Plan Review Details - Permit 01090910
Plan Review Stops For Permit 01090910
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2002-05-14 Cont ID  
Sent By jgomez Date 2002-05-14 Time 09:25 Rev Time 0.25
Received By jgomez Date 2002-05-14 Time 09:25 Sent To  
Notes
2002-05-14 00:00:00TRUSS DRAWINGS REVIEW. TRUSS ENGINEER
 SIGNED, SEALED AND DATED DOCUMENTS AS
 REQUIRED BY CHAPTER 471 FLORIDA STATUTES

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2002-05-09 Cont ID  
Sent By jgomez Date 2002-05-09 Time 18:31 Rev Time 0.25
Received By jgomez Date 2002-05-09 Time 18:31 Sent To  
Notes
2002-05-09 00:00:00TRUSS DRAWINGS SECOND CHECKLIST:
 1-ENGINEER FAILURE TO PROVIDE ORIGINAL
 EMBOSSED SEAL AS REQUIRED BY CHAPTER
 471 OF FLORIDA STATUTES.
 2-TRUSS ENGINEER TO PROVIDE ORIGINAL
 SIGNATURE, SEAL AND DATE TO TRUSS
 PLAN AS REQUIRED BY CHAPTER 471 OF
 FLORIDA STATUTES.
 3-RE-SUBMITTAL FEES WILL BE CHARGED
 WHEN RESUBMITTING TRUSS PACKAGE.
 SEE ATTACHED FOR RESUBMITTAL FEES

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2002-05-01 Cont ID  
Sent By jgomez Date 2002-05-01 Time 13:32 Rev Time 0.25
Received By jgomez Date 2002-05-01 Time 13:32 Sent To  
Notes
2002-05-01 00:00:00TRUSS DRAWINGS CHECKLIST:
  
 1-ENGINEER FAILURE TO PROVIDE ORIGINAL
 SEAL, SIGNATURE AND DATE ON COVER/
 INDEX PAGE AS REQUIRED BY 61G15-31.003
 LINE (2).

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2001-11-01 Cont ID  
Sent By jgomez Date 2001-11-01 Time 16:20 Rev Time 0.50
Received By jgomez Date 2001-11-01 Time 16:20 Sent To  
Notes
2001-11-01 00:00:00APPROVED WITH PROVISO:
  
 1-FLOOD ZONE AO. WILL NEED TO PROVIDE
 THE ELEVATION CERTIFICATE.
 2-PROVIDE COMPLETE INFORMATION FOR STORM
 SHUTTERS UNDER A SEPARATE PERMIT.
  
  
 NOTES:
 -DRAWINGS TO BE FILED UNDER PERMIT #:
 01090910.
 -THESE COMMENTS APPLY TO PERMIT #S:
 01090910, 01090913, 01090916, 01090915,
 01090926 AND 01090920.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2001-10-16 Cont ID  
Sent By jgomez Date 2001-10-16 Time 10:20 Rev Time 1.00
Received By jgomez Date 2001-10-16 Time 10:19 Sent To  
Notes
2001-10-16 00:00:00CHECKLIST:
 1-NEED TO RECORD NOTICE OF COMMENCEMENT.
 2-OWNER/AGENT TO SIGN AND DATE ALL THE
 ENERGY CALCULATIONS.
 3-PROVIDE PRODUCT APPROVAL FOR:
 A)GARAGE DOORS PRODUCT APPROVAL WAS
 DELETED BY SBCCI.
 B)WINDOW MULLIONS.
 4-PROVIDE CERTIFICATION FOR 2 HOUR FIRE
 RATED CONCRETE BLOCK TO BE USED BET.
 TOWNHOUSES.
 5-CLEARLY INDICATE ON PLANS OPTIONS THAT
 WILL APPLY FOR THIS BUILDING PERMIT
 AND PROVIDE THE REQUIRED PRODUCT
 APPROVALS. OTHERWISE, PLEASE CROSS OUT
 THE OPTIONS PAGE.
 6-PROVIDE COMPLETE INFORMATION FOR
 STORM PANELS OR APLY FOR SEPARATE
 PERMIT.
 7-PLEASE PAY ATTACHED RECEIPTS FOR
 UPDATED BUILDING VALUE AND RADON FEES.
  
  
  
 NOTES:
 -DRAWINGS TO BE FILED UNDER PERMIT #
 01090910.
 -THESE COMMENTS APPLY TO PERMIT #S:
 01090910, 01090913, 01090916, 01090915,
 01090926 AND 01090920.

Review Stop E ELECTRICAL
Rev No 2 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-10-03 Cont ID  
Sent By dpalmer Date 2001-10-03 Time 23:37 Rev Time 0.00
Received By dpalmer Date 2001-10-03 Time 23:37 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2001-10-16 Cont ID  
Sent By mcarsill Date 2001-10-16 Time 16:53 Rev Time 0.00
Received By mcarsill Date 2001-10-16 Time 16:53 Sent To  
Notes
2001-10-16 00:00:001) WET FIRE HYDRANTS ARE REQUIRED PRIOR
 TO,DURING AND AFTER CONSTRUCTION.
 2) BUILDING ADDRESSES REQUIRED.
 3) ELECTRIC POWERED SMOKE DETECTORS
 REQUIRED.
 4) PORTABLE FIRE EXTINGUISHERS REQUIRED.
 5) EGRESS WINDOWS TO COMPLY WITH
 BUILDING AND FIRE CODE REQUIREMENTS.
  
 MIKE CARSILLO, CAPTAIN
 659-8096,EXT.8497
 835-2910

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-01-29 Cont ID  
Sent By pkrauss Date 2002-01-29 Time 13:34 Rev Time 0.35
Received By pkrauss Date 2002-01-29 Time 13:14 Sent To  
Notes
2002-01-29 00:00:00MECH REV PERMIT 01091045

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2001-09-29 Cont ID  
Sent By hmoser Date 2001-09-29 Time 07:45 Rev Time 0.33
Received By hmoser Date 2001-09-29 Time 07:44 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2001-09-25 Cont ID  
Sent By jleech Date 2001-09-25 Time 18:40 Rev Time 0.25
Received By jleech Date 2001-09-25 Time 18:40 Sent To  
Notes
2001-09-25 00:00:00PROVISO;
 1.W/C SHALL BE 1'-6" OFF SHOWER NOT 1'-7
 2.L.T. MUST BE VENTED IF INSTALLED.

Review Stop Z ZONING
Rev No 1 Status P Date 2001-09-24 Cont ID  
Sent By sgraham Date 2001-09-24 Time 10:06 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***