Rev Time |
0.50 |
Received By |
jgomez |
Date |
2001-12-08 |
Time |
12:22 |
Sent To |
|
|
Notes |
2001-12-08 00:00:00 | APPROVED WITH PROVISO: | | 1-FLOOD ZONE AO. NEED THE ELEVATION | | CERTIFICATE. | | 2-NEED ADDITIONAL SOIL BORINGS FOR EACH | | STRUCTURE AS RECOMMENDED ON THE PRE- | | LIMINARY SOIL TEST REPORT. | | 3-PROVIDE PRODUCT APPROVAL FOR FRENCH | | DOORS ASSEMBLIES AS SHOWN ON PLANS IF | | OPTION SELECTED. | | 4-PROVIDE MANUFACTURER'S CERTIFICATION | | FOR TWO HOUR FIRE RATED CONCRETE BLOCK | | ACCORDING TO THE BLOCK'S EQUIVALENT | | THICKNESS AND AGGREGATES USED. SEE | | SECTION 709.3 SBC 1997. | | 5-PROVIDE COMPLETE INFORMATION FOR STORM | | PANELS UNDER A SEPARATE PERMIT. | | | | | | NOTES: | | -DRAWINGS AND COMMENTS TO BE FILED UNDER | | PERMIT #01091407. | | -THESE COMMENTS APPLY TO PERMIT #S: | | 01091407, 01091411, 01091413 AND | | 01091409. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2001-11-02 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2001-11-02 |
Time |
18:17 |
Rev Time |
1.00 |
Received By |
jgomez |
Date |
2001-11-02 |
Time |
18:17 |
Sent To |
|
|
Notes |
2001-11-02 00:00:00 | CHECKLIST: | | 1-SEE COMMENTS BY PLUMBING. REVISE | | ORIGINAL DRAWINGS TO AVOID DELAYS. | | 2-NEED TO RECORD NOTICE OF COMMENCEMENT. | | 3-NEED ADDITIONAL SOIL BORINGS FOR EACH | | STRUCTURE AS RECOMMENDED ON THE PRE- | | LIMINARY SOIL TEST REPORT. | | 4-PROVIDE PRODUCT APPROVALS FOR: | | A)GARAGE DOORS PRODUCT APPROVAL WAS | | DELETED FROM THE SBCCI LISTING. | | B)WINDOW MULLIONS. | | | | 5-CLEARLY INDICATE ON PLANS OPTIONS TO | | BE BUILT AND PROVIDE PRODUCT APPROVALS | | OR CROSS OUT THE OPTIONS. | | 6-OWES ADDITIONAL FEES FOR UPDATED VALUE | | AND RADON FEES. PLEASE, PAY ATTACHED | | RECEIPTS AND BRING PAID RECEIPTS. | | 7-PROVIDE CERTIFICATION FOR TWO HRFIRE | | RATED CONCRETE BLOCK THAT COMPLIES W/ | | SECTION 709.3 SBC 1997. | | NOTE: THIS CERTIFICATION IS PROVIDED | | BY THE CONCRETE MANUFACTURER SINCE | | CERTIFICATION IS GIVEN ACCORDING TO | | THE EQUIVALENT THICKNESS & AGGREGATES | | USED FOR MANUFACTURING THE BLOCK. | | 8-PROVIDE COMPLETE INFORMATION FOR STORM | | SHUTTERS OR APPLY FOR SEPARATE PERMIT. | | | | | | | | NOTES: | | -DRAWINGS AND COMMENTS TO BE FILED UNDER | | PERMIT #01091407. | | -THESE COMMENTS APPLY TO PERMIT #S: | | 01091407, 01091411, 01091413 AND | | 01091409. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2002-09-11 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2002-09-11 |
Time |
15:47 |
Rev Time |
1.00 |
Received By |
btrobaug |
Date |
2002-09-11 |
Time |
14:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2002-08-22 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2002-08-22 |
Time |
17:14 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2002-08-22 |
Time |
16:51 |
Sent To |
|
|
Notes |
2002-08-22 00:00:00 | PROVISO | | ~~~~~~~ | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | | NOTE: PLEASE LIST THE REQ'D BATH(S) | | CIRCUIT(S). PER 210-11-C-3 | | MUST BE 20A AND #12AWG. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW | | 561/659-8096 EXT. 8392 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2001-10-23 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2001-10-23 |
Time |
13:47 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2001-10-23 |
Time |
13:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2001-12-06 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2001-12-06 |
Time |
14:48 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2001-12-06 |
Time |
14:48 |
Sent To |
|
|
Notes |
2001-12-06 00:00:00 | 1) WET FIRE HYDRANTS ARE REQUIRED PRIOR | | TO,DURING AND AFTER CONSTRUCTION. | | 2) BUILDING ADDRESSES REQUIRED. | | 3) PORTABLE FIRE EXTINGUISHERS REQUIRED. | | 4) ELECTRIC POWERED SMOKE DETECTORS | | REQUIRED. | | 5) EGRESS WINDOWS TO COMPLY WITH | | BUILDING AND FIRE CODE REGULATIONS. | | | | MIKE CARSILLO, CAPTAIN | | 659-8096,EXT.8497 | | 835-2910 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2002-01-29 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2002-01-29 |
Time |
15:09 |
Rev Time |
0.30 |
Received By |
pkrauss |
Date |
2002-01-29 |
Time |
14:10 |
Sent To |
|
|
Notes |
2002-01-29 00:00:00 | MECH REV PERMIT 01091494 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2001-10-08 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2001-10-08 |
Time |
08:12 |
Rev Time |
0.33 |
Received By |
hmoser |
Date |
2001-10-08 |
Time |
08:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2001-12-01 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2001-12-01 |
Time |
07:44 |
Rev Time |
0.33 |
Received By |
kstevens |
Date |
2001-12-01 |
Time |
07:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2001-10-10 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2001-10-10 |
Time |
20:16 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2001-10-10 |
Time |
20:16 |
Sent To |
|
|
Notes |
2001-10-10 00:00:00 | DENIED | | REFERENCE: FAIR HOUSING ACT AMENDED 1998 | | DESIGN MANUAL. | | | | 1) PAGES 1A & 2 GENERAL NOTES. CHANGE TO | | READ FHA-98 DESIGN MANUAL. | | | | 2) MODEL 1527(L) & (R), M/B SHOWS 1'7" | | TO CENTER OF W/C, AND IT SHOULD BE 1'6". | | ALSO SHOW CLEAR FLOOR SPACE FOR LAV. | | PAGES 1A & 1B. | | | | 3) IN BATH 2 SHOW CLEAR FLOOR SPACE FOR | | W/C AND LAV. PAGES 1A & 1B. | | | | 4) MODEL 1409(L) & (R), M/B SHOWS 1'7" | | TO CENTER OF W/C, AND IT SHOULD BE 1'6" | | ALSO SHOW CLEAR FLOOR SPACE FOR LAV. | | PAGES 1A & 1B. | | | | 5) BATH 2 SHOWS 2'8" OPENING FOR W/C. | | 2'9" MINIMUM SPACE REQUIRED FOR W/C. | | ALSO SHOW CLEAR FLOOR SPACE FOR W/C AND | | LAV. PAGES 1A & 1B. | | | | REVIEW BY KEN STEVENS | | (561) 659-8096 EXT. 8377 |
|
|