Plan Review Details - Permit 01091318
Plan Review Stops For Permit 01091318
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2002-01-07 Cont ID  
Sent By jgomez Date 2002-01-07 Time 13:20 Rev Time 0.25
Received By jgomez Date 2002-01-07 Time 13:20 Sent To  
Notes
2002-01-07 00:00:00PRODUCT APPROVAL CHECKLIST:
 1-FRENCH DOOR SITE SPECIFIC PRODUCT
 APPROVAL:
 A)MANUFACTURER'S ENGINEER TO PROVIDE
 ORIGINAL SIGNATURE AND OFFICE ADDRESS
 & PHONE NUMBER AS REQUIRED BY CHAPTER
 471 FLORIDA STATUTES WHEN SUBMITTING
 DOCUMENTS FOR PUBLIC RECORDS.
 B)USE CITY SAMPLE (ATTACHED) WHEN
 SUBMITTING INFORMATION FOR SITE
 SPECIFIC PRODUCT APPROVAL.
 C)PROFESSIONAL ENGINEER OF RECORD NEED
 TO SIGN, SEAL & DATE THIS SPECIFIC
 PRODUCT APPROVAL FORM AS WELL.
 -INCLUDE ALL HIS INFORMATION AS REQ'D
 BY CHAPTER 471 FLORIDA STATUTES.
 -SPECIFY LOCATION. THIS IS A SITE
 SPECIFIC INSTALLATION.
 D)CLARIFY WHY THE 2X WOOD BUCK IS NOT
 CONSIDERED STRUCTURAL. SEE SECTION 4.2
 OF PRODUCT APPROVAL INFO. SUBMITTED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2001-12-04 Cont ID  
Sent By jgomez Date 2001-12-04 Time 10:49 Rev Time 1.00
Received By jgomez Date 2001-12-04 Time 10:49 Sent To  
Notes
2001-12-04 00:00:00APPROVED WITH PROVISO:
 1-FLOOD ZONE AO: NEED THE ELEVATION
 CERTIFICATE.
 2-NEED ADDITIONAL SOIL BORINGS FOR EACH
 STRUCTURE AS RECOMMENDED ON THE PRE-
 LIMINARY SOIL TEST REPORT.
 3-PROVIDE PRODUCT APPROVAL FOR FRENCH
 DOORS AS SHOWN ON PLANS IF OPTION
 IS SELECTED.
 4-PROVIDE MANUFACTURER'S CERTIFICATION
 FOR TWO HR FIRE RATED CONCRETE BLOCK
 ACCORDING TO THE BLOCK EQUIVALENT
 THICKNESS AND AGGREGATES USED. SECTION
 709.3 SBC 1997.
 5-PROVIDE COMPLETE INFORMATION FOR STORM
 PANELS UNDER A SEPARATE PERMIT.
  
  
 NOTES:
 -DRAWINGS AND COMMENTS TO BE FILED UNDER
 PERMIT #01091318.
 -THESE COMMENTS APPLY TO PERMIT #S:
 01091318, 01091320, 01091322, 01091324,
 01091326 AND 01091328.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2001-10-27 Cont ID  
Sent By jgomez Date 2001-10-27 Time 13:09 Rev Time 1.00
Received By jgomez Date 2001-10-27 Time 13:09 Sent To  
Notes
2001-10-27 00:00:00CHECKLIST:
 1-SEE COMMENTS BY PLUMBING. CORRECT
 ORIGINAL DRAWINGS TO AVOID DELAYS.
 2-NEED RECORDED NOTICE OF COMMENCEMENT.
 3-WILL NEED ADDITIONAL SOIL BORINGS FOR
 EACH STRUCTURE AS RECOMMENDED ON THE
 PRELIMINARY SOIL TEST REPORT.
 4-PROVIDE PRODUCT APPROVAL FOR:
 A)GARAGE DOORS: ONE SUBMITTED WAS
 DELETED FROM SBCCI LISTING.
 B)WINDOW MULLIONS.
  
