Plan Review Details - Permit 01090908
Plan Review Stops For Permit 01090908
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2002-02-14 Cont ID  
Sent By jgomez Date 2002-02-14 Time 17:57 Rev Time 0.33
Received By jgomez Date 2002-02-14 Time 17:57 Sent To  
Notes
2002-02-14 00:00:00TRUSS DRAWINGS REVIEW.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2001-12-08 Cont ID  
Sent By jgomez Date 2001-12-08 Time 15:22 Rev Time 0.50
Received By jgomez Date 2001-12-08 Time 15:22 Sent To  
Notes
2001-12-08 00:00:00APPROVED WITH PROVISO:
 1-FLOOD ZONE AO. NEED THE ELEVATION
 CERTIFICATE.
 2-NEED ADDITIONAL SOIL BORINGS FOR EACH
 STRUCTURE AS RECOMMENDED ON THE PRE-
 LIMINARY SOIL TEST REPORT.
 3-PROVIDE PRODUCT APPROVAL FOR FRENCH
 DOORS ASSEMBLIES AS SHOWN ON PLANS IF
 OPTION SELECTED.
 4-PROVIDE MANUFACTURER'S CERTIFICATION
 FOR TWO HOUR FIRE RATED CONCRETE BLOCK
 ACCORDING TO THE BLOCK'S EQUIVALENT
 THICKNESS AND AGGREGATES USED. SEE
 SECTION 709.3 SBC 1997.
 5-PROVIDE COMPLETE INFORMATION FOR STORM
 PANELS UNDER A SEPARATE PERMIT.
 6-TRUSS DRAWINGS:
 -UPDATE ALL GENERAL TRUSS DETAILS. USE
 ASCE 7-95 FOR 140 MPH, NOT ASCE 7-93.
 SEE COMMENTS ON TRUSSES.
  
  
 NOTES:
 -DRAWINGS AND COMMENTS TO BE FILED UNDER
 PERMIT #01090908.
 -THESE COMMENTS APPLY TO PERMIT #S:
 01090908, 01090911, 01090914, 01090918,
 01090922 AND 01090924.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2001-10-25 Cont ID  
Sent By jgomez Date 2001-10-25 Time 12:04 Rev Time 1.00
Received By jgomez Date 2001-10-25 Time 12:04 Sent To  
Notes
2001-10-25 00:00:00CHECKLIST:
 1-SEE COMMENTS BY PLUMBING. CORRECT
 ORIGINAL DRAWINGS TO AVOID DELAYS.
 2-NEED RECORDED NOTICE OF COMMENCEMENT.
 3-WILL NEED ADDITIONAL SOIL BORINGS FOR
 EACH STRUCTURE AS RECOMMENDED ON THE
 PRELIMINARY SOIL TEST REPORT.
 4-PROVIDE PRODUCT APPROVAL FOR:
 A)GARAGE DOORS. ONE SUBMITTED WAS
 DELETED FROM SBCCI LISTING.
 B)WINDOW MULLIONS.
  
 5-CLEARLY INDICATE ON PLANS OPTIONS TO
 BE BUILT AND PROVIDE PRODUCT APPROVALS
 OR CROSS OUT OPTIONS ON PLANS.
 6-OWES ADDITIONAL FEES FOR UPDATED VALUE
 AND RADON FEES. PLEASE PAY ATTACHED
 RECEIPTS AND BRING PAID RECEIPTS.
 7-PROVIDE CERTIFICATION FOR TWO HR FIRE
 RATED CONCRETE BLOCK THAT COMPLIES
 WITH SECTION 709.3 SBC 1997 ACCORDING
 TO THE EQUIVALENT THICKNESS.
 8-PROVIDE COMPLETE INFORMATION FOR STORM
 PANELS OR APPLY FOR A SEPARATE PERMIT.
  
  
  
 NOTES:
 -DRAWINGS AND COMMENTS TO BE FILED UNDER
 PERMIT #01090908.
 -THESE COMMENTS APPLY TO PERMIT #S:
 01090908, 01090911, 01090914, 01090918
 01090922 AND 01090924.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-08-21 Cont ID  
Sent By btrobaug Date 2002-08-21 Time 15:00 Rev Time 0.00
Received By btrobaug Date 2002-08-21 Time 14:01 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-10-22 Cont ID  
Sent By dpalmer Date 2001-10-22 Time 23:05 Rev Time 0.00
Received By dpalmer Date 2001-10-22 Time 23:05 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2001-12-06 Cont ID  
Sent By mcarsill Date 2001-12-06 Time 16:24 Rev Time 0.00
Received By mcarsill Date 2001-12-06 Time 16:24 Sent To  
Notes
2001-12-06 00:00:001) WET FIRE HYDRANTS ARE REQUIRED PRIOR
 TO,DURING AND AFTER CONSTRUCTION.
 2) BUILDING ADDRESSES REQUIRED.
 3) PORTABLE FIRE EXTINGUISHERS REQUIRED.
 4) ELECTRIC POWERED SMOKE DETECTORS
 REQUIRED.
 5) EGRESS WINDOWS TO COMPLY WITH
 BUILDING AND FIRE CODE REQUIREMENTS.
  
 MIKE CARSILLO, CAPTAIN
 659-8096,EXT.8497
 835-2910

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2001-10-13 Cont ID  
Sent By hmoser Date 2001-10-13 Time 11:02 Rev Time 0.33
Received By hmoser Date 2001-10-13 Time 11:01 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2001-11-30 Cont ID  
Sent By kstevens Date 2001-11-30 Time 18:34 Rev Time 0.33
Received By kstevens Date 2001-11-30 Time 18:34 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2001-10-17 Cont ID  
Sent By jleech Date 2001-10-17 Time 17:52 Rev Time 1.00
Received By jleech Date 2001-10-17 Time 17:52 Sent To  
Notes
2001-10-17 00:00:00DENIED;
 1.PAGE 1A &2 GENERAL NOTES. CHANGE TO
 READ FHA-98 DESIGN MANUAL.
 2.MODEL 1527 M/B SHOWS 1'7" TO CENTER OF
 W/C AND IT SHOULD BE 1'6" ALSO SHOW
 CLEAR FLOOR SPACE FOR LAV. PAGES 1A&B.
 3.IN BATH 2 SHOW CLEAR FLOOR SPACE FOR
 W/C AND LAV. PAGE1A &B.
 4.MODEL 1409, M/B SHOWS 1'7" TO CENTER
 OF W/C AND IT SHOULD BE 1'6". ALSO
 SHOW CLEAR FLOOR SPACE FOR LAV. PAGES
 1A & B.
 5.BATH 2 SHOWS 2' 8" OPENING FOR W/C.
 2'9" MIN. SPACE REQ. FOR W/C AND LAV.
 PAGES 1A & B.
 6.PAGE 2 RISER DIAGRAM MODEL 1527 & 1409
 SHOW VENT FOR OPT. L.T.

Review Stop Z ZONING
Rev No 1 Status P Date 2001-10-02 Cont ID  
Sent By sgraham Date 2001-10-02 Time 15:00 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***