Plan Review Details - Permit 01091140
Plan Review Stops For Permit 01091140
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2002-01-07 Cont ID  
Sent By jgomez Date 2002-01-07 Time 13:45 Rev Time 0.25
Received By jgomez Date 2002-01-07 Time 13:45 Sent To  
Notes
2002-01-07 00:00:00PRODUCT APPROVAL CHECKLIST:
 1-FRENCH DOOR SITE SPECIFIC PRODUCT
 APPROVAL:
 A)MANUFACTURER'S ENGINEER TO PROVIDE
 ORIGINAL SIGNATURE AND OFFICE ADDRESS
 & PHONE NUMBER AS REQUIRED BY CHAPTER
 471 FLORIDA STATUTES WHEN SUBMITTING
 DOCUMENTS FOR PUBLIC RECORDS.
 B)USE CITY SAMPLE (ATTACHED) WHEN
 SUBMITTING INFORMATION FOR SITE
 SPECIFIC PRODUCT APPROVAL.
 C)PROFESSIONAL ENGINEER OF RECORD NEED
 TO SIGN, SEAL & DATE THIS SPECIFIC
 PRODUCT APPROVAL FORM AS WELL.
 -INCLUDE ALL HIS INFORMATION AS REQ'D
 BY CHAPTER 471 FLORIDA STATUTES.
 -SPECIFY LOCATION. THIS IS A SITE
 SPECIFIC INSTALLATION.
 D)CLARIFY WHY THE 2X WOOD BUCK IS NOT
 CONSIDERED STRUCTURAL. SEE SECTION 4.2
 OF PRODUCT APPROVAL INFO. SUBMITTED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2001-12-04 Cont ID  
Sent By jgomez Date 2001-12-04 Time 17:42 Rev Time 1.00
Received By jgomez Date 2001-12-04 Time 17:42 Sent To  
Notes
2001-12-04 00:00:00APPROVED WITH PROVISO:
 1-FLOOD ZONE AO: NEED THE ELEVATION
 CERTIFICATE.
 2-NEED ADDITIONAL SOIL BORINGS FOR EACH
 STRUCTURE AS RECOMMENDED ON THE PRE-
 LIMINARY SOIL TEST REPORT.
 3-PROVIDE PRODUCT APPROVAL FOR FRENCH
 DOORS AS SHOWN ON PLANS IF OPTION
 IS SELECTED.
 4-PROVIDE MANUFACTURER'S CERTIFICATION
 FOR TWO HR FIRE RATED CONCRETE BLOCK
 ACCORDING TO THE BLOCK'S EQUIVALENT
 THICKNESS AND AGGREGATES USED. SEE
 SECTION 709.3 SBC 1997.
 5-PROVIDE COMPLETE INFORMATION FOR STORM
 PANELS UNDER A SEPARATE PERMIT.
  
  
  
 NOTES:
 -DRAWINGS TO BE FILED UNDER PERMIT #
 01091140.
 -THESE COMMENTS APPLY TO PERMIT #S:
 01091140, 01091144, 01091147, 01091148,
 01091146 AND 01091143.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2001-10-17 Cont ID  
Sent By jgomez Date 2001-10-17 Time 18:43 Rev Time 1.00
Received By jgomez Date 2001-10-17 Time 18:43 Sent To  
Notes
2001-10-17 00:00:00CHECKLIST:
 1-SEE COMMENTS BY PLUMBING. SAME COMMENT
 WAS ADDRESSED SEVERAL TIMES BEFORE.
 2-NEED NOTICE OF COMMENCEMENT.
 3-WILL NEED ADDITIONAL SOIL BORINGS FOR
 EACH STRUCTURE AS RECOMMENDED ON THE
 PRELIMINARY SOIL TEST REPORT.
 4-PROVIDE PRODUCT APPROVAL FOR:
 A)GARAGE DOORS PRODUCT APPROVAL WAS
 DELETED FROM SBCCI.
 B)WINDOW MULLIONS.
  
 5-CLEARLY INDICATE OPTIONS TO BE BUILT
 AND PROVIDE CORRESPONDING PRODUCT
 APPROVAL OR CROSS OUT SHEET.
 6-OWES ADDITIONAL FEES FOR UPDATED
 VALUATION AND RADON FEES. PLEASE, PAY
 ATTACHED RECEIPTS.
 7-PROVIDE CERTIFICATION FOR 2 HR FIRE
 RATED CONCRETE BLOCK USED TO SEPARATE
 TOWNHOUSES. SEE SEC. 709.3 SBC 1997.
 8-PROVIDE COMPLETE INFORMATION FOR STORM
 PANELS OR APPLY FOR SEPARATE PERMIT.
  