 5-CLEARLY INDICATE ON PLANS OPTIONS TO
 BE BUILT AND PROVIDE PRODUCT APPROVALS
 OR CROSS OUT OPTIONS ON PLANS.
 6-OWES ADDITIONAL FEES FOR UPDATED VALUE
 AND RADON FEES. PLEASE PAY ATTACHED
 RECEIPTS AND BRING PAID RECEIPTS.
 7-PROVIDE CERTIFICATION FOR TWO HR FIRE
 RATED CONCRETE BLOCK THAT COMPLIES W/
 SECTION 709.3 SBC 1997 ACCORDING TO
 THE EQUIVALENT THICKNESS.
 8-PROVIDE COMPLETE INFORMATION FOR STORM
 PANELS OR APPLY FOR A SEPARATE PERMIT.
  
  
 NOTES:
 -DRAWINGS AND COMMENTS TO BE FILED UNDER
 PERMIT #01091318.
 -THESE COMMENTS APPLY TO PERMIT #S:
 01091318, 01091320, 01091322, 01091324,
 01091326 AND 01091328.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-05-02 Cont ID  
Sent By btrobaug Date 2002-05-02 Time 07:25 Rev Time 0.00
Received By btrobaug Date 2002-05-02 Time 07:15 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-10-09 Cont ID  
Sent By dpalmer Date 2001-10-09 Time 22:48 Rev Time 0.00
Received By dpalmer Date 2001-10-09 Time 22:48 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2001-10-17 Cont ID  
Sent By mcarsill Date 2001-10-17 Time 09:31 Rev Time 0.00
Received By mcarsill Date 2001-10-17 Time 09:31 Sent To  
Notes
2001-10-17 00:00:001) WET FIRE HYDRANTS ARE REQUIRED PRIOR
 TO,DURING AND AFTER CONSTRUCTION.
 2) BUILDING ADDRESSES REQUIRED.
 3) ELECTRIC POWERED SMOKE DETECTORS
 REQUIRED.
 4) PORTABLE FIRE EXTINGUISHERS REQUIRED.
 5) EGRESS WINDOWS TO COMPLY WITH
 BUILDING AND FIRE CODES.
  
 MIKE CARSILLO, CAPTAIN
 659-8096,EXT.8497
 835-2910

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-03-26 Cont ID  
Sent By pkrauss Date 2002-03-26 Time 15:59 Rev Time 0.25
Received By pkrauss Date   Time   Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2001-12-04 Cont ID  
Sent By jgomez Date 2001-12-04 Time 14:39 Rev Time 0.00
Received By jgomez Date 2001-12-04 Time 14:39 Sent To  
Notes
2001-12-04 00:00:00APPROVED BY HAROLD MOSER.

Review Stop P PLUMBING
Rev No 2 Status P Date 2001-12-01 Cont ID  
Sent By kstevens Date 2001-12-01 Time 08:12 Rev Time 0.33
Received By kstevens Date 2001-12-01 Time 08:12 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2001-10-02 Cont ID  
Sent By jleech Date 2001-10-02 Time 17:09 Rev Time 1.00
Received By jleech Date 2001-10-02 Time 17:09 Sent To  
Notes
2001-10-02 00:00:00PLUMBING DENIED;
 1.FHA DIMENSIONS FOR W/C ARE NOT 19".
 PLEASE MAKE CHANGE TO MASTER PLANS.
 2.PAGE 2 SANITARY FISER DIAGRAM. OPT.
 L.T. REQUIRES A VENT. PLEASE MAKE
 CHANGES TO MASTER PLANS.
 PLUMBING PLAN REVIEW BY;
 JLEECH
 659-8096 EXT.8369

Review Stop Z ZONING
Rev No 1 Status P Date 2001-10-02 Cont ID  
Sent By sgraham Date 2001-10-02 Time 14:45 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***