 NOTES:
 -THESE COMMENTS APPLY TO PERMIT #S:
 01091140, 01091144, 01091147, 01091148,
 01091146 AND 01091143.
 -DRAWINGS TO BE FILED UNDER PERMIT #
 01091140.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-03-25 Cont ID  
Sent By btrobaug Date 2002-03-25 Time 15:21 Rev Time 0.00
Received By btrobaug Date 2002-03-25 Time 14:02 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-10-10 Cont ID  
Sent By dpalmer Date 2001-10-10 Time 07:15 Rev Time 0.00
Received By dpalmer Date 2001-10-10 Time 07:15 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2001-10-16 Cont ID  
Sent By mcarsill Date 2001-10-16 Time 15:42 Rev Time 0.00
Received By mcarsill Date 2001-10-16 Time 15:41 Sent To  
Notes
2001-10-16 00:00:001) WET FIRE HYDRANTS ARE REQUIRED PRIOR
 TO,DURING AND AFTER CONSTRUCTION.
 2) BUILDING ADDRESSES REQUIRED.
 3) ELECTRIC POWERED SMOKE DETECTORS
 REQUIRED.
 4) PORTABLE FIRE EXTINGUISHERS REQUIRED.
 5) EGRESS WINDOWS TO COMPLY WITH
 BUILDING AND FIRE CODE REGULATIONS.
  
 MIKE CARSILLO, CAPTAIN
 659-8096,EXT.8497
 835-2910

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-03-08 Cont ID  
Sent By pkrauss Date 2002-03-08 Time 15:29 Rev Time 0.30
Received By pkrauss Date 2002-03-08 Time 15:20 Sent To  
Notes
2002-03-08 00:00:00THIS SUBMITTAL WAS NOT A REVISION.
 APPROVED BY H. MOSER 10-3-01 PLANS WHERE
 NOT STAMPED.OKAY PER H. MOSER.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2001-10-03 Cont ID  
Sent By hmoser Date 2001-10-03 Time 20:05 Rev Time 0.33
Received By hmoser Date 2001-10-03 Time 20:04 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2001-12-01 Cont ID  
Sent By kstevens Date 2001-12-01 Time 07:28 Rev Time 0.33
Received By kstevens Date 2001-12-01 Time 07:28 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2001-11-05 Cont ID  
Sent By kstevens Date 2001-11-05 Time 17:15 Rev Time 0.50
Received By kstevens Date 2001-11-05 Time 17:15 Sent To  
Notes
2001-11-05 00:00:00DENIED
 REFERENCE: SPC-94 - FHA AMEND 98 DESIGN
 MANUAL
 1) PAGES 1, 1A, 1B MODEL 1527 (L)(R).
 M/BATH SHOWS 1'7" TO C/L OF W/C AND IT
 SHOULD BE 1'6". ALSO SHOW CLEAR FLOOR
 SPACE FOR LAV.
 2) PAGES 1, 1A, 1B MODEL 1527 (L)(R).
 2ND BATH SHOW CLEAR FLOOR SPACE FOR W/C
 AND LAV.
 3) PAGES 1, 1A, 1B MODEL 1409 (L)(R).
 M/BATH SHOWS 1'7" TO C/L OF W/C AND IT
 SHOULD BE 1'6". ALSO SHOW CLEAR FLOOR
 SPACE FOR LAV.
 4) PAGES 1, 1A, 1B MODEL 1409 (L)(R).
 2ND BATH SHOWS 2'8" OPENING FOR W/C, AND
 MINIMUM OPENING REQUIRED IS 2'9". ALSO
 SHOW CLEAR FLOOR SPACE FOR W/C AND LAV.
 5) PAGES 1, 1A, 1B MODEL 1357 (L)(R).
 M/BATH SHOWS 1'7" TO C/L OF W/C AND IT
 SHOULD BE 1'6". ALSO SHOW CLEAR FLOOR
 SPACE FOR LAV.
 2ND BATH SHOW CLEAR FLOOR SPACE FOR W/C
 AND LAV.
 6) PAGES 1, 1A, 1B GENERAL NOTES #11 -
 CHANGE TO READ FHA AMENDED 98 DESIGN
 MANUAL.
 7) PAGE 2 MODELS 1409 (L)(R) AND 1527
 (L)(R) PLUMBING RISERS. OPT LAUNDRY TRAY
 IS NOT VENTED PROPERLY. SHOW VENT FOR
 THESE FIXTURES.
 8) CORRRECTIONS FOR SIGNED AND SEALED
 PLANS SHALL BE SIGNED AND SEALED ALSO.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop P PLUMBING
Rev No 1 Status F Date 2001-10-02 Cont ID  
Sent By jleech Date 2001-10-02 Time 18:01 Rev Time 1.00
Received By jleech Date 2001-10-02 Time 18:01 Sent To  
Notes
2001-10-02 00:00:00PLUMBING DENIED;
 1.FHA DIMENSIONS FOR W/C ARE NOT CORRECT
 18" FROM TUB NOT 19". PLEASE MAKE
 CHANGES TO MASTER PLANS.
 2.PAGE 2 SANITARY RISER DIAGRAM. OPT.
 L.T. REQUIRES A VENT. PLEASE MAKE
 CHANGES TO MASTER PLANS.

Review Stop Z ZONING
Rev No 1 Status P Date 2001-10-02 Cont ID  
Sent By sgraham Date 2001-10-02 Time 14:41 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